Ingredients : gms/lit.
Pancreatic Digest of Casein 17.00
Soya Peptone 3.00
Sodium chloride 5.00
Dipotassium Hydrogen Phosphate 2.50
Glucose 2.50
Bile Salts No.3 1.50
Final pH (at 25°C) : 7.3 + 0.2

Directions :
Suspend 31.5 grams in 1000 ml distilled water. Heat to boiling to dissolve the medium completely. Distribute 250 ml into flasks and sterilize by autoclaving at 15 lbs pressure (121°C) for 15 minutes. Cool to 45-50oC and to each 250 ml flask add, under aseptic conditions Novobiocin supplement reconstituted with 2.0 ml of sterile distilled water. Final concentration should be 20.0
mg/liter

Principle :
The combination of Pancreatic Digest of Casein and Soya peptone makes these media nutritious by providing amino acids and long chain peptides for the growth of microorganisms. Dextrose and dipotassium phosphate serves as the carbohydrate source and the buffer in the medium. Sodium chloride maintains osmotic balance in both the media

Packing

500 G

Recently Viewed

DNA and RNA Purification

Pipette series Assist

The Assist series pipettes are single or 8, 12 channel variable volume pipettes designed to measure and transfer volumes from 0.1 μl to 10000 μl depending on the model.

This product has multiple variants. The options may be chosen on the product page

Rockers, Shakers and Rotators

Multi–functional Orbital Shaker PSU-20i

Shaker PSU-20i provides three motion types: orbital, reciprocal and vibrating, which can be performed separately, pairwise and   sequentially in repeated cycles. Shaker is designed for applications both in small specialized laboratories and in large multidisciplinary laboratories. PSU-20i is an ideal instrument for laboratories conducting research in biopharmaceutics and biomedicine.

Inteliwasher 3D-IW8 series microplate washer is designed for washing various types of standard 96-well microtitre plates, microstrips as well as microarrays on FastFRAME (rectangular well shape). It is suitable for washing wells with different bottom shapes: flat, U-shape and V-shape. The unit is fully programmable ensuring multi-step solution ripening, aspiration (aspiration, combination of  aspiration/liquid dispensing and soaking, as well as soaking cycle during a particular period of time). Dispense system of liquid dosage for each channel separately.

Reagents

GLYCINE LR

Aminoacetic acid; Aminoethanoic acid; Glycocoll

Blocks

Block B10-13

Ø13 mm x 10 sockets, flat bottom, depth 30 mm.

nSAFE Safety Cabinets

nSAFE Class II XL

The n-Safe XL cabinets offer extraordinary inner dimensions, whenever the working space of a standard cabinet isn ́t sufficient: XL cabinets come with an interior height of 1000mm and an interior depth of 900 mm. The complete front can be opened to easily fit in large devices, e.g. a pipetting robot.

This product has multiple variants. The options may be chosen on the product page

This additive is used in conjunction with Veratox for Gliadin and Alert for Gliadin in evaluating samples containing high levels of tannins, cocoa or dark chocolate.

Products Best Selling

Sterile TPP TubeSpin® Bioreactor vessel, 50 ml, with pH and O2 sensor spots, 1 pce.

For the separation and purification of samples of cells, macromolecular proteins, blood, body fluids, DNA/RNA, plasmids, bacteria and viruses.

20 × 0.2 ml microtubes + 12 × 1.5 ml microtubes

The ES-20 is a compact bench–top Shaker–Incubator used for mixing of biological liquids as well as for incubation and cultivation of biological liquids according to the operator set program

Applicable for storing wholeblood, medicines, biological products and other laboratory products that need to be stored at 4℃. Suitable for the storage of blood and blood articles in areas that have power shortages.

LN2 backup cooling system is an independent refrigeration system for a ULT freezer. When there is a loss of power or the temperature of the freezer rises to the high alarm set point, the LN2 backup system can be automatically activated to inject LN2 into the chamber to maintain the freezer temperature. The backup system operates on a rechargeable battery when there is a loss of main power.

A-12, adapter for work with tubes which are 12 mm in external diameter.

Products Favourite

LN2 backup cooling system is an independent refrigeration system for a ULT freezer. When there is a loss of power or the temperature of the freezer rises to the high alarm set point, the LN2 backup system can be automatically activated to inject LN2 into the chamber to maintain the freezer temperature. The backup system operates on a rechargeable battery when there is a loss of main power.

A-12, adapter for work with tubes which are 12 mm in external diameter.

The ES-20 is a compact bench–top Shaker–Incubator used for mixing of biological liquids as well as for incubation and cultivation of biological liquids according to the operator set program

For the separation and purification of samples of cells, macromolecular proteins, blood, body fluids, DNA/RNA, plasmids, bacteria and viruses.

20 × 0.2 ml microtubes + 12 × 1.5 ml microtubes

Sterile TPP TubeSpin® Bioreactor vessel, 50 ml, with pH and O2 sensor spots, 1 pce.

Applicable for blood stations, hospitals, CDC's, scientific research institutes, chemical industry and other related industries. The -30°C Biomedical Freezer can cryopreserve plasma, biological products, components, materials, and other items that need to be kept at low temperature.

This product has multiple variants. The options may be chosen on the product page

SOYBEAN CASEIN DIGEST MEDIUM (trypto casein soja)

SKU: DM2740500 Category: