RTS-8 plus is a personal bioreactor that utilizes patented Reverse-Spin® technology that applies non-invasive, mechanically driven, low energy consumption, innovative type of agitation where cell suspension is mixed by the single-use falcon bioreactor tube rotation around its axis with a change of direction of rotation motion resulting in highly efficient mixing and oxygenation for aerobic cultivation. Combined with a near-infrared, fluorescence and luminescence measurement systems, it is possible to register cell growth kinetics, pH and O2 non-invasively in real time. For pH and O2, innovative single-use sensor spots are used inside the tubes.

Although O2 supply is one of the major issues in the cultivation of aerobic organisms, especially in oxygen limited conditions, adequate methods for real monitoring of dissolved oxygen were missing, and sufficient O2 supply was usually assumed. Innovative non-invasive oxygen sensors integrated in falcon tubes now enable online oxygen monitoring and give new insights into metabolic activities. The pH is one of the major issues in the cultivation of cells, yeast or bacteria. Cultivation vessels which are sensor limited are widely applied in academic and industrial bioprocess development. As adequate methods for real monitoring of pH were not available, cumbersome at-line sampling was used lacking high data density and interfering with growth. Non-invasive real time pH measurement provides new insights into metabolic activity and changes in metabolic pathways.

FEATURES

  • Parallel cultivation of 8 tube bioreactors enables to save time and resources for bioprocess optimization
  • Individually controlled bioreactor accelerates optimization process
  • Possibility to cultivate microaerophilic and obligate anaerobic microorganisms (not strict anaerobic conditions)
  • Reverse–Spin® mixing principle enables non-invasive biomass measurement in real time
  • Near-infrared optical system makes it possible to register cell growth kinetics
  • Free of charge software for storage, demonstration and analysis of data in real time
  • Compact design with low profile and small footprint for personal application
  • Individual temperature control for bioprocess applications
  • Active cooling for rapid temperature control, e.g. for temperature fluctuation experiments
  • Task profiling for process automatization
  • Cloud data storage to remotely monitor the process of cultivation while at home or using a mobile phone
  • Non-invasive O2 and pH measurement allows for accurate monitoring of metabolic activities

ADVANTAGES OF THE SENSOR SPOTS:

  • They are small
  • Their signal does not depend on the flow rate of the sample
  • They can be physically divided from the measuring system which allows a non-invasive measurement
  • They can be used in disposables
  • Therefore, they are ideally suited for the examination of small sample volumes, for highly parallelized measurements in disposables, and for biotechnological applications

SOFTWARE FEATURES

  • Real–Time cell growth logging
  • Real-Time pH and O2 measurement and logging
  • 3D graphical representation of OD or growth rate over time over unit
  • Pause option
  • Save/Load option
  • Report option: PDF and Excel
  • Remote monitoring option (requires internet connection)
  • Cycling/Profiling options
  • User manual calibration possibility for most cells

TYPICAL APPLICATIONS

  • Fermentation real time growth kinetics
  • Clone candidate screening
  • Protein expression
  • Temperature stress and fluctuation experiments
  • Media screening and optimization
  • Growth characterization
  • Inhibition and toxicity tests
  • Strain quality control
  • Initial bioprocess optimization studies
To fully use RTS-8 plus capabilities, the device must be connected to a PC and RTS-8 plus software. The device cannot be used as a standalone unit.
Light source Laser
Measurement wavelength (λ) 850 ± 15 nm
Measurement range 0-100 OD600
E.coli factory calibration measurement range 0-50 OD600
S.cerevisiae factory calibration measurement range 0-75 OD600
Achievable user calibration measurement error (range 0.1-6 OD600) ± 0.3
Achievable user calibration measurement error (range 6-50 OD600) ≤ 5%
Achievable user calibration measurement error (range 50-75 OD600) ≤ 10%
Measurement periodicity per hour 1-60
Temperature setting range +4°C ... +60°C
Temperature control range +15 °C below ambient ... +60 °C
Temperature stability ±0.3 °C
Sample temperature accuracy (20°C – 37°C) ±1 °C
Tube sockets 8
Sample working volume range 3–50 ml
Speed control range 150–2700 rpm
Reverse spin time setting range 150-250 rpm 0 s
Reverse spin time setting range 250–300 rpm 2-60 s
Reverse spin time setting range 300–2700 rpm 0-60 s
Display LCD
Minimum PC requirements Intel/AMD Processor, 1 GB RAM, Windows Vista/7/8/8.1/10/11, USB 2.0 port
Overall dimensions (W×D×H) 350 x 690 x 300 mm
Weight 20 kg
Nominal operating voltage AC 230 V, 50 Hz
Power consumption 3.15 A / 500 W
--- ---
02 sensor +
Range 0-100%
Accuracy ±0.05% O2 at 0.2%,
±0.4% O2 at 20.9%
Drift <0.03% O2 within 30 days
Temperature range up to 40°C
Response time (t90) <6 s
Storage stability 18 months
--- ---
pH sensor +
Range 4.0 - 8.5 pH
Accuracy ±0.10 pH at pH 7
Drift <0.005 pH per day
Temperature range up to 40°C
Response time (t90) <120 s
Storage stability 18 months

Accessories

50 ml tubes with membrane filter TPP TubeSpin® Bioreactor 50, 20 pcs.

50 ml tubes with membrane filter TPP TubeSpin® Bioreactor 50, 180 pcs.

Sterile TPP TubeSpin® Bioreactor vessel, 50 ml, with pH and O2 sensor spots, 1 pce.

Documentation

SKUProductTypeLanguageFile
RTS-8 PlusRTS-8 PlusDeclaration of ConformityEnglishDownload
RTS-8 PlusRTS-8 PlusBrochureEnglishDownload
RTS-8 PlusRTS-8 PlusWhite PaperEnglishDownload
RTS-8 PlusRTS-8 PlusUser InstructionsEnglishDownload

General Documents

TypeNameLanguageFile
CatalogueEnglishDownload
Weight 20 kg
Dimensions 350 × 690 × 300 mm
Product class

Smart Plus

Model

Calibration E.coli, Calibration E.coli and S.Cerevisiae – optional, Calibration S.Cerevisiae – optional

Related Products

Densitometer is designed for measurement of cell suspension's turbidity in the range of 0.0–6.0 McFarland units (0 – 180×107 cells/ml).

Microplate Photometer HiPo MPP-96 is a compact tabletop device for measuring the results of ELISA and microbiological studies in 96-well microplates. Photometer is controlled and outputs data via computer. The device is supplied with specialized software QuantAssay.

This product has multiple variants. The options may be chosen on the product page

RTS-1C is personal bioreactor which utilize patented Reverse-Spin® technology that applies non-invasive, mechanically driven, low energy consumption, innovative type of agitation where cell suspension is mixed by the singleuse falcon bioreactor tube rotation around its axis with a change of direction of rotation motion resulting in highly efficient mixing and oxygenation for aerobic cultivation. Combined with a near-infrared optical system it is possible to register cell growth kinetics non-invasively in real time.

OD Plate is the measurement verification instrument for microplate photometer MPP-96 HiPo.

DEN-600 is a compact, portable, rechargeable battery powered photometer. DEN-600 comprises of 600 nm wavelength optical system, which enables to apply - 1) OD600 method that estimated total number of cells, 2) McFarland (McF) turbidity measurement method, 3) Bradford protein assay method for protein concentration measurement, 4) other methods that can be adjusted or optimized using 600 nm wavelength.

RTS-8 is a personal bioreactor that utilizes patented Reverse-Spin® technology that applies non-invasive, mechanically driven, low energy consumption, innovative type of agitation where cell suspension is mixed by the single-use falcon bioreactor tube rotation around its axis with a change of direction of rotation motion resulting in highly efficient mixing and oxygenation for aerobic cultivation. Combined with a near-infrared optical system it is possible to register cell growth kinetics non-invasively in real time.

This product has multiple variants. The options may be chosen on the product page

RTS-1 is personal bioreactor which utilize patented Reverse-Spin® technology that applies non-invasive, mechanically driven, low energy consumption, innovative type of agitation where cell suspension is mixed by the singleuse falcon bioreactor tube rotation around its axis with a change of direction of rotation motion resulting in highly efficient mixing and oxygenation for aerobic cultivation. Combined with a near-infrared optical system it is possible to register cell growth kinetics non-invasively in real time.

Densitometer is designed for measurement of cell suspension's turbidity in the range of 0.0–6.0 McFarland units (0 – 180 × 107 cells/ml).

Recently Viewed

Basic Parafuchsin, Basic Red 9, Magenta™ O, Parafuchsin hydrochloride, Paramagenta hydrochloride, Pararosaniline chloride, Pararosaniline hydrochloride

Reagents

O-ANISIDINE LR

2-Aminoanisole, 2-Methoxyaniline

Cold chain transportation for samples, reagents, blood products, specimens and drugs.

This product has multiple variants. The options may be chosen on the product page

Centrifuge Adapters

Adapter set BN-16/100

For rotors R-12/10, Ri-12/10 optional adapter set (12 pcs) - BN-16/100 for vacutainers 8-10 ml [16x100].

  • Nonsterile tips for use with MLA pipettors
  • Contains 5 racks of 192 tips each

Termaks forced convention drying and heating chambers for fast drying and sterilization. Designed for excellent temperature distribution with variable fan settings temperature the entire range offers very high temperature stability up to +250°C.

This product has multiple variants. The options may be chosen on the product page

Products Best Selling

For the separation and purification of samples of cells, macromolecular proteins, blood, body fluids, DNA/RNA, plasmids, bacteria and viruses.

Sterile TPP TubeSpin® Bioreactor vessel, 50 ml, with pH and O2 sensor spots, 1 pce.

20 × 0.2 ml microtubes + 12 × 1.5 ml microtubes

The ES-20 is a compact bench–top Shaker–Incubator used for mixing of biological liquids as well as for incubation and cultivation of biological liquids according to the operator set program

Applicable for storing wholeblood, medicines, biological products and other laboratory products that need to be stored at 4℃. Suitable for the storage of blood and blood articles in areas that have power shortages.

LN2 backup cooling system is an independent refrigeration system for a ULT freezer. When there is a loss of power or the temperature of the freezer rises to the high alarm set point, the LN2 backup system can be automatically activated to inject LN2 into the chamber to maintain the freezer temperature. The backup system operates on a rechargeable battery when there is a loss of main power.

A-12, adapter for work with tubes which are 12 mm in external diameter.

Products Favourite

20 × 0.2 ml microtubes + 12 × 1.5 ml microtubes

Sterile TPP TubeSpin® Bioreactor vessel, 50 ml, with pH and O2 sensor spots, 1 pce.

Applicable for blood stations, hospitals, CDC's, scientific research institutes, chemical industry and other related industries. The -30°C Biomedical Freezer can cryopreserve plasma, biological products, components, materials, and other items that need to be kept at low temperature.

This product has multiple variants. The options may be chosen on the product page

LN2 backup cooling system is an independent refrigeration system for a ULT freezer. When there is a loss of power or the temperature of the freezer rises to the high alarm set point, the LN2 backup system can be automatically activated to inject LN2 into the chamber to maintain the freezer temperature. The backup system operates on a rechargeable battery when there is a loss of main power.

A-12, adapter for work with tubes which are 12 mm in external diameter.

The ES-20 is a compact bench–top Shaker–Incubator used for mixing of biological liquids as well as for incubation and cultivation of biological liquids according to the operator set program

For the separation and purification of samples of cells, macromolecular proteins, blood, body fluids, DNA/RNA, plasmids, bacteria and viruses.

Personal multi-channel bioreactor RTS-8 Plus

SKU: BS-010170 Category: Brand:

RTS-8 plus is a personal bioreactor that utilizes patented Reverse-Spin® technology that applies non-invasive, mechanically driven, low energy consumption, innovative type of agitation where cell suspension is mixed by the single-use falcon bioreactor tube rotation around its axis with a change of direction of rotation motion resulting in highly efficient mixing and oxygenation for aerobic cultivation. Combined with a near-infrared, fluorescence and luminescence measurement systems, it is possible to register cell growth kinetics, pH and O2 non-invasively in real time. For pH and O2, innovative single-use sensor spots are used inside the tubes.

Biosan

Personal multi-channel bioreactor RTS-8 Plus
Personal multi-channel bioreactor RTS-8 Plus
Select options