Plate Thermo–Shakers are designed for shaking and thermostating 4 standard 96–well microplates.

A multisystem principle, used in design of the Thermo–Shaker, allows operating it as 3 independent devices:

  • Incubator;
  • Microplate shaker;
  • Thermo–Shaker.

A distinctive feature of Biosan Plate Thermo–Shakers is the patented by the company Two–Side Microplates Heating, which allows to achieve full correspondence of the set and actual temperature in the microplate wells.

Thermo-shaker provides heating up to 60°C, which is sufficient for carrying out ELISA tests.

Plate Shaker–Thermostat provides:

  • Soft or intensive sample shaking
  • Rotation speed regulation, stabilization and indication
  • Even rotation amplitude throughout the Thermo-Shaker platform
  • Required operation time setting and indication
  • Automatic stopping of the platform movement after expiration of the set time
  • Setting and indication of the required temperature on the platform
  • Automatic fault diagnostics (temperature sensor, platform heating, lid heating etc.)
  • Spring clamps

Application fields:

  • Сytochemistry — for in situ reactions
  • Immunochemistry — for immunofermentative reactions
  • Biochemistry — for enzyme and protein analysis
  • Molecular biology — for micro array analysis

Temperature Calibration Function

With the help of the temperature calibration function the user can calibrate the unit approx. ±6% of the selected temperature to compensate differences in the thermal behaviour of plates from different manufacturers.

Temperature setting range +25°C ... +60°C
Temperature control range +5°C above ambient... +60°C
Temperature setting resolution 0.1°C
Temperature stability ±0.1°C
Temperature uniformity at +37°C ±0.25°C
Temperature calibration coefficient range 0.936...1.063 (± 0.063)
Heating Patented two–side microplate heating
Speed control range 250–1200 rpm (increment 10 rpm)
Digital time setting 1 min–96 hrs / non–stop (increment 1 min)
Timer sound signal +
Orbit 2 mm
Display LCD, 16 x 2 signs
Maximum continuous operation time 168 h
Max. height of microtest plate 18 mm
Number of microtest plates 4
Platform dimensions (w x d) 290 x 210 mm
Overall dimensions (W×D×H) 380 x 390 x 140 mm
Weight 8.8 kg
Input current/power consumption 12 V DC, 4.15 A / 50 W
External power supply Input AC 100–240 V; 50/60 Hz; Output DC 12 V

Documentation

SKUProductTypeLanguageFile
PST-60HL-4PST-60HL-4BrochureEnglishDownload
PST-60HL-4PST-60HL-4BrochureEnglishDownload
PST-60HL-4PST-60HL-4BrochureEnglishDownload
Weight 8,8 kg
Dimensions 380 × 390 × 140 mm
Product class

Premium

Related Products

Plate Thermo–Shakers are designed for shaking and thermostating 2 standard 96–well microplates.

The Assist series pipettes are single or 8, 12 channel variable volume pipettes designed to measure and transfer volumes from 0.1 μl to 10000 μl depending on the model.

This product has multiple variants. The options may be chosen on the product page

Thermo–Shaker TS-100C provides intensive mixing and temperature control of samples in microtest tubes or PCR plate. This model of Thermo–Shaker differs from TS-100 with a possibility of cooling samples down to +4°C.

TS-DW Thermo–Shaker is designed for shaking and incubating deep well plates. A multisystem principle, used in the design of the Thermo-Shaker, allows operating it as 3 independent devices: Incubator, Plate shaker and Thermo–Shaker.

Thermo–Shaker TS-100C Smart provides intensive mixing and temperature control of samples in microtest tubes or PCR plate. This model of Thermo–Shaker differs from TS-100 with a possibility of cooling samples down to +4°C and with control up to 7 units from PC via Bluetooth® technology.

Plate Thermo–Shakers are designed for shaking and thermostating 2 standard 96–well microplates.

Microplate Photometer HiPo MPP-96 is a compact tabletop device for measuring the results of ELISA and microbiological studies in 96-well microplates. Photometer is controlled and outputs data via computer. The device is supplied with specialized software QuantAssay.

This product has multiple variants. The options may be chosen on the product page

Inteliwasher 3D-IW8 series microplate washer is designed for washing various types of standard 96-well microtitre plates, microstrips as well as microarrays on FastFRAME (rectangular well shape). It is suitable for washing wells with different bottom shapes: flat, U-shape and V-shape. The unit is fully programmable ensuring multi-step solution ripening, aspiration (aspiration, combination of  aspiration/liquid dispensing and soaking, as well as soaking cycle during a particular period of time). Dispense system of liquid dosage for each channel separately.

OD Plate is the measurement verification instrument for microplate photometer MPP-96 HiPo.

Mini–Shaker PSU-2T is designed for immunoassays and provides adjustable mixing of reagents in microplates. The device ensures smooth movement of the platform even at low speeds. Shaker is a compact and user-friendly device. It takes up little space on a desk and is ideal for personal use.

The Assist series pipettes with volume lock are single or 8, 12 channel variable volume pipettes designed to measure and transfer volumes from 0.1 μl to 10000 μl depending on the model.

This product has multiple variants. The options may be chosen on the product page

Aspirator with trap flask FTA-2i is designed for aspiration or removal of alcohol, buffer and liquid from reaction vessels (e.g. during DNA/RNA purification or other macromolecule reprecipitation techniques).

Recently Viewed

The Walnut Protein ELISA Kit is a microwell sandwich ELISA, used for the quantitative analysis of low levels of walnut residues in food products, ingredients, clean in place (CIP) rinses and environmental swabs in a 96 well format. The quantity of protein in the sample can be extrapolated from the standard curve, constructed from standards of know concentration, and adjusted to consider the sample dilution.

2-Hydroxy-1,2,3-propanetricarboxylic acid anhydrous

Stirrer Accessories

Support rod and base SRB

Support rod and base for device mounting.

Rotors

Rotor SR-16

Rotor for 2 x 8-section 0,2 ml microtube strips.

Products Best Selling

For the separation and purification of samples of cells, macromolecular proteins, blood, body fluids, DNA/RNA, plasmids, bacteria and viruses.

Sterile TPP TubeSpin® Bioreactor vessel, 50 ml, with pH and O2 sensor spots, 1 pce.

20 × 0.2 ml microtubes + 12 × 1.5 ml microtubes

Applicable for storing wholeblood, medicines, biological products and other laboratory products that need to be stored at 4℃. Suitable for the storage of blood and blood articles in areas that have power shortages.

The ES-20 is a compact bench–top Shaker–Incubator used for mixing of biological liquids as well as for incubation and cultivation of biological liquids according to the operator set program

LN2 backup cooling system is an independent refrigeration system for a ULT freezer. When there is a loss of power or the temperature of the freezer rises to the high alarm set point, the LN2 backup system can be automatically activated to inject LN2 into the chamber to maintain the freezer temperature. The backup system operates on a rechargeable battery when there is a loss of main power.

A-12, adapter for work with tubes which are 12 mm in external diameter.

Products Favourite

For the separation and purification of samples of cells, macromolecular proteins, blood, body fluids, DNA/RNA, plasmids, bacteria and viruses.

20 × 0.2 ml microtubes + 12 × 1.5 ml microtubes

Sterile TPP TubeSpin® Bioreactor vessel, 50 ml, with pH and O2 sensor spots, 1 pce.

Applicable for blood stations, hospitals, CDC's, scientific research institutes, chemical industry and other related industries. The -30°C Biomedical Freezer can cryopreserve plasma, biological products, components, materials, and other items that need to be kept at low temperature.

This product has multiple variants. The options may be chosen on the product page

LN2 backup cooling system is an independent refrigeration system for a ULT freezer. When there is a loss of power or the temperature of the freezer rises to the high alarm set point, the LN2 backup system can be automatically activated to inject LN2 into the chamber to maintain the freezer temperature. The backup system operates on a rechargeable battery when there is a loss of main power.

A-12, adapter for work with tubes which are 12 mm in external diameter.

The ES-20 is a compact bench–top Shaker–Incubator used for mixing of biological liquids as well as for incubation and cultivation of biological liquids according to the operator set program

Plate Shaker-Thermostat PST-60HL-4

SKU: BS-010128-AAI Categories: , Brand:

Plate Thermo–Shakers are designed for shaking and thermostating 4 standard 96–well microplates.

Biosan

Plate Shaker-Thermostat PST-60HL-4
Plate Shaker-Thermostat PST-60HL-4