Key Features:

  • Useful height of 1000 mm
  • Depth of 900 mm
  • Fully openable front
  • Can be configured as 3-filter, B2 or laminar flow

The n-Safe XL cabinets are manufactured according to EN 12469 and can also be delivered as a three-filter cabinet with H14 prefilters according to DIN12980, B2 cabinets with 100% exhaust air or as an Open Laminar Flow cabinet for product protection.

Technical specifications

Category Property Unit 1200 1500 1800
Size External dimensions excl support, WxDxH mm 1303×1176×1652 1603×1176×1652 1907×1176×1652
External dimensions incl support, table top at 800 mm, WxDxH mm 1303×1176×2380 1603×1176×2380 1907×1176×2380
Internal dimensions, WxDxH mm 1200×855(970)×1000 1500×855(970)×1000 1800×855(970)×1000
Front window opening mm 200 (adjustable 160–330)
Work height, adjustable support stand mm 700–1050
Work height, electrically elevated support stand mm 750–1050
Minimum door way mm 1180, but can be finally assembled on site
Weight Equipment kg 310 350 390
Air Velocity Vertical Flow m/s 0.28 (adjustable 0.25–0.53)
Inflow m/s 0.45 (adjustable 0.45–0.55)
Deviation ±% <8
Noise Noise level (EN12469) dB(A) 56 57 57
Ventilation Down flow rate m³/h 960 1200 1440
Exhaust flow rate m³/h 390 480 580
Filter Technology Main/Exhaust type HEPA H14 EN1822, 99.999% at 0.3 μm
Light LED lux 0–2000, dimmable
Electrical Data Voltage frequency V/Hz 220–240/50–60 or 110–120/50–60
Power consumption, from W 140 180 190

Dimensions

Cabinet A - Length B - Work height C - Top cabinet D - Highest point E - Work opening W - Weight
n-SAFE 1200 XL 1303 mm 700–1050 mm 2280–2630 mm 2300–2650 mm 1200 mm 310 kilo
n-SAFE 1500 XL 1603 mm 700–1050 mm 2280–2630 mm 2300–2650 mm 1500 mm 350 kilo
n-SAFE 1800 XL 1907 mm 700–1050 mm 2280–2630 mm 2300–2650 mm 1800 mm 390 kilo

Documentation

SKUProductTypeLanguageFile
BrochureEnglishDownload
Dimensions

1200, 1500, 1800

Related Products

Economical variant of the n-SAFE Class II Pro, it maintains essential security but with reduced options. Good for labs on a budget.

This product has multiple variants. The options may be chosen on the product page

A highly reliable Class III cabinet, designed and manufactured according to EN 12469. Ermetic glove box for work with highly dangerous agents. Full containment, with dual HEPA filters, leak-tight valves and optional shielding.

The n-Safe Class I for operator protection against low/moderate risk agents. No recirculation. Simple, robust and silent, according to EN 12469.  

This product has multiple variants. The options may be chosen on the product page

Specialized for handling cytotoxic drugs. Features triple HEPA H14 filtration, low noise, and enhanced ergonomics. Complies with EN 12469 and DIN 12980, ideal for hazardous compounds.    

This product has multiple variants. The options may be chosen on the product page

The n-Safe Pro cabinets are designed, to provide superior operator and product protection according to EN-12469 and NSF/ANSI 49 The most versatile and popular model in the range, offering high performance, ergonomic design, quiet operation, and touchscreen. Ideal for routine and research labs.  

This product has multiple variants. The options may be chosen on the product page

The n-Safe B2 cabinets are microbiological safety cabinets according to EN 12469. It protects the product as well as the operator and has 100% exhaust which means no recirculating air, making it ideal for volatile chemicals.  

This product has multiple variants. The options may be chosen on the product page

Larger version of the nSafe Sterile model. Suitable for sterile work with bulky equipment and manufactured according to EN 12469. Custom Order only.

The n-Safe Sterile is an Open Laminar Flow Cabinet, which provides a controlled environment whit vertical laminar flow. The products, which are handled inside the n-Safe Sterile are protected from any kind of contamination which makes it ideal for sterile environments.

This product has multiple variants. The options may be chosen on the product page

Recently Viewed

Nickel(II) chloride hexahydrate

Reagents

SUCROSE AR

a-D-Glucopyranosyl ß-D-fructofuranoside; ß-D-Fructofuranosyl-a-D-glucopyranosid;, D(+)-Saccharose; Sugar

Nitric acid silver(I) salt

Platform with clamps for flasks.

Grant SBB series boiling baths are reliable, high quality unstirred boiling baths for direct immersion of samples. They provide continuous, steady 100°C operation without violent boiling, spitting or producing excessive steam.

This product has multiple variants. The options may be chosen on the product page

Biosafety Air - UV - Cleaner Boxes

DNA/RNA UV-cleaner box UVT-B-AR

DNA/RNA UV-cleaner box UVT-B-AR is designed for clean operations with DNA samples. UV-Cabinet provide protection against contamination.

Products Best Selling

For the separation and purification of samples of cells, macromolecular proteins, blood, body fluids, DNA/RNA, plasmids, bacteria and viruses.

Applicable for storing wholeblood, medicines, biological products and other laboratory products that need to be stored at 4℃. Suitable for the storage of blood and blood articles in areas that have power shortages.

A-12, adapter for work with tubes which are 12 mm in external diameter.

The ES-20 is a compact bench–top Shaker–Incubator used for mixing of biological liquids as well as for incubation and cultivation of biological liquids according to the operator set program

LN2 backup cooling system is an independent refrigeration system for a ULT freezer. When there is a loss of power or the temperature of the freezer rises to the high alarm set point, the LN2 backup system can be automatically activated to inject LN2 into the chamber to maintain the freezer temperature. The backup system operates on a rechargeable battery when there is a loss of main power.

Sterile TPP TubeSpin® Bioreactor vessel, 50 ml, with pH and O2 sensor spots, 1 pce.

20 × 0.2 ml microtubes + 12 × 1.5 ml microtubes

Products Favourite

LN2 backup cooling system is an independent refrigeration system for a ULT freezer. When there is a loss of power or the temperature of the freezer rises to the high alarm set point, the LN2 backup system can be automatically activated to inject LN2 into the chamber to maintain the freezer temperature. The backup system operates on a rechargeable battery when there is a loss of main power.

A-12, adapter for work with tubes which are 12 mm in external diameter.

The ES-20 is a compact bench–top Shaker–Incubator used for mixing of biological liquids as well as for incubation and cultivation of biological liquids according to the operator set program

For the separation and purification of samples of cells, macromolecular proteins, blood, body fluids, DNA/RNA, plasmids, bacteria and viruses.

20 × 0.2 ml microtubes + 12 × 1.5 ml microtubes

Sterile TPP TubeSpin® Bioreactor vessel, 50 ml, with pH and O2 sensor spots, 1 pce.

Applicable for blood stations, hospitals, CDC's, scientific research institutes, chemical industry and other related industries. The -30°C Biomedical Freezer can cryopreserve plasma, biological products, components, materials, and other items that need to be kept at low temperature.

This product has multiple variants. The options may be chosen on the product page

nSAFE Class II XL

SKU: N/A Category: Brand:

The n-Safe XL cabinets offer extraordinary inner dimensions, whenever the working space of a standard cabinet isn ́t sufficient: XL cabinets come with an interior height of 1000mm and an interior depth of 900 mm. The complete front can be opened to easily fit in large devices, e.g. a pipetting robot.

Nordic Labtech

nSAFE Class II XL
nSAFE Class II XL
Select options