Densitometer is designed for measurement of cell suspension’s turbidity in the range of 0.0–6.0 McFarland units (0 – 180×107 cells/ml).

Densitometers provide the opportunity to measure solution turbidity in a wider range (up to 15.0 McFarland units) however, it is necessary to remember that in this case the standard deviation values increase.

A densitometer is used for measurement of cell concentration (bacterial, yeast cells) during fermentation process, determination of microorganism sensitivity to antibiotics, microorganism identification using various test-systems, for measurement of absorption at the definite wavelength, as well as for quantitative estimation of concentration of colour solution, absorbing green light.

The operation principle is based on measurement of optical density with digital presentation of  results in McFarland units. The unit is calibrated at the factory (for operation with 16 mm diameter glass tubes) and keeps calibration without power supply. However, if necessary it is possible to calibrate the unit by 2–6 points in 0.0–6.0 McFarland unit range. We recommend to use Biosan standards to ensure full reliability, but it is acceptable to use other commercial as well as self prepared standards (e.g. BaSO4). Possibility to restore factory calibration settings.

Following calibration kits are available on request:

  • CKG16 for glass tubes with diameter 16 mm, set of 0.5; 1.0; 2.0; 3.0; 4.0 McFarland Turbidity Standards (latex particles).
    Cat.Nr.: BS-050102-BK
  • Calibration kit for glass tubes with diameter 18 mm, set of 0.5; 1.0; 2.0; 3.0; 4.0; 5.0 McFarland Turbidity Standards (BaSO4).
    Cat.Nr.: 70900
  • Calibration kit for glass tubes with diameter 12 mm, set of 0.0 (blank); 0.5; 2.0; 3.0 McFarland Turbidity Standards (latex particles).
    Cat.Nr.: 21255

Two versions of the product are available:

  1. DEN-1 powered from external energy supply;
  2. DEN-1B powered both from external energy supply and from batteries (АА).
Measurement range 0.00–15.00 McF
Display resolution 0.01 McF
Light source LED
Measurement wavelength (λ) λ = 565 ±15 nm
Accuracy (0.0–6.0 McF) ±3%
Measurement time 1 s
Sample volume not less than 2 ml
Tube external diameter 12 mm, 16 mm (using A-12, A-16 adapter) or 18 mm (without adapter)
Possibility to restore factory calibration settings +
Display LCD
Independent power supply 3 × AA batteries
Overall dimensions (W×D×H) 165 × 115 × 75 mm
Weight 0.7 kg
Input current/power consumption 12 V, 7 mA / 0.1 W
External power supply Input AC 100–240 V, 50/60 Hz; Output DC 12 V
Standard set External power supply, A-16

Accessories

Glass Test Tubes 16x100mm, high borosilicate, PP Cap with silicone pad. Packing - 100 pcs/box

CKG16 for glass tubes with diameter 16 mm, set of 0.5; 1.0; 2.0; 3.0; 4.0 McFarland Turbidity Standards (latex particles).

McFarland Turbidity Standards, Ø18mm.

McFarland Turbidity Standards, Ø12mm.

Glass Test Tubes 18x100mm, high borosilicate, PP Cap with silicone pad. Packing - 100 pcs/box

A-12, adapter for work with tubes which are 12 mm in external diameter.

Documentation

SKUProductTypeLanguageFile
DEN-1BDEN-1BBrochureEnglishDownload
DEN-1BDEN-1BUser InstructionsEnglishDownload
DEN-1BDEN-1BDeclaration of ConformityEnglishDownload

General Documents

TypeNameLanguageFile
CatalogueEnglishDownload
Weight 0,7 kg
Dimensions 165 × 115 × 75 mm
Product class

Premium

Related Products

RTS-1C is personal bioreactor which utilize patented Reverse-Spin® technology that applies non-invasive, mechanically driven, low energy consumption, innovative type of agitation where cell suspension is mixed by the singleuse falcon bioreactor tube rotation around its axis with a change of direction of rotation motion resulting in highly efficient mixing and oxygenation for aerobic cultivation. Combined with a near-infrared optical system it is possible to register cell growth kinetics non-invasively in real time.

RTS-1 is personal bioreactor which utilize patented Reverse-Spin® technology that applies non-invasive, mechanically driven, low energy consumption, innovative type of agitation where cell suspension is mixed by the singleuse falcon bioreactor tube rotation around its axis with a change of direction of rotation motion resulting in highly efficient mixing and oxygenation for aerobic cultivation. Combined with a near-infrared optical system it is possible to register cell growth kinetics non-invasively in real time.

Densitometer is designed for measurement of cell suspension's turbidity in the range of 0.0–6.0 McFarland units (0 – 180 × 107 cells/ml).

Microplate Photometer HiPo MPP-96 is a compact tabletop device for measuring the results of ELISA and microbiological studies in 96-well microplates. Photometer is controlled and outputs data via computer. The device is supplied with specialized software QuantAssay.

This product has multiple variants. The options may be chosen on the product page

DEN-600 is a compact, portable, rechargeable battery powered photometer. DEN-600 comprises of 600 nm wavelength optical system, which enables to apply - 1) OD600 method that estimated total number of cells, 2) McFarland (McF) turbidity measurement method, 3) Bradford protein assay method for protein concentration measurement, 4) other methods that can be adjusted or optimized using 600 nm wavelength.

OD Plate is the measurement verification instrument for microplate photometer MPP-96 HiPo.

RTS-8 is a personal bioreactor that utilizes patented Reverse-Spin® technology that applies non-invasive, mechanically driven, low energy consumption, innovative type of agitation where cell suspension is mixed by the single-use falcon bioreactor tube rotation around its axis with a change of direction of rotation motion resulting in highly efficient mixing and oxygenation for aerobic cultivation. Combined with a near-infrared optical system it is possible to register cell growth kinetics non-invasively in real time.

This product has multiple variants. The options may be chosen on the product page

RTS-8 plus is a personal bioreactor that utilizes patented Reverse-Spin® technology that applies non-invasive, mechanically driven, low energy consumption, innovative type of agitation where cell suspension is mixed by the single-use falcon bioreactor tube rotation around its axis with a change of direction of rotation motion resulting in highly efficient mixing and oxygenation for aerobic cultivation. Combined with a near-infrared, fluorescence and luminescence measurement systems, it is possible to register cell growth kinetics, pH and O2 non-invasively in real time. For pH and O2, innovative single-use sensor spots are used inside the tubes.

This product has multiple variants. The options may be chosen on the product page

Recently Viewed

Propenoic Acid Ethylenecarboxylic Acid

Tips Consumables

Low Retention Tips

Coated inner wall delivers super hydrophobicity and can effectively reduce the occurrence of wall hanging; Ultra-fine grinding molding technology, demolding without any agent guarantees better product quality; Suitable for important procedures requiring high micro-pipetting accuracy; Without any need for pre-wetting the tip during the testing, low retention tips can reduce the loss of precious samples and improve their recovery rate; Suitable for the pipetting of samples containing molecules that can easily be adsorbed on the surface of the tip, such as DNA, proteins, peptides, etc; RNase, DNase, human DNA and Pyrogen Free.

This product has multiple variants. The options may be chosen on the product page

Laboratory Refrigerator

Laboratory Refrigerator

Typical Installation Used to store chemicals, reagents and consumables within laboratories and research facilities.  

3,8-Diamino-5-ethyl-6-phenylphenanthridinium bromide, EtBr, Homidium bromide

Products Best Selling

Sterile TPP TubeSpin® Bioreactor vessel, 50 ml, with pH and O2 sensor spots, 1 pce.

For the separation and purification of samples of cells, macromolecular proteins, blood, body fluids, DNA/RNA, plasmids, bacteria and viruses.

20 × 0.2 ml microtubes + 12 × 1.5 ml microtubes

The ES-20 is a compact bench–top Shaker–Incubator used for mixing of biological liquids as well as for incubation and cultivation of biological liquids according to the operator set program

New modular design of laboratory furniture provides flexibility and ease of use.

Contamination is especially problematic in the highly sensitive PCR technique. Originating from aerosolized fragments, contaminant DNA can lead to cross contamination thus resulting in inaccurate data and as a result misinterpreted analysis.

DNA/RNA UV-cleaner box UVC/T-M-AR is designed for clean operations with DNA samples. UV-cleaner box provide protection against contamination.

DNA/RNA UV-cleaner box UVT-B-AR is designed for clean operations with DNA samples. UV-Cabinet provide protection against contamination.

LN2 backup cooling system is an independent refrigeration system for a ULT freezer. When there is a loss of power or the temperature of the freezer rises to the high alarm set point, the LN2 backup system can be automatically activated to inject LN2 into the chamber to maintain the freezer temperature. The backup system operates on a rechargeable battery when there is a loss of main power.

Products Favourite

The new CAPPSolo single channel pipettes are built to meet the liquid-transfer needs of the modern laboratory. These dependable work-horses are the ideal micropipette for research, clinical and academic laboratories that require great quality without breaking the bank. Here are some brief highlights of what you can expect from these excellent mechanical pipettes.

This product has multiple variants. The options may be chosen on the product page

Applicable for blood stations, hospitals, CDC's, scientific research institutes, chemical industry and other related industries. The -30°C Biomedical Freezer can cryopreserve plasma, biological products, components, materials, and other items that need to be kept at low temperature.

This product has multiple variants. The options may be chosen on the product page

LN2 backup cooling system is an independent refrigeration system for a ULT freezer. When there is a loss of power or the temperature of the freezer rises to the high alarm set point, the LN2 backup system can be automatically activated to inject LN2 into the chamber to maintain the freezer temperature. The backup system operates on a rechargeable battery when there is a loss of main power.

A-12, adapter for work with tubes which are 12 mm in external diameter.

The ES-20 is a compact bench–top Shaker–Incubator used for mixing of biological liquids as well as for incubation and cultivation of biological liquids according to the operator set program

For the separation and purification of samples of cells, macromolecular proteins, blood, body fluids, DNA/RNA, plasmids, bacteria and viruses.

20 × 0.2 ml microtubes + 12 × 1.5 ml microtubes

Sterile TPP TubeSpin® Bioreactor vessel, 50 ml, with pH and O2 sensor spots, 1 pce.

This product is used in micro centrifugal scenarios (single tube capacity is less than or equal to 2ml)

This product has multiple variants. The options may be chosen on the product page

Cover of a unique sealed structure design provides a two-way guarantee and ensures the sealing property Conical thickened design at the bottom to increase the maximum centrifugal limit Max. centrifugal force: 7000 xg Tolerable temperature range: -80℃-120℃ Clear scale for accurate and convenient data reading Sterile and RNase, DNase, human DNA and Pyrogen Free

This product has multiple variants. The options may be chosen on the product page

The n-Safe Pro cabinets are designed, to provide superior operator and product protection according to EN-12469 and NSF/ANSI 49 The most versatile and popular model in the range, offering high performance, ergonomic design, quiet operation, and touchscreen. Ideal for routine and research labs.  

This product has multiple variants. The options may be chosen on the product page

Densitometer DEN-1B

SKU: BS-050104-AAF Category: Brand:

Densitometer is designed for measurement of cell suspension’s turbidity in the range of 0.0–6.0 McFarland units (0 – 180×107 cells/ml).

Biosan

Densitometer DEN-1B
Densitometer DEN-1B