Inteliwasher 3D-IW8 series microplate washer is designed for washing various types of standard 96-well microtitre plates, microstrips as well as microarrays on FastFRAME (rectangular well shape). It is suitable for washing wells with different bottom shapes: flat, U-shape and V-shape. The unit is fully programmable ensuring multi-step solution ripening, aspiration (aspiration, combination of  aspiration/liquid dispensing and soaking, as well as soaking cycle during a particular period of time). Dispense system of liquid dosage for each channel separately.

The unit provides:

  • Washing mode
  • Rinsing mode
  • Mixing mode
  • Single point, two point, circular (circle or rectangular path) aspiration
  • Possibility of additional solution mixing during time gap between two work cycles
  • Possibility to use microtest plates by different manufacturers, ensured by automated plate set up (adjusting to different depths of plate wells)
  • Round-bottom plate and strip washing mode
  • Possibility of user-defined programs with adjustable parameters

The unit has 50 programs divided into 5 following aspiration categories (see figure rightward):

  • Type 1 (1.0–1.9) IPF96 U/V is intended for round and V-shape immunoplates, 1 point aspiration.
  • Type 2 (2.0–2.9) IPF96 FLAT-2 is intended for flat-bottom shape immunoplates, 2 point aspiration.
  • Type 3 (3.0–3.9) IPF96 FLAT-C is intended for rectangular shape immunoplates, full-circle aspiration direction.
  • Type 4 (4.0–4.9) FastFRAME-2 is intended for multi-slide plate* with rectangular wells.
  • Type 5 (5.0–5.9) FastFRAME-C is intended for multi-slide* plate with rectangular wells.

* – The FastFRAME (GVS Life Sciences) multi-slide plate or analog plate of another manufacturer, that is compatible with standard 25 x 76 mm (1 x 3 inch) glass slides.

The unit is designed for use in closed laboratory rooms at temperatures from +10°С to +35°С and relative humidity up to 80% at +25°С decreasing linearly to 50% relative humidity at 35°C.

4-channel washing solution weight logger, 4 CHW Logger provides automatic control of rinsing solution and waste volumes. The washer shows remaining volume for each bottle as percentage and gives a warning message in case of low solution volume or full waste bottle when 4 CHW Logger is connected.

Specification:

Minimum dispense volume 25 μl
Maximum dispense volume 1600 μl
Dispense increment 25 μl
Dispensing accuracy ±2.5%
Allowed residual liquid volume in plate well not more than 2 μl
Number of wells washed simultaneously 8
Number of washing cycles 1–15
Aspiration time 1–3 s
Aspiration/dispensing speed 3 levels
Max. number of channels in a program 2
Choice of 3 washing liquid bottles +
Soaking time 0–300 s (increment 10 s)
Shaking time 0–150 s (increment 5 s)
Number of washed rows 1 – 12
Time of plate single wash (350 μl), not more 45 s
Number of programs 50
Plate platform and washing head movement automated
Indication of operation modes LCD, 8-line
Overall dimensions (W×D×H) 375 х 345 х 180 mm
Weight 9.9 kg
Input current/power consumption 12 V DC, 1.8 A / 22 W
External power supply Input AC 100–240 V; 50/60 Hz; Output DC 12 V

Specification

Accessories

4-channel washing solution weight logger, 4 CHW Logger provides automatic control of rinsing solution and waste volumes.

Weight 9,9 kg
Dimensions 375 × 345 × 180 mm
Product class

Premium

Related Products

Mini–Shaker PSU-2T is designed for immunoassays and provides adjustable mixing of reagents in microplates. The device ensures smooth movement of the platform even at low speeds. Shaker is a compact and user-friendly device. It takes up little space on a desk and is ideal for personal use.

The Assist series pipettes with volume lock are single or 8, 12 channel variable volume pipettes designed to measure and transfer volumes from 0.1 μl to 10000 μl depending on the model.

This product has multiple variants. The options may be chosen on the product page

Aspirator with trap flask FTA-2i is designed for aspiration or removal of alcohol, buffer and liquid from reaction vessels (e.g. during DNA/RNA purification or other macromolecule reprecipitation techniques).

Plate Thermo–Shakers are designed for shaking and thermostating 4 standard 96–well microplates.

The Assist series pipettes are single or 8, 12 channel variable volume pipettes designed to measure and transfer volumes from 0.1 μl to 10000 μl depending on the model.

This product has multiple variants. The options may be chosen on the product page

Plate Thermo–Shakers are designed for shaking and thermostating 2 standard 96–well microplates.

Intelispeed Washer IW-8 is designed for washing of standard flat-bottom 96 well plates and microstrips. The unit is fully programmable ensuring multi-step solution ripening, aspiration (aspiration, combination of aspiration/liquid dispensing and soaking, as well as soaking cycle during a particular period of time).

Aspirator with trap flask FTA-1 is designed for aspiration/removal of alcohol/buffer remaining quantities from microtest tube walls during DNA/RNA purification and other macromolecule reprecipitation techniques.

OD Plate is the measurement verification instrument for microplate photometer MPP-96 HiPo.

Microplate Photometer HiPo MPP-96 is a compact tabletop device for measuring the results of ELISA and microbiological studies in 96-well microplates. Photometer is controlled and outputs data via computer. The device is supplied with specialized software QuantAssay.

This product has multiple variants. The options may be chosen on the product page

Recently Viewed

Products Best Selling

Sterile TPP TubeSpin® Bioreactor vessel, 50 ml, with pH and O2 sensor spots, 1 pce.

For the separation and purification of samples of cells, macromolecular proteins, blood, body fluids, DNA/RNA, plasmids, bacteria and viruses.

20 × 0.2 ml microtubes + 12 × 1.5 ml microtubes

The ES-20 is a compact bench–top Shaker–Incubator used for mixing of biological liquids as well as for incubation and cultivation of biological liquids according to the operator set program

LN2 backup cooling system is an independent refrigeration system for a ULT freezer. When there is a loss of power or the temperature of the freezer rises to the high alarm set point, the LN2 backup system can be automatically activated to inject LN2 into the chamber to maintain the freezer temperature. The backup system operates on a rechargeable battery when there is a loss of main power.

Applicable for storing wholeblood, medicines, biological products and other laboratory products that need to be stored at 4℃. Suitable for the storage of blood and blood articles in areas that have power shortages.

A-12, adapter for work with tubes which are 12 mm in external diameter.

Products Favourite

20 × 0.2 ml microtubes + 12 × 1.5 ml microtubes

Sterile TPP TubeSpin® Bioreactor vessel, 50 ml, with pH and O2 sensor spots, 1 pce.

Applicable for blood stations, hospitals, CDC's, scientific research institutes, chemical industry and other related industries. The -30°C Biomedical Freezer can cryopreserve plasma, biological products, components, materials, and other items that need to be kept at low temperature.

This product has multiple variants. The options may be chosen on the product page

LN2 backup cooling system is an independent refrigeration system for a ULT freezer. When there is a loss of power or the temperature of the freezer rises to the high alarm set point, the LN2 backup system can be automatically activated to inject LN2 into the chamber to maintain the freezer temperature. The backup system operates on a rechargeable battery when there is a loss of main power.

A-12, adapter for work with tubes which are 12 mm in external diameter.

The ES-20 is a compact bench–top Shaker–Incubator used for mixing of biological liquids as well as for incubation and cultivation of biological liquids according to the operator set program

For the separation and purification of samples of cells, macromolecular proteins, blood, body fluids, DNA/RNA, plasmids, bacteria and viruses.

Inteliwasher 3D-IW8

SKU: BS-060102-AAI Categories: , Brand:

Inteliwasher 3D-IW8 series microplate washer is designed for washing various types of standard 96-well microtitre plates, microstrips as well as microarrays on FastFRAME (rectangular well shape). It is suitable for washing wells with different bottom shapes: flat, U-shape and V-shape. The unit is fully programmable ensuring multi-step solution ripening, aspiration (aspiration, combination of  aspiration/liquid dispensing and soaking, as well as soaking cycle during a particular period of time). Dispense system of liquid dosage for each channel separately.

Biosan

Inteliwasher 3D-IW8
Inteliwasher 3D-IW8