How does UV-Air Flow Cleaner-Recirculator work?
Operation principle is based on a constant, forced air circulation through recirculator`s chamber in close vicinity to UV lamps, thus ensuring maximal efficiency of disinfection. The inner mirror surface of recirculator chamber reflects ultraviolet rays thereby increasing the density of UV radiation and enhancing the disinfection effect.

What does UV Air Flow Cleaner-Recirculator consist of?
UV Air Flow Cleaner-Recirculator consists of a germicidal UV lamp, a fan unit equipped with dust filters and a control unit, confined in a flowthrough chamber.

What are the Benefits of UVR-M recirculators?

  • UV Air Recirculators are ideal for air disinfection in hospitals (especially in outpatient departments, operating rooms, emergency rooms, delivery rooms etc.), kindergartens, research laboratories, veterinary clinics
  • Recirculators are effective against common airborne diseases by disinfecting the air and efficiently destroying disease-causing agents (viruses, microorganisms) by UV radiation
  • Provide complete protection from UV radiation
  • Easy to install, operate and maintain. Very low noise level

Recirculator fixation:

  • Convenient fixation on walls (standard)
  • Mounting on a movable stand (optional)

Specification:

UV radiation source: 1 lamp – 25W, Bactericidal UV-C, TUV 25W 1SL/25
UV radiation level 18 mW / cm2 / sec
Radiation type UV (λ = 253.7 nm), ozone-free
Air-flow productivity 21 m3/hour
Full user protection from direct UV light +
UV lamp operation indicator +
Lamp service life 9000 h
Overall dimensions (W×D×H) 110 x 130 x 660 mm
Weight 2.7 kg
Power consumption (230V / 120 V) 125 W (0.54 A) / 160 W (1.3 A)
Nominal operating voltage 230 V, 50 Hz or 120 V, 60 Hz
Tripod UVR-S dimensions 510 x 510 x ~1100 mm

Specification

Accessories

Weight 2,7 kg
Dimensions 110 × 130 × 660 mm
Product class

Basic Plus

Related Products

DNA/RNA UV-cleaner box UVT-S-AR is designed for clean operations with DNA samples. UV-cleaner box provide protection against contamination.

Operation principle is based on a constant, forced air circulation through recirculator`s chamber in close vicinity to UV lamps, thus ensuring maximal efficiency of disinfection. The inner mirror surface of recirculator chamber reflects ultraviolet rays thereby increasing the density of UV radiation and enhancing the disinfection effect.

Contamination is especially problematic in the highly sensitive PCR technique. Originating from aerosolized fragments, contaminant DNA can lead to cross contamination thus resulting in inaccurate data and as a result misinterpreted analysis.

DNA/RNA UV-cleaner box UVC/T-M-AR is designed for clean operations with DNA samples. UV-cleaner box provide protection against contamination.

Contamination is especially problematic in the highly sensitive PCR technique. Originating from aerosolized fragments, contaminant DNA can lead to cross contamination thus resulting in inaccurate data and as a result misinterpreted analysis.

DNA/RNA UV-cleaner box UVT-B-AR is designed for clean operations with DNA samples. UV-Cabinet provide protection against contamination.

Recently Viewed

4-Methyl-2-pentanone, Isopropylacetone

4 Aminophenazone; 4-Amino-2,3-dimethyl-1-phenyl-3-pyrazolin-5-one; Ampyrone

OD Plate is the measurement verification instrument for microplate photometer MPP-96 HiPo.

Reagents

ANILINE AR

Aminobenzene; Aminophen; Aniline oil; Benzenamine; Benzene,amino; Phenylamine

Dehydrated Media and Bases

Czapek Dox Agar

Platforms

Platform SV-16/8

16/8/8 sockets for 2*-1.5/0.5/0.2 ml microtest tubes (Ø 11/8/6 mm). *at 75% volume, max 3400 rpm

Products Best Selling

Sterile TPP TubeSpin® Bioreactor vessel, 50 ml, with pH and O2 sensor spots, 1 pce.

For the separation and purification of samples of cells, macromolecular proteins, blood, body fluids, DNA/RNA, plasmids, bacteria and viruses.

20 × 0.2 ml microtubes + 12 × 1.5 ml microtubes

The ES-20 is a compact bench–top Shaker–Incubator used for mixing of biological liquids as well as for incubation and cultivation of biological liquids according to the operator set program

New modular design of laboratory furniture provides flexibility and ease of use.

Contamination is especially problematic in the highly sensitive PCR technique. Originating from aerosolized fragments, contaminant DNA can lead to cross contamination thus resulting in inaccurate data and as a result misinterpreted analysis.

DNA/RNA UV-cleaner box UVC/T-M-AR is designed for clean operations with DNA samples. UV-cleaner box provide protection against contamination.

DNA/RNA UV-cleaner box UVT-B-AR is designed for clean operations with DNA samples. UV-Cabinet provide protection against contamination.

LN2 backup cooling system is an independent refrigeration system for a ULT freezer. When there is a loss of power or the temperature of the freezer rises to the high alarm set point, the LN2 backup system can be automatically activated to inject LN2 into the chamber to maintain the freezer temperature. The backup system operates on a rechargeable battery when there is a loss of main power.

Products Favourite

The new CAPPSolo single channel pipettes are built to meet the liquid-transfer needs of the modern laboratory. These dependable work-horses are the ideal micropipette for research, clinical and academic laboratories that require great quality without breaking the bank. Here are some brief highlights of what you can expect from these excellent mechanical pipettes.

This product has multiple variants. The options may be chosen on the product page

Applicable for blood stations, hospitals, CDC's, scientific research institutes, chemical industry and other related industries. The -30°C Biomedical Freezer can cryopreserve plasma, biological products, components, materials, and other items that need to be kept at low temperature.

This product has multiple variants. The options may be chosen on the product page

LN2 backup cooling system is an independent refrigeration system for a ULT freezer. When there is a loss of power or the temperature of the freezer rises to the high alarm set point, the LN2 backup system can be automatically activated to inject LN2 into the chamber to maintain the freezer temperature. The backup system operates on a rechargeable battery when there is a loss of main power.

A-12, adapter for work with tubes which are 12 mm in external diameter.

The ES-20 is a compact bench–top Shaker–Incubator used for mixing of biological liquids as well as for incubation and cultivation of biological liquids according to the operator set program

For the separation and purification of samples of cells, macromolecular proteins, blood, body fluids, DNA/RNA, plasmids, bacteria and viruses.

20 × 0.2 ml microtubes + 12 × 1.5 ml microtubes

Sterile TPP TubeSpin® Bioreactor vessel, 50 ml, with pH and O2 sensor spots, 1 pce.

This product is used in micro centrifugal scenarios (single tube capacity is less than or equal to 2ml)

This product has multiple variants. The options may be chosen on the product page

Cover of a unique sealed structure design provides a two-way guarantee and ensures the sealing property Conical thickened design at the bottom to increase the maximum centrifugal limit Max. centrifugal force: 7000 xg Tolerable temperature range: -80℃-120℃ Clear scale for accurate and convenient data reading Sterile and RNase, DNase, human DNA and Pyrogen Free

This product has multiple variants. The options may be chosen on the product page

The n-Safe Pro cabinets are designed, to provide superior operator and product protection according to EN-12469 and NSF/ANSI 49 The most versatile and popular model in the range, offering high performance, ergonomic design, quiet operation, and touchscreen. Ideal for routine and research labs.  

This product has multiple variants. The options may be chosen on the product page

UV Cleaner–Recirculator UVR-M

SKU: BS-040105-AAA Category: Brand:

Operation principle is based on a constant, forced air circulation through recirculator`s chamber in close vicinity to UV lamps, thus ensuring maximal efficiency of disinfection. The inner mirror surface of recirculator chamber reflects ultraviolet rays thereby increasing the density of UV radiation and enhancing the disinfection effect.

Biosan

UV Cleaner–Recirculator UVR-M
UV Cleaner–Recirculator UVR-M