Ingredients : gms/lit.
Pancreatic Digest of Casein 17.00
Soya Peptone 3.00
Sodium chloride 5.00
Dipotassium Hydrogen Phosphate 2.50
Glucose 2.50
Bile Salts No.3 1.50
Final pH (at 25°C) : 7.3 + 0.2

Directions :
Suspend 31.5 grams in 1000 ml distilled water. Heat to boiling to dissolve the medium completely.
Distribute 250 ml into flasks and sterilize by autoclaving at 15 lbs pressure (121°C) for 15 minutes.
Cool to 45-50oC and to each 250 ml flask add, under aseptic conditions Novobiocin supplement reconstituted with 2.0 ml of sterile distilled water.
Final concentration should be 20.0 mg/liter.

Principle :
The combination of Pancreatic Digest of Casein and Soya peptone makes these media nutritious by providing amino acids and long chain peptides for the growth of microorganisms. Dextrose and dipotassium phosphate serves as the carbohydrate source and the buffer in the medium. Sodium chloride maintains osmotic balance in both the media.

Packing

500 G

Recently Viewed

Photometers and Densitometers

Photometer DEN-600

DEN-600 is a compact, portable, rechargeable battery powered photometer. DEN-600 comprises of 600 nm wavelength optical system, which enables to apply - 1) OD600 method that estimated total number of cells, 2) McFarland (McF) turbidity measurement method, 3) Bradford protein assay method for protein concentration measurement, 4) other methods that can be adjusted or optimized using 600 nm wavelength.

This product is designed to store vaccines, blood plasma and many other biological materials. Suitable for scientific research institutes, blood stations, hospitals, centers for disease control and prevention, and material science, electronics and chemical laboratories.

This product has multiple variants. The options may be chosen on the product page

Platforms

Clamp HSC-100

Tight fit clamp 100 ml - Ø65 mm for UP-168.

NAA, Naphthalene-1-acetic acid

BioQuant-96 is the newest product of Biosan Molecular diagnostic product family.

The Milk Protein Rapid kit is a qualitative immunochromatographic lateral flow test designed for screening for the presence of milk protein residues in food products, ingredients, clean in place (CIP) final rinse water and environmental swabs. A control line assures the test is working properly, and the other two lines outline nondetectable, low, and high levels of milk protein.

Smart Biotherm Accessories

Rack for CPS-20 / CTR-6 installation RS2

Rack for CPS-20 / CTR-6 installation

Products Best Selling

Sterile TPP TubeSpin® Bioreactor vessel, 50 ml, with pH and O2 sensor spots, 1 pce.

For the separation and purification of samples of cells, macromolecular proteins, blood, body fluids, DNA/RNA, plasmids, bacteria and viruses.

20 × 0.2 ml microtubes + 12 × 1.5 ml microtubes

The ES-20 is a compact bench–top Shaker–Incubator used for mixing of biological liquids as well as for incubation and cultivation of biological liquids according to the operator set program

Applicable for storing wholeblood, medicines, biological products and other laboratory products that need to be stored at 4℃. Suitable for the storage of blood and blood articles in areas that have power shortages.

LN2 backup cooling system is an independent refrigeration system for a ULT freezer. When there is a loss of power or the temperature of the freezer rises to the high alarm set point, the LN2 backup system can be automatically activated to inject LN2 into the chamber to maintain the freezer temperature. The backup system operates on a rechargeable battery when there is a loss of main power.

A-12, adapter for work with tubes which are 12 mm in external diameter.

Products Favourite

Applicable for blood stations, hospitals, CDC's, scientific research institutes, chemical industry and other related industries. The -30°C Biomedical Freezer can cryopreserve plasma, biological products, components, materials, and other items that need to be kept at low temperature.

This product has multiple variants. The options may be chosen on the product page

LN2 backup cooling system is an independent refrigeration system for a ULT freezer. When there is a loss of power or the temperature of the freezer rises to the high alarm set point, the LN2 backup system can be automatically activated to inject LN2 into the chamber to maintain the freezer temperature. The backup system operates on a rechargeable battery when there is a loss of main power.

A-12, adapter for work with tubes which are 12 mm in external diameter.

The ES-20 is a compact bench–top Shaker–Incubator used for mixing of biological liquids as well as for incubation and cultivation of biological liquids according to the operator set program

For the separation and purification of samples of cells, macromolecular proteins, blood, body fluids, DNA/RNA, plasmids, bacteria and viruses.

20 × 0.2 ml microtubes + 12 × 1.5 ml microtubes

Sterile TPP TubeSpin® Bioreactor vessel, 50 ml, with pH and O2 sensor spots, 1 pce.

TRYPTIC SOYA BROTH MODIFIED

SKU: DM310 Category: