APPEARANCE REPORT
ASSAY % >= 99.5
COLOR APHA <= 10
EVAPORATION RESIDUE ppm <= 1
IDENTIFICATION PASS/FAIL = PASS TEST
IONIC IMPURITY - ALUMINUM (Al) ppb <= 20
IONIC IMPURITY - CALCIUM (Ca) ppb <= 50
IONIC IMPURITY - COPPER (Cu) ppb <= 10
IONIC IMPURITY - IRON (Fe) ppb <= 10
IONIC IMPURITY - LEAD (Pb) ppb <= 10
IONIC IMPURITY - MAGNESIUM (Mg) ppb <= 10
IONIC IMPURITY - MANGANESE (Mn) ppb <= 10
IONIC IMPURITY - NICKEL (Ni) ppb <= 10
IONIC IMPURITY - POTASSIUM (K) ppb <= 20
IONIC IMPURITY - SILVER (Ag) ppb <= 10
IONIC IMPURITY - SODIUM (Na) ppb <= 50
IONIC IMPURITY - ZINC (Zn) ppb <= 20
LC-MS GRADIENT SUITABILITY PASS/FAIL = PASS TEST
LC-UV GRADIENT SUITABILITY PASS/FAIL = PASS TEST
LCMS SUITABILITY - POS. MODE (AS PROPAZINE) ppb <= 50
OPTICAL ABS AT 210 NM ABS. UNITS <= 0.55
OPTICAL ABS AT 220 NM ABS. UNITS <= 0.18
OPTICAL ABS AT 230 NM ABS. UNITS <= 0.06
OPTICAL ABS AT 254 NM ABS. UNITS <= 0.003
OPTICAL ABS AT 275 NM ABS. UNITS <= 0.10
OPTICAL ABS AT 300 NM ABS. UNITS <= 0.06
WATER (H2O) % <= 0.05

CAS No.

76-05-1

Molecular Formula

C2HF3O2

Molecular Weight

114.02

HS Code

2915.9080

Symbol

GHS05, GHS07

Signal Word

Danger

UN No.

2699

IMCO Class No.

8

Hazardous Statement

H314-H332-H412

Precaution Statement

P280-P271-P260-P273-P264-P301+P330+P331-P305+P351+P338-P304+P340-P303+P361+P353-P363-P405-P501

Packing

50 ML

Recently Viewed

Nickel(II) chloride hexahydrate

Rotors

Rotor R-6

Swing-out rotor for conical bottom centrifuge tube. Aluminium buckets.

Reagents

CYCLOHEXANOL AR

Adronal; Cyclohexyl alcohol; Hexalin; Hexahydrophenol; Hydroxycyclohexane

Magnetic Stirrers, Overhead Stirrers

High speed magnetic stirrer MS-3000

MS-3000 is compact magnetic stirrer with stainless steel working surface. Units provide stirring of liquids with rotation speed of magnetic  element up to 3000 rpm. Currently it is the highest maximal speed for magnetic stirrers of global producers.

Reagents

NINHYDRIN AR

Indanetrione hydrate

Sodium (meta)vanadate; Sodium trioxovanadate; Sodium vanadate(V); Sodium vanadium oxide; Sodium vanadium trioxide

The Pine Nut Protein ELISA Kit is a microwell sandwich ELISA, used for the quantitative analysis of low levels of pine nut residues in food products, ingredients, clean in place (CIP) rinses and environmental swabs in a 96 well format. The quantity of protein in the sample can be extrapolated from the standard curve, constructed from standards of know concentration, and adjusted to consider the sample dilution.

N,N-Dimethylbenzenamine, Dimethylaminobenzene

Products Best Selling

Sterile TPP TubeSpin® Bioreactor vessel, 50 ml, with pH and O2 sensor spots, 1 pce.

For the separation and purification of samples of cells, macromolecular proteins, blood, body fluids, DNA/RNA, plasmids, bacteria and viruses.

20 × 0.2 ml microtubes + 12 × 1.5 ml microtubes

The ES-20 is a compact bench–top Shaker–Incubator used for mixing of biological liquids as well as for incubation and cultivation of biological liquids according to the operator set program

LN2 backup cooling system is an independent refrigeration system for a ULT freezer. When there is a loss of power or the temperature of the freezer rises to the high alarm set point, the LN2 backup system can be automatically activated to inject LN2 into the chamber to maintain the freezer temperature. The backup system operates on a rechargeable battery when there is a loss of main power.

Applicable for storing wholeblood, medicines, biological products and other laboratory products that need to be stored at 4℃. Suitable for the storage of blood and blood articles in areas that have power shortages.

A-12, adapter for work with tubes which are 12 mm in external diameter.

Products Favourite

LN2 backup cooling system is an independent refrigeration system for a ULT freezer. When there is a loss of power or the temperature of the freezer rises to the high alarm set point, the LN2 backup system can be automatically activated to inject LN2 into the chamber to maintain the freezer temperature. The backup system operates on a rechargeable battery when there is a loss of main power.

A-12, adapter for work with tubes which are 12 mm in external diameter.

The ES-20 is a compact bench–top Shaker–Incubator used for mixing of biological liquids as well as for incubation and cultivation of biological liquids according to the operator set program

For the separation and purification of samples of cells, macromolecular proteins, blood, body fluids, DNA/RNA, plasmids, bacteria and viruses.

20 × 0.2 ml microtubes + 12 × 1.5 ml microtubes

Sterile TPP TubeSpin® Bioreactor vessel, 50 ml, with pH and O2 sensor spots, 1 pce.

Applicable for blood stations, hospitals, CDC's, scientific research institutes, chemical industry and other related industries. The -30°C Biomedical Freezer can cryopreserve plasma, biological products, components, materials, and other items that need to be kept at low temperature.

This product has multiple variants. The options may be chosen on the product page

TRIFLUOROACETIC ACID MSCHROM FOR LC-MS CHROMATOGRAPHY

SKU: 301910050 Category: Brand:

TFA

Biochem Chemopharma

TRIFLUOROACETIC ACID MSCHROM FOR LC-MS CHROMATOGRAPHY
TRIFLUOROACETIC ACID MSCHROM FOR LC-MS CHROMATOGRAPHY