Assay (Alkalimetric) Min. 99%
Identity (IR spectrum) Passes test
UV Absorption (250 nm; 5%;
1cm; water) Max. 0.05
Chloride (Cl) Max. 0.005%
Sulfate (SO4) Max. 0.005%
Heavy metals (as Pb) Max. 0.005%
Sodium (Na) Max. 0.005%
Loss on drying (105°C)
Biological buffer, pKa at 20°C About 7.50

CAS No.

7365-44-8

Molecular Formula

C6H15NO6S

Molecular Weight

229.25

HS Code

2922.1990

Safety Statement

22-24/25

Packing

5 GM

Recently Viewed

Biosafety Air - UV - Cleaner Boxes

DNA/RNA Decontamination Solution PDS-250

Contamination is especially problematic in the highly sensitive PCR technique. Originating from aerosolized fragments, contaminant DNA can lead to cross contamination thus resulting in inaccurate data and as a result misinterpreted analysis.

Mechanical Pipettes

CAPPBravo Pipette

CAPPBravo automatic single-channel pipette combines lightweight ergonomic design with the latest innovations in single channel pipettes, making it one of the most user friendly automatic pipettes on the market today. CAPPBravo is both available as variable volume pipette (9 volume ranges starting from 0.1µl up to 10mL), as well as a fixed volume pipette. Constructed of the highest quality autoclavable materials, this mechanical pipette features feather light plunger and ejection forces, as well as smooth tip mounting. Ergonomically constructed hook ensures comfortable handling. The built-in oversized indicator makes volume monitoring and precise adjustment easy. CAPPBravo manual pipette offers ultra micro volumes with metal shafts and double o-rings to increase the durability of the pipettes. Experience CAPP’s symphony of precise measurements and see for yourself why it is called Bravo!

This product has multiple variants. The options may be chosen on the product page

1,4-Benzenediamine; 1,4-Diaminobenzene; 1,4-Phenylenediamine

Liquid Nitrogen Storage Solutions

CryoBio 6S

A new liquid nitrogen biological container - CryoBio 6S, with auto refill. Suitable for mid-to-high end biological sample storage requirements of laboratories, hospitals, sample banks and animal husbandry.

4-Hydroxypyrrolidin-2-carbonsäure

Freeze Dryer

Pilot Freeze Dryer

After the samples become freeze-dried preparations, they are more stable, especially for high temperature sensitive drugs, and most of them can be transported and stored at 0-4℃ or even normal temperature after freeze-dried, so the transportation and storage cost and inactivation risk are greatly reduced. Compared with traditional drying methods, the bioactive materials can restore their pre-freeze-dried conformation and biological function after redissolution. Therefore, freeze-drying is the safest method with the least impact on the properties of the drying materials.

Rotors

Rotor RMT-24

Fixed-angle rotor for 24 - 1.5 or 2 ml microtubes.

  • Nonsterile, universal fit, beveled pipette tips
  • Bulk bag of 1000 tips

Products Best Selling

Sterile TPP TubeSpin® Bioreactor vessel, 50 ml, with pH and O2 sensor spots, 1 pce.

For the separation and purification of samples of cells, macromolecular proteins, blood, body fluids, DNA/RNA, plasmids, bacteria and viruses.

20 × 0.2 ml microtubes + 12 × 1.5 ml microtubes

The ES-20 is a compact bench–top Shaker–Incubator used for mixing of biological liquids as well as for incubation and cultivation of biological liquids according to the operator set program

Applicable for storing wholeblood, medicines, biological products and other laboratory products that need to be stored at 4℃. Suitable for the storage of blood and blood articles in areas that have power shortages.

LN2 backup cooling system is an independent refrigeration system for a ULT freezer. When there is a loss of power or the temperature of the freezer rises to the high alarm set point, the LN2 backup system can be automatically activated to inject LN2 into the chamber to maintain the freezer temperature. The backup system operates on a rechargeable battery when there is a loss of main power.

A-12, adapter for work with tubes which are 12 mm in external diameter.

Products Favourite

Applicable for blood stations, hospitals, CDC's, scientific research institutes, chemical industry and other related industries. The -30°C Biomedical Freezer can cryopreserve plasma, biological products, components, materials, and other items that need to be kept at low temperature.

This product has multiple variants. The options may be chosen on the product page

LN2 backup cooling system is an independent refrigeration system for a ULT freezer. When there is a loss of power or the temperature of the freezer rises to the high alarm set point, the LN2 backup system can be automatically activated to inject LN2 into the chamber to maintain the freezer temperature. The backup system operates on a rechargeable battery when there is a loss of main power.

A-12, adapter for work with tubes which are 12 mm in external diameter.

The ES-20 is a compact bench–top Shaker–Incubator used for mixing of biological liquids as well as for incubation and cultivation of biological liquids according to the operator set program

For the separation and purification of samples of cells, macromolecular proteins, blood, body fluids, DNA/RNA, plasmids, bacteria and viruses.

20 × 0.2 ml microtubes + 12 × 1.5 ml microtubes

Sterile TPP TubeSpin® Bioreactor vessel, 50 ml, with pH and O2 sensor spots, 1 pce.

TES BUFFER FOR BIOCHEMISTRY

SKU: 220330005 Category: Brand:

N-tris (hydroxymethyl) Methyl-2-aminoethane Sulphonic Acid

Biochem Chemopharma

Placeholder
TES BUFFER FOR BIOCHEMISTRY