Ingredients : gms/lit.
Pancreatic Digest of Casein 17.00
Soya Peptone 3.00
Sodium chloride 5.00
Dipotassium Hydrogen Phosphate 2.50
Glucose 2.50
Bile Salts No.3 1.50
Final pH (at 25°C) : 7.3 + 0.2

Directions :
Suspend 31.5 grams in 1000 ml distilled water. Heat to boiling to dissolve the medium completely. Distribute 250 ml into flasks and sterilize by autoclaving at 15 lbs pressure (121°C) for 15 minutes. Cool to 45-50oC and to each 250 ml flask add, under aseptic conditions Novobiocin supplement reconstituted with 2.0 ml of sterile distilled water. Final concentration should be 20.0
mg/liter

Principle :
The combination of Pancreatic Digest of Casein and Soya peptone makes these media nutritious by providing amino acids and long chain peptides for the growth of microorganisms. Dextrose and dipotassium phosphate serves as the carbohydrate source and the buffer in the medium. Sodium chloride maintains osmotic balance in both the media

Packing

500 G

Recently Viewed

50 ml tubes with membrane filter TPP TubeSpin® Bioreactor 50, 20 pcs.

Blocks

Block B-2KF

Block for one deep-well plate PowerMag® Glass Bead Plate 96.

Centrifuge Adapters

Bucket adapters BA-14/2U

Bucket adapters for 14 microtest tubes of 2 ml (set of 4 pcs.).

200 μl - 96 pcs in stand

Vortexes, Homogenizer

Homogenizer RCP-24

Homogenizer RCP-24, a bench-top mechanical device designed for mixing, grinding, homogenizing and emulsifying biological objects in microtubes by shaking with hard beads for the purpose of sample preparation for subsequent academic, pharmaceutical, biotechnological or biomedical studies.

Photometers and Densitometers

Densitometer DEN-1B

Densitometer is designed for measurement of cell suspension's turbidity in the range of 0.0–6.0 McFarland units (0 – 180×107 cells/ml).

Consumables

PCR 96-Well Plates

Made of high-quality polypropylene material to avoid the liquid loss With a maximum volume of 0.3ml, it is suitable for 0.2ml PCR instruments The thin wall of the tube ensures uniform heat transfer and superior light transmittance The whole surface of the plate is smooth, firm, and non-deformation. RNase, DNase, human DNA and Pyrogen Free

This product has multiple variants. The options may be chosen on the product page

Rotors

Rotor R-24GC

Rotor for 24 Gel Cards for blood group serology testing (Forward Group, Reverse Group, RhD Type and 3 cell antibody screen).

Haier Biomedical Salvum brand of ULT freezers has been designed to deliver energy savings and reduced carbon footprint. This range uses environmentally safe hydrocarbon refrigerants and high efficiency fan motors to maximize the cooling ability of the system and reduce energy consumption. While providing sample safety, the freezer design makes energy savings possible for laboratories.

This product has multiple variants. The options may be chosen on the product page

Products Best Selling

Sterile TPP TubeSpin® Bioreactor vessel, 50 ml, with pH and O2 sensor spots, 1 pce.

For the separation and purification of samples of cells, macromolecular proteins, blood, body fluids, DNA/RNA, plasmids, bacteria and viruses.

20 × 0.2 ml microtubes + 12 × 1.5 ml microtubes

The ES-20 is a compact bench–top Shaker–Incubator used for mixing of biological liquids as well as for incubation and cultivation of biological liquids according to the operator set program

LN2 backup cooling system is an independent refrigeration system for a ULT freezer. When there is a loss of power or the temperature of the freezer rises to the high alarm set point, the LN2 backup system can be automatically activated to inject LN2 into the chamber to maintain the freezer temperature. The backup system operates on a rechargeable battery when there is a loss of main power.

Applicable for storing wholeblood, medicines, biological products and other laboratory products that need to be stored at 4℃. Suitable for the storage of blood and blood articles in areas that have power shortages.

A-12, adapter for work with tubes which are 12 mm in external diameter.

Products Favourite

Applicable for blood stations, hospitals, CDC's, scientific research institutes, chemical industry and other related industries. The -30°C Biomedical Freezer can cryopreserve plasma, biological products, components, materials, and other items that need to be kept at low temperature.

This product has multiple variants. The options may be chosen on the product page

LN2 backup cooling system is an independent refrigeration system for a ULT freezer. When there is a loss of power or the temperature of the freezer rises to the high alarm set point, the LN2 backup system can be automatically activated to inject LN2 into the chamber to maintain the freezer temperature. The backup system operates on a rechargeable battery when there is a loss of main power.

A-12, adapter for work with tubes which are 12 mm in external diameter.

The ES-20 is a compact bench–top Shaker–Incubator used for mixing of biological liquids as well as for incubation and cultivation of biological liquids according to the operator set program

For the separation and purification of samples of cells, macromolecular proteins, blood, body fluids, DNA/RNA, plasmids, bacteria and viruses.

20 × 0.2 ml microtubes + 12 × 1.5 ml microtubes

Sterile TPP TubeSpin® Bioreactor vessel, 50 ml, with pH and O2 sensor spots, 1 pce.

SOYBEAN CASEIN DIGEST MEDIUM (trypto casein soja)

SKU: DM2740500 Category: