Ingredients : gms/lit.
Pancreatic Digest of Casein 17.00
Soya Peptone 3.00
Sodium chloride 5.00
Dipotassium Hydrogen Phosphate 2.50
Glucose 2.50
Bile Salts No.3 1.50
Final pH (at 25°C) : 7.3 + 0.2

Directions :
Suspend 31.5 grams in 1000 ml distilled water. Heat to boiling to dissolve the medium completely. Distribute 250 ml into flasks and sterilize by autoclaving at 15 lbs pressure (121°C) for 15 minutes. Cool to 45-50oC and to each 250 ml flask add, under aseptic conditions Novobiocin supplement reconstituted with 2.0 ml of sterile distilled water. Final concentration should be 20.0
mg/liter

Principle :
The combination of Pancreatic Digest of Casein and Soya peptone makes these media nutritious by providing amino acids and long chain peptides for the growth of microorganisms. Dextrose and dipotassium phosphate serves as the carbohydrate source and the buffer in the medium. Sodium chloride maintains osmotic balance in both the media

Packing

500 G

Recently Viewed

Tips Consumables

Standard Tips

Made of medical-grade polypropylene (PP), the tips are high-temperature-resistant, high-pressure-resistant, and non-deformation; Optimized pore size ensures smooth sample suction; Three capacity options, respectively 10μl, 200μl and 1000μl, are available for both standard manual and electronic pipettors; Various packaging methods, including bulk packing and EO sterile racked packing; High clarity and perpendicularity ensure pipetting accuracy; RNase, DNase, human DNA and Pyrogen Free.

This product has multiple variants. The options may be chosen on the product page

(1-Hexadecyl)trimethylammonium bromide; Trimethylhexacecylammonium bromide; Cetrimonium Bromide; CTAB

2-(N,N-Dimethyl-4-aminophenyl)azobenzenecarboxylic acid, C.I. Acid Red 2

Reveal® 3-D for Total Milk offers results in just 5 minutes and can be used in virtually any environment to screen for milk residue (casein or whey) with environmental swabs, liquid products (such as juices and sorbet) and clean-in-place rinses. The Reveal 3-D line of food allergen tests kits is uniquely designed to guard against oversaturation and false negative results, with results displayed in three visual lines on the lateral flow test strip. A control line assures the test is working properly, and two other lines outline nondetectable, low, and high levels of total milk.

Calcined soda, Carbonic acid disodium salt, Soda ash

50 ml tubes with membrane filter TPP TubeSpin® Bioreactor 50, 20 pcs.

Products Best Selling

Sterile TPP TubeSpin® Bioreactor vessel, 50 ml, with pH and O2 sensor spots, 1 pce.

For the separation and purification of samples of cells, macromolecular proteins, blood, body fluids, DNA/RNA, plasmids, bacteria and viruses.

20 × 0.2 ml microtubes + 12 × 1.5 ml microtubes

The ES-20 is a compact bench–top Shaker–Incubator used for mixing of biological liquids as well as for incubation and cultivation of biological liquids according to the operator set program

Applicable for storing wholeblood, medicines, biological products and other laboratory products that need to be stored at 4℃. Suitable for the storage of blood and blood articles in areas that have power shortages.

LN2 backup cooling system is an independent refrigeration system for a ULT freezer. When there is a loss of power or the temperature of the freezer rises to the high alarm set point, the LN2 backup system can be automatically activated to inject LN2 into the chamber to maintain the freezer temperature. The backup system operates on a rechargeable battery when there is a loss of main power.

A-12, adapter for work with tubes which are 12 mm in external diameter.

Products Favourite

Applicable for blood stations, hospitals, CDC's, scientific research institutes, chemical industry and other related industries. The -30°C Biomedical Freezer can cryopreserve plasma, biological products, components, materials, and other items that need to be kept at low temperature.

This product has multiple variants. The options may be chosen on the product page

LN2 backup cooling system is an independent refrigeration system for a ULT freezer. When there is a loss of power or the temperature of the freezer rises to the high alarm set point, the LN2 backup system can be automatically activated to inject LN2 into the chamber to maintain the freezer temperature. The backup system operates on a rechargeable battery when there is a loss of main power.

A-12, adapter for work with tubes which are 12 mm in external diameter.

The ES-20 is a compact bench–top Shaker–Incubator used for mixing of biological liquids as well as for incubation and cultivation of biological liquids according to the operator set program

For the separation and purification of samples of cells, macromolecular proteins, blood, body fluids, DNA/RNA, plasmids, bacteria and viruses.

20 × 0.2 ml microtubes + 12 × 1.5 ml microtubes

Sterile TPP TubeSpin® Bioreactor vessel, 50 ml, with pH and O2 sensor spots, 1 pce.

SOYBEAN CASEIN DIGEST MEDIUM (trypto casein soja)