• Results in just 5 minutes
  • Easy-to-use lateral flow test strip — no equipment needed

Materials Provided

The Reveal 3-D for Peanut kit contains the following:

  1. 1 foil pouch, containing 10 orange Reveal 3-D Peanut Test devices
  2. 10 bottles or sachets containing Type 9 Extraction Buffer
  3. 10 sample tubes and caps
  4. 10 individually packaged, sterile swabs with break-off tips
  5. 1 bottle of swab wetting solution

Materials Required But Not Provided

The extraction of food samples requires the following:

  1. 3-D Food Buffer (Item Number 8504)
  2. Graduated 50 mL polypropylene test tubes (Item Number 9381)
Specifications
Brand Reveal®
Analyte Peanut
Platform Lateral Flow
Result Type Qualitative
Approvals AOAC-RI 111901
Limit of Detection Screens samples at 1.3 ppm peanut protein (5 ppm total peanut). Screens samples at 3-4 µg/100 cm2 peanut.
Testing Time 5.00
Quantity per Package 10 tests
Package Weight 0.50 lb

Documentation

SKUProductTypeLanguageFile
901041LReveal® 3-D for PeanutMaterial Safety Data SheetEnglishDownload
901041LReveal® 3-D for PeanutUser InstructionsEnglishDownload
901041LReveal® 3-D for PeanutUser ManualEnglishDownload

Related Products

Reveal® 3-D for Crustacea offers results in just 5 minutes and can be used in virtually any environment to screen environmental swabs and clean-in-place rinses. The Reveal 3-D line of food allergen tests kits is uniquely designed to guard against over-saturation and false negative results, with results displayed in three visual lines on the lateral flow test strip. A control line assures the test is working properly, and two other lines outline non-detectable, low, and high levels of crustacea.

Veratox for Gliadin is used for the quantitative analysis of prolamins (wheat gliadin, rye secalin, and barley hordein) in ingredients, environmental surfaces, clean-in-place rinses, and finished food products intended to be prolamins (gluten) free. Can also be used to screen environmental swabs.

Reveal 3-D for Gluten is Neogen’s new lateral flow gluten test that streamlines qualitative gluten testing and optimizes the users’ experience. This test offers a new testing method for measuring gluten content in both food products and ingredients. This test standardizes the test procedure into a simpler, easy to follow format, which facilitates your training and your process. This test also standardizes the detection limit of gluten, allowing for increased consistency. Combined with our industry-leading time to result, these enhancements allow for real-time decision making and rapid turnaround of product.

The Egg Protein Rapid kit is a qualitative immunochromatographic lateral flow test designed for screening for the presence of egg protein residues in food products, ingredients, clean in place (CIP) final rinse water and environmental swabs. A control line assures the test is working properly, and the other two lines outline nondetectable, low, and high levels of egg protein.

Veratox® for Soy Allergen is used for the quantitative analysis of soy residue in food products such as cookies, crackers, granola/power bars, ice cream, salad dressings, cereal, liquid products (e.g., juices and milk) and clean-in-place rinses. Can also be used to screen environmental swabs.

Veratox® for Almond Allergen is used for the quantitative analysis of almond residue in food products such as cookies, crackers, chocolate bars, ice cream, beverages and cereals. Can also be used to screen environmental swabs.

Veratox® VIP (Veratox Improvement Platform) for Walnut Allergen offers enhanced quantitative analysis of very low levels of raw and further-processed walnut residues in a wide variety of food products, ingredients, and clean-in-place rinses. This product can also be used to screen environmental swabs.

Reveal® for Multi-Treenut Test is intended for the qualitative analysis of treenut (almond, cashew, hazelnut, pecan, pistachio, and walnut) residue in clean-in-place rinses and on environmental surfaces.

Reveal® 3-D for Coconut offers results in just 5 minutes and can be used in virtually any environment to screen for coconut in liquid products (like UHT beverages, juices, drink flavours, etc.), clean-in-place rinses and environmental surfaces. The Reveal 3-D line of food allergen tests kits is uniquely designed to guard against over-saturation and false negative results, with results displayed in three visual lines on the lateral flow test strip. A control line assures the test is working properly, and two other lines outline non-detectable, low, and high levels of coconut.

Reveal® 3-D for Soy offers results in just 5 minutes and can be used in virtually any environment to screen environmental swabs and clean-in-place rinses. The Reveal 3-D line of food allergen tests kits is uniquely designed to guard against oversaturation and false negative results, with results displayed in three visual lines on the lateral flow test strip. A control line assures the test is working properly, and two other lines outline nondetectable, low, and high levels of soy.

Veratox® for Gliadin R5 is used for the quantitative analysis of ingredients, clean-in-place rinses and finished food products intended to be gluten free for the presence of gliadin and prolamins found in wheat, barley and rye. Can also be used to screen environmental swabs.

Veratox for Total Milk Allergen is used for the quantitative analysis of milk residue in food products and clean-in-place rinses. Can also be used to screen environmental swabs.

Recently Viewed

Reagents

BIURET AR

Allophanic acid amide, Carbamoylurea

Butanedioic acid disodium salt Succinic acid disodium salt

S)-2,5-Diamino-5-oxopentanoic acid, L-Glutamic acid 5-amide

Haier Biomedical LX-210L750R is a floor-standing highspeed refrigerated centrifuge features with 3L capacity and performance up to 47,400 x g, which is ideal for all-purpose use in the industrial and research sectors.

Backup System

LN2 Backup System

LN2 backup cooling system is an independent refrigeration system for a ULT freezer. When there is a loss of power or the temperature of the freezer rises to the high alarm set point, the LN2 backup system can be automatically activated to inject LN2 into the chamber to maintain the freezer temperature. The backup system operates on a rechargeable battery when there is a loss of main power.

Products Best Selling

For the separation and purification of samples of cells, macromolecular proteins, blood, body fluids, DNA/RNA, plasmids, bacteria and viruses.

Sterile TPP TubeSpin® Bioreactor vessel, 50 ml, with pH and O2 sensor spots, 1 pce.

20 × 0.2 ml microtubes + 12 × 1.5 ml microtubes

The ES-20 is a compact bench–top Shaker–Incubator used for mixing of biological liquids as well as for incubation and cultivation of biological liquids according to the operator set program

Applicable for storing wholeblood, medicines, biological products and other laboratory products that need to be stored at 4℃. Suitable for the storage of blood and blood articles in areas that have power shortages.

LN2 backup cooling system is an independent refrigeration system for a ULT freezer. When there is a loss of power or the temperature of the freezer rises to the high alarm set point, the LN2 backup system can be automatically activated to inject LN2 into the chamber to maintain the freezer temperature. The backup system operates on a rechargeable battery when there is a loss of main power.

A-12, adapter for work with tubes which are 12 mm in external diameter.

Products Favourite

Applicable for blood stations, hospitals, CDC's, scientific research institutes, chemical industry and other related industries. The -30°C Biomedical Freezer can cryopreserve plasma, biological products, components, materials, and other items that need to be kept at low temperature.

This product has multiple variants. The options may be chosen on the product page

LN2 backup cooling system is an independent refrigeration system for a ULT freezer. When there is a loss of power or the temperature of the freezer rises to the high alarm set point, the LN2 backup system can be automatically activated to inject LN2 into the chamber to maintain the freezer temperature. The backup system operates on a rechargeable battery when there is a loss of main power.

A-12, adapter for work with tubes which are 12 mm in external diameter.

The ES-20 is a compact bench–top Shaker–Incubator used for mixing of biological liquids as well as for incubation and cultivation of biological liquids according to the operator set program

For the separation and purification of samples of cells, macromolecular proteins, blood, body fluids, DNA/RNA, plasmids, bacteria and viruses.

20 × 0.2 ml microtubes + 12 × 1.5 ml microtubes

Sterile TPP TubeSpin® Bioreactor vessel, 50 ml, with pH and O2 sensor spots, 1 pce.

Reveal® 3-D for Peanut

SKU: 901041L Category: Brand:

Reveal® 3-D for Peanut offers results in just 5 minutes and can be used in virtually any environment to screen environmental swabs and clean-in-place rinses. The Reveal 3-D line of food allergen tests kits is uniquely designed to guard against oversaturation and false negative results, with results displayed in three visual lines on the lateral flow test strip. A control line assures the test is working properly, and two other lines outline nondetectable, low, and high levels of peanut.

Neogen

Reveal® 3-D for Peanut
Reveal® 3-D for Peanut