Assay (GC) Min 99.90 %
Water (KF) Max 0.02 %
Absorbance at 230 nm A.U Max. 0.05
Absorbance at 260 nm A.U Max 0.005
Absorbance at 230 nm Max 0.125
Absorbance of the largest eluted
peak
Max 0.5
Acidity/alkalinity (meq/g) Max 0.0002
LC-MS suitability Must be Pass
Filtered to 0.2 micron -
Appearance Clear colourless Mobile liquid
CAS No. | 67-56-1 |
---|---|
Molecular Formula | CH3OH |
Molecular Weight | 32.04 |
HS Code | 2905.1100 |
Symbol | GHS02, GHS06, GHS08 |
Signal Word | Danger |
UN No. | 1230 |
IMCO Class No. | 3, 6.1 |
Hazardous Statement | H301+H311+H331-H225-H370 |
Precaution Statement | P210-P280-P301+P310-P302+P352-P303+P361+P353-P304+P340-P370+P378-P501 |
Packing | 2.5 L |
Related Products
Recently Viewed
Vaccine Refrigerators and Freezers
The refrigerators are designed to store vaccines, freeze icepacks, pharmaceuticals etc and used within epidemic prevention, clinics, hospitals, research institutes etc.
This product has multiple variants. The options may be chosen on the product pageELISA Line
Plate Thermo–Shakers are designed for shaking and thermostating 4 standard 96–well microplates.
Allergens
- Nonsterile, universal fit, beveled pipette tips
- Contains 10 decks of 96 tips each
- Refill deck for Neogen PN 9407 pipette tip rack
Products Best Selling
Sterile TPP TubeSpin® Bioreactor vessel, 50 ml, with pH and O2 sensor spots, 1 pce.
For the separation and purification of samples of cells, macromolecular proteins, blood, body fluids, DNA/RNA, plasmids, bacteria and viruses.
The ES-20 is a compact bench–top Shaker–Incubator used for mixing of biological liquids as well as for incubation and cultivation of biological liquids according to the operator set program
Applicable for storing wholeblood, medicines, biological products and other laboratory products that need to be stored at 4℃. Suitable for the storage of blood and blood articles in areas that have power shortages.
LN2 backup cooling system is an independent refrigeration system for a ULT freezer. When there is a loss of power or the temperature of the freezer rises to the high alarm set point, the LN2 backup system can be automatically activated to inject LN2 into the chamber to maintain the freezer temperature. The backup system operates on a rechargeable battery when there is a loss of main power.
Products Favourite
LN2 backup cooling system is an independent refrigeration system for a ULT freezer. When there is a loss of power or the temperature of the freezer rises to the high alarm set point, the LN2 backup system can be automatically activated to inject LN2 into the chamber to maintain the freezer temperature. The backup system operates on a rechargeable battery when there is a loss of main power.
The ES-20 is a compact bench–top Shaker–Incubator used for mixing of biological liquids as well as for incubation and cultivation of biological liquids according to the operator set program
For the separation and purification of samples of cells, macromolecular proteins, blood, body fluids, DNA/RNA, plasmids, bacteria and viruses.
Sterile TPP TubeSpin® Bioreactor vessel, 50 ml, with pH and O2 sensor spots, 1 pce.
Applicable for blood stations, hospitals, CDC's, scientific research institutes, chemical industry and other related industries. The -30°C Biomedical Freezer can cryopreserve plasma, biological products, components, materials, and other items that need to be kept at low temperature.
This product has multiple variants. The options may be chosen on the product pageMETHANOL MSChrom For LC-MS Analysis
Methyl alcohol