Assay (GLC) % Min 99.9
Boiling range (95%) °C 64.1 - 65.1
Refractive index Ë 1.328 - 1.3296
Acidity meq/g Max 0.0005
Water (KF) ppm Max 300
Alkalinity meq/g Max 0.0002
Minimum transmission in 1cm cell at :
U.V. Transmittance
205 nm % 10
220 nm % 50
230 nm % 75
240 nm % 90
260 nm % 98
CAS No. | 67-56-1 |
---|---|
Molecular Formula | CH3OH |
Molecular Weight | 32.04 |
HS Code | 2905.1100 |
Symbol | GHS02, GHS06, GHS08 |
Signal Word | Danger |
UN No. | 1230 |
IMCO Class No. | 3, 6.1 |
Hazardous Statement | H301+H311+H331-H225-H370 |
Precaution Statement | P210-P280-P301+P310-P302+P352-P303+P361+P353-P304+P340-P370+P378-P501 |
Packing | 1 L |
Related Products
Recently Viewed
CleanTrace™ ALLTEC60 Surface Protein Swabs are a fast and easy way to visually check whether cleaning has been carried out to a satisfactory standard by means of protein detection. By comparing the color of the swab and solution against the label, the user can easily interpret the results for the presence of allergens. Clean-Trace® ALTEC60 Surface Protein (Allergen) Test Swab is validated for a range of allergenic proteins, including egg, milk, gluten, soy, peanut, almond and buckwheat. Refrigeration is not required -swabs can be stored at room temperature (25°C or 77°F). This easy-to-use device requires minimal training. The results are semi-quantitative with four possible color interpretations. The faster the test turns purple and the stronger the color change the higher the level of contamination on a surface Quick detection and confirmation allows immediate corrective action to take place. A visual reading of a color change indicates the level of cleanliness by detecting as little as 3µg of allergen on surfaces and in solution. No instrumentation is required to interpret the sample results. This product is easily integrated into company HACCP programs to monitor for cleaning effectiveness. Its ease of use, reliable detection and fast, visible results can help in teaching staff the importance of cleaning.
Reagents
Bismuth trinitrate pentahydrate; Bismuth(III) nitrate pentahydrate
Allergens
BioKits Peanut Assay Kit is used for the detection and quantification of peanut in foods and environmental swabs.
RTMD
Remote Temperature Recording: • The external temperature sensor measures the temperature, records and stores the measured temperature values automatically, and transmits them to the platform through GPRS, realizing remote platform monitoring. Application Scenarios: • It can be used for real-time monitoring of warehousing and distribution of food, medicine, vaccine, blood, reagents, biological products, biological sample tissue and other items. The application scenarios include refrigerated trucks, incubators, cold rooms, cold packs, refrigerated cabinets, refrigerators, freezers and so on.
Amplification and PCR
COVID-19 is a single-stranded, positive-sense RNA virus that caused a nationwide outbreak of serious respiratory problems across the world. This RNA virus is capable of person-to-person transmission, spreading very rapidly and afecting almost every country. It is genetically highly related to SARS and MERS coronaviruses.
Products Best Selling
For the separation and purification of samples of cells, macromolecular proteins, blood, body fluids, DNA/RNA, plasmids, bacteria and viruses.
Sterile TPP TubeSpin® Bioreactor vessel, 50 ml, with pH and O2 sensor spots, 1 pce.
The ES-20 is a compact bench–top Shaker–Incubator used for mixing of biological liquids as well as for incubation and cultivation of biological liquids according to the operator set program
Applicable for storing wholeblood, medicines, biological products and other laboratory products that need to be stored at 4℃. Suitable for the storage of blood and blood articles in areas that have power shortages.
LN2 backup cooling system is an independent refrigeration system for a ULT freezer. When there is a loss of power or the temperature of the freezer rises to the high alarm set point, the LN2 backup system can be automatically activated to inject LN2 into the chamber to maintain the freezer temperature. The backup system operates on a rechargeable battery when there is a loss of main power.
Products Favourite
Applicable for blood stations, hospitals, CDC's, scientific research institutes, chemical industry and other related industries. The -30°C Biomedical Freezer can cryopreserve plasma, biological products, components, materials, and other items that need to be kept at low temperature.
This product has multiple variants. The options may be chosen on the product pageLN2 backup cooling system is an independent refrigeration system for a ULT freezer. When there is a loss of power or the temperature of the freezer rises to the high alarm set point, the LN2 backup system can be automatically activated to inject LN2 into the chamber to maintain the freezer temperature. The backup system operates on a rechargeable battery when there is a loss of main power.
The ES-20 is a compact bench–top Shaker–Incubator used for mixing of biological liquids as well as for incubation and cultivation of biological liquids according to the operator set program
For the separation and purification of samples of cells, macromolecular proteins, blood, body fluids, DNA/RNA, plasmids, bacteria and viruses.
Sterile TPP TubeSpin® Bioreactor vessel, 50 ml, with pH and O2 sensor spots, 1 pce.
METHANOL FOR SPECTROSCOPY
Methyl alcohol