Amount of substance
concentration c(Hg) 1000 mg/L +/- 0.2%
Matrix 0.5 mol/L HNO3

CAS No.
HS Code

3822.0090

Symbol

GHS05, GHS08

Signal Word

Danger

UN No.

2922

IMCO Class No.

6.1, 8

Hazardous Statement

H311-H302-H412-H314-H373

Precaution Statement

P280-P301+P330+P331-P302+P352-P303+P361+P353-P304+P340-P305+P351+P338-P310-P501

Packing

500 ML

Recently Viewed

UV Cleaner - Recirculator Accessories

UVR-S stand

2',4',5',7'-Tetrabromo-4,5,6,7-tetrachlorofluorescein disodium salt, Acid Red 92, Cyanosine, Eosin 10B

Platforms

Clamp FC-2000

Clamp 2000 ml - Ø165 mm for UP-168

Turmeric Yellow,Natural yellow 3, Yellow Ginger, Golden Seal, Yellow Puccon,Indian Saffron

a-ketopropionic acid sodium salt; 2-oxopropanoic acid sodium salt; Pyruvic acid sodium salt;

Incubators

Standard Incubator

The solution is widely used in bacteria, fungi and other microorganisms culture; as well as enzyme digestion reaction, ligation reaction, embedded incubation and other related constant temperature experiments. Precise and stable operation With optional real-time IoT monitoring  

This product has multiple variants. The options may be chosen on the product page

N-Benzoylglycine; Benzoylaminoacetic acid

Products Best Selling

Sterile TPP TubeSpin® Bioreactor vessel, 50 ml, with pH and O2 sensor spots, 1 pce.

For the separation and purification of samples of cells, macromolecular proteins, blood, body fluids, DNA/RNA, plasmids, bacteria and viruses.

20 × 0.2 ml microtubes + 12 × 1.5 ml microtubes

The ES-20 is a compact bench–top Shaker–Incubator used for mixing of biological liquids as well as for incubation and cultivation of biological liquids according to the operator set program

Applicable for storing wholeblood, medicines, biological products and other laboratory products that need to be stored at 4℃. Suitable for the storage of blood and blood articles in areas that have power shortages.

LN2 backup cooling system is an independent refrigeration system for a ULT freezer. When there is a loss of power or the temperature of the freezer rises to the high alarm set point, the LN2 backup system can be automatically activated to inject LN2 into the chamber to maintain the freezer temperature. The backup system operates on a rechargeable battery when there is a loss of main power.

A-12, adapter for work with tubes which are 12 mm in external diameter.

Products Favourite

Applicable for blood stations, hospitals, CDC's, scientific research institutes, chemical industry and other related industries. The -30°C Biomedical Freezer can cryopreserve plasma, biological products, components, materials, and other items that need to be kept at low temperature.

This product has multiple variants. The options may be chosen on the product page

LN2 backup cooling system is an independent refrigeration system for a ULT freezer. When there is a loss of power or the temperature of the freezer rises to the high alarm set point, the LN2 backup system can be automatically activated to inject LN2 into the chamber to maintain the freezer temperature. The backup system operates on a rechargeable battery when there is a loss of main power.

A-12, adapter for work with tubes which are 12 mm in external diameter.

The ES-20 is a compact bench–top Shaker–Incubator used for mixing of biological liquids as well as for incubation and cultivation of biological liquids according to the operator set program

For the separation and purification of samples of cells, macromolecular proteins, blood, body fluids, DNA/RNA, plasmids, bacteria and viruses.

20 × 0.2 ml microtubes + 12 × 1.5 ml microtubes

Sterile TPP TubeSpin® Bioreactor vessel, 50 ml, with pH and O2 sensor spots, 1 pce.

MERCURY STANDARD SOLUTION FOR AAS – 1000 µG/mL IN HNO3

SKU: 312970500 Category: Brand:

Biochem Chemopharma

Placeholder
MERCURY STANDARD SOLUTION FOR AAS – 1000 µG/mL IN HNO3