LN2 backup cooling system is an independent refrigeration system for a ULT freezer. When there is a loss of power or the temperature of the freezer rises to the high alarm set point, the LN2 backup system can be automatically activated to inject LN2 into the chamber to maintain the freezer temperature. The backup system operates on a rechargeable battery when there is a loss of main power.

Features

● Interlocked design to turn off the LN2 injection when the door is opened

● Protection circuit to prevent over-charging battery

● Light weight and portable design, suitable for installation on top of a freezer

● Alarm functions to include low battery and sensor error

Model Cabinet Type Power Supply (V/Hz) Certificate Temperature Range (°C) Refrigerant
HBX-IIA Horizontal 115/60;208~230/60;220~240/50 CE;UL -90~-135 LN2

Documentation

SKUProductTypeLanguageFile
HBX-IIALN2 Backup SystemFlyerEnglishDownload

Related Products

Small footprint, light and easy for installation User adjustable temperature setting Simple to program and operate Flexible – Can be installed on any ULT freezer, which has a port hole The CO2 injection pipe is designed in combination of filter, to prevent the blockage of CO2 back-up system

Recently Viewed

Incubators

Standard Incubator

The solution is widely used in bacteria, fungi and other microorganisms culture; as well as enzyme digestion reaction, ligation reaction, embedded incubation and other related constant temperature experiments. Precise and stable operation With optional real-time IoT monitoring  

This product has multiple variants. The options may be chosen on the product page

Acetic acid 3-methylbutyl ester, Isoamyl acetate, Isopentyl acetate

Rhodamine 610, C.I. Pigment Violet 1, Basic Violet 10

Liquid Nitrogen Storage Solutions

Liquid Nitrogen Container-Smart Series

The smart, IoT and cloud management system monitors temperature and liquid levels simultaneously to provide accurate and real-time information on the critical parameters to ensure ultimate sample safety.

This product has multiple variants. The options may be chosen on the product page

High-speed mini-centrifuge Microspin 12 Plus is a compact desktop centrifuge designed for biomedical laboratories. Microspin 12 Plus is used for extracting RNA/DNA samples, sedimentation of biological components, biochemical and chemical analysis of microsamples.

Platforms

Platform PRS-14

14 tubes 20-30 mm diameter (50 ml tubes).

Products Best Selling

For the separation and purification of samples of cells, macromolecular proteins, blood, body fluids, DNA/RNA, plasmids, bacteria and viruses.

Sterile TPP TubeSpin® Bioreactor vessel, 50 ml, with pH and O2 sensor spots, 1 pce.

20 × 0.2 ml microtubes + 12 × 1.5 ml microtubes

The ES-20 is a compact bench–top Shaker–Incubator used for mixing of biological liquids as well as for incubation and cultivation of biological liquids according to the operator set program

Applicable for storing wholeblood, medicines, biological products and other laboratory products that need to be stored at 4℃. Suitable for the storage of blood and blood articles in areas that have power shortages.

LN2 backup cooling system is an independent refrigeration system for a ULT freezer. When there is a loss of power or the temperature of the freezer rises to the high alarm set point, the LN2 backup system can be automatically activated to inject LN2 into the chamber to maintain the freezer temperature. The backup system operates on a rechargeable battery when there is a loss of main power.

A-12, adapter for work with tubes which are 12 mm in external diameter.

Products Favourite

Applicable for blood stations, hospitals, CDC's, scientific research institutes, chemical industry and other related industries. The -30°C Biomedical Freezer can cryopreserve plasma, biological products, components, materials, and other items that need to be kept at low temperature.

This product has multiple variants. The options may be chosen on the product page

LN2 backup cooling system is an independent refrigeration system for a ULT freezer. When there is a loss of power or the temperature of the freezer rises to the high alarm set point, the LN2 backup system can be automatically activated to inject LN2 into the chamber to maintain the freezer temperature. The backup system operates on a rechargeable battery when there is a loss of main power.

A-12, adapter for work with tubes which are 12 mm in external diameter.

The ES-20 is a compact bench–top Shaker–Incubator used for mixing of biological liquids as well as for incubation and cultivation of biological liquids according to the operator set program

For the separation and purification of samples of cells, macromolecular proteins, blood, body fluids, DNA/RNA, plasmids, bacteria and viruses.

20 × 0.2 ml microtubes + 12 × 1.5 ml microtubes

Sterile TPP TubeSpin® Bioreactor vessel, 50 ml, with pH and O2 sensor spots, 1 pce.

LN2 Backup System

SKU: HBX-IIA Category: Brand:

LN2 backup cooling system is an independent refrigeration system for a ULT freezer. When there is a loss of power or the temperature of the freezer rises to the high alarm set point, the LN2 backup system can be automatically activated to inject LN2 into the chamber to maintain the freezer temperature. The backup system operates on a rechargeable battery when there is a loss of main power.

Haier Biomedical

LN2 Backup System
LN2 Backup System