LN2 backup cooling system is an independent refrigeration system for a ULT freezer. When there is a loss of power or the temperature of the freezer rises to the high alarm set point, the LN2 backup system can be automatically activated to inject LN2 into the chamber to maintain the freezer temperature. The backup system operates on a rechargeable battery when there is a loss of main power.

Features

● Interlocked design to turn off the LN2 injection when the door is opened

● Protection circuit to prevent over-charging battery

● Light weight and portable design, suitable for installation on top of a freezer

● Alarm functions to include low battery and sensor error

Model Cabinet Type Power Supply (V/Hz) Certificate Temperature Range (°C) Refrigerant
HBX-IIA Horizontal 115/60;208~230/60;220~240/50 CE;UL -90~-135 LN2

Documentation

SKUProductTypeLanguageFile
HBX-IIALN2 Backup SystemFlyerEnglishDownload

Related Products

Small footprint, light and easy for installation User adjustable temperature setting Simple to program and operate Flexible – Can be installed on any ULT freezer, which has a port hole The CO2 injection pipe is designed in combination of filter, to prevent the blockage of CO2 back-up system

Recently Viewed

1,2-Dihydroxyanthraquinone, Mordant Red 11

Photometers and Densitometers

Personal bioreactor RTS-1C

RTS-1C is personal bioreactor which utilize patented Reverse-Spin® technology that applies non-invasive, mechanically driven, low energy consumption, innovative type of agitation where cell suspension is mixed by the singleuse falcon bioreactor tube rotation around its axis with a change of direction of rotation motion resulting in highly efficient mixing and oxygenation for aerobic cultivation. Combined with a near-infrared optical system it is possible to register cell growth kinetics non-invasively in real time.

CleanTrace™ ALLTEC60 Surface Protein Swabs are a fast and easy way to visually check whether cleaning has been carried out to a satisfactory standard by means of protein detection. By comparing the color of the swab and solution against the label, the user can easily interpret the results for the presence of allergens. Clean-Trace® ALTEC60 Surface Protein (Allergen) Test Swab is validated for a range of allergenic proteins, including egg, milk, gluten, soy, peanut, almond and buckwheat. Refrigeration is not required -swabs can be stored at room temperature (25°C or 77°F). This easy-to-use device requires minimal training. The results are semi-quantitative with four possible color interpretations. The faster the test turns purple and the stronger the color change the higher the level of contamination on a surface Quick detection and confirmation allows immediate corrective action to take place. A visual reading of a color change indicates the level of cleanliness by detecting as little as 3µg of allergen on surfaces and in solution. No instrumentation is required to interpret the sample results. This product is easily integrated into company HACCP programs to monitor for cleaning effectiveness. Its ease of use, reliable detection and fast, visible results can help in teaching staff the importance of cleaning.

1,2,3-Propanetriol; Glycerin

Products Best Selling

Sterile TPP TubeSpin® Bioreactor vessel, 50 ml, with pH and O2 sensor spots, 1 pce.

For the separation and purification of samples of cells, macromolecular proteins, blood, body fluids, DNA/RNA, plasmids, bacteria and viruses.

20 × 0.2 ml microtubes + 12 × 1.5 ml microtubes

The ES-20 is a compact bench–top Shaker–Incubator used for mixing of biological liquids as well as for incubation and cultivation of biological liquids according to the operator set program

Applicable for storing wholeblood, medicines, biological products and other laboratory products that need to be stored at 4℃. Suitable for the storage of blood and blood articles in areas that have power shortages.

LN2 backup cooling system is an independent refrigeration system for a ULT freezer. When there is a loss of power or the temperature of the freezer rises to the high alarm set point, the LN2 backup system can be automatically activated to inject LN2 into the chamber to maintain the freezer temperature. The backup system operates on a rechargeable battery when there is a loss of main power.

A-12, adapter for work with tubes which are 12 mm in external diameter.

Products Favourite

Applicable for blood stations, hospitals, CDC's, scientific research institutes, chemical industry and other related industries. The -30°C Biomedical Freezer can cryopreserve plasma, biological products, components, materials, and other items that need to be kept at low temperature.

This product has multiple variants. The options may be chosen on the product page

LN2 backup cooling system is an independent refrigeration system for a ULT freezer. When there is a loss of power or the temperature of the freezer rises to the high alarm set point, the LN2 backup system can be automatically activated to inject LN2 into the chamber to maintain the freezer temperature. The backup system operates on a rechargeable battery when there is a loss of main power.

A-12, adapter for work with tubes which are 12 mm in external diameter.

The ES-20 is a compact bench–top Shaker–Incubator used for mixing of biological liquids as well as for incubation and cultivation of biological liquids according to the operator set program

For the separation and purification of samples of cells, macromolecular proteins, blood, body fluids, DNA/RNA, plasmids, bacteria and viruses.

20 × 0.2 ml microtubes + 12 × 1.5 ml microtubes

Sterile TPP TubeSpin® Bioreactor vessel, 50 ml, with pH and O2 sensor spots, 1 pce.

LN2 Backup System

SKU: HBX-IIA Category: Brand:

LN2 backup cooling system is an independent refrigeration system for a ULT freezer. When there is a loss of power or the temperature of the freezer rises to the high alarm set point, the LN2 backup system can be automatically activated to inject LN2 into the chamber to maintain the freezer temperature. The backup system operates on a rechargeable battery when there is a loss of main power.

Haier Biomedical

LN2 Backup System
LN2 Backup System