Labaqua ultrapure systems are multi-purpose water purification systems. The Labaqua systems produce ultrapure and pure water directly from tap water.

Labaqua HPLC produces water with very low organic carbon (TOC) content meeting requirements of liquid chromatography methods. Labaqua HPLC water can also be used for some microbiological and molecular biology applications.

Any configuration of a Labaqua ultrapure system produces both ultrapure and pure water. Ultrapure (Grade 1) water is dispensed through the point-of-use filter on the front panel. Pure (Grade 2) water is dispensed directly from the storage tank.

Labaqua ultrapure water can be used for the most demanding applications including, but not limited to: Inorganic trace analysis, Liquid chromatography, Cell culture, Molecular biology.

With resistivity of 18.2 Mega — Ohm*cm (0.055 μS/cm) ultrapure water produced by a Labaqua system exceeds requirements of all relevant standards (ISO 3696 Grade 1, ASTM Type I, CLSI Type I). Purified water is collected in a storage tank. An integrated recirculation system ensures consistent quality of water and reduces total organic carbon (TOC) to very low levels: <5ppb.

Pure water produced by the Labaqua systems complies with the requirements of ISO 3696 Grade 2 water and can be used for labware washing, wet chemistry methods, flame spectrophotometers, etc.

All Labaqua systems have a controller with a color graphic LCD display for water quality indication. The LCD display provides all necessary information about system status, as well as system flow-chart the remaining pre-filter life and deionization (DI) module performance. The smart DI module monitoring system also provides a reduction in running costs. A user is instructed to replace the DI module only when the module is near the end of its service life.

All cartridges and filters are easily accessible and no tools are required to replace them. The Labaqua system can be installed on a laboratory bench or mounted on a wall.

Features:

  • Volumetric dispense – enables the user to set accurate dispensing volume for each dispense cycle. The dispense volume can be set either from the keyboard or by using “teaching” mode.
  • Water quality – embedded recirculation loop ensures stable premium water quality and enables practical elimination of Total Organic Carbon (TOC).
  • Low running costs – performance of the deionization and polishing modules is constantly monitored. Monitoring algorithm enables cutting running costs, as replacement of the modules is requested only when service life is close to the end.
  • Total organic carbon (TOC) monitor – organic contaminants may not have effect on conductivity of water, so conductivity sensors cannot be used for TOC monitoring. Therefore, a special TOC monitoring module is needed to measure TOC level.
  • Color graphic LCD display – system component status is reflected on the display in an intuitive color pattern (Green/Yellow/Red).
  • System flowchart – shows all component status and water quality parameters at a glance.

The Labaqua systems include:

  • Boost pump
  • Pre-filter set
  • Reverse osmosis module
  • Deionization module
  • Final stage polishing module
  • 30L storage tank with an integrated Grade 2 dispensing valve
  • Recirculation system

Model specific modules:

  • Labaqua Trace – Point-of-use microfilter
  • Labaqua HPLC – Point-of-use microfilter, TOC monitor
  • Labaqua Bio – Point-of-use ultrafilter, UV sterilization module, TOC monitor

Compliance of the system with the technical specification is ensured if the following minimum tap water requirements are followed and the maintenance requirements specified in the user manual are carried out in a timely manner.

  • Type of feedwater: Potable
  • Minimum pressure: ≥ 0.5 bar
  • Maximum pressure: ≤ 5 bar
  • Conductivity: <1300 µS/cm
  • Temperature: 5 to 35°C
  • pH: 4 – 10
  • Fouling Index: <10
  • Iron: <0.1 ppm as CaCO3
  • Aluminum: <0.05 ppm as CaCO3
  • Manganese: <0.05 ppm as CaCO3
  • Free Chlorine: <1 ppm
  • Langerier Saturation Index: <+0.2
  • TOC: <2000 ppb
Ultrapure (Grade 1) water resistivity 18.2 MΩ x cm
Ultrapure (Grade 1) water conductivity 0.055 μS/cm
Pure (Grade 2) water resistivity 10 MΩ x cm
Pure (Grade 2) water conductivity 0.1 μS/cm
TOC < 5 ppb
Bacteria < 0.01 CFU/ml
Endotoxins < 0.15 EU/ml
Particles > 0.22 μm < 1/ml
Deionization module life (standard module) 1 m3
Storage tank 30 l
Feed water pressure 0.5 – 5 bar
Feed water conductivity < 1300 μS/cm
Dimensions (W×D×H) 320×560×620 mm
Weight 25 kg
Power consumption 130 W
Nominal operating voltage 100-240VAC 50/60Hz

Accessories

Documentation

SKUProductTypeLanguageFile
Labaqua HPLCLabaqua HPLCDeclaration of ConformityEnglishDownload
Labaqua HPLCLabaqua HPLCBrochureEnglishDownload
Labaqua HPLCLabaqua HPLCUser InstructionsEnglishDownload

General Documents

TypeNameLanguageFile
CatalogueEnglishDownload
Weight 25 kg
Dimensions 320 × 560 × 620 mm

Related Products

Labaqua ultrapure systems are multi-purpose water purification systems. The Labaqua systems produce ultrapure and pure water directly from tap water.

Labaqua ultrapure systems are multi-purpose water purification systems. The Labaqua systems produce ultrapure and pure water directly from tap water.

This product has multiple variants. The options may be chosen on the product page

Recently Viewed

Acetic Acid Methyl Ester

CleanTrace™ ALLTEC60 Surface Protein Swabs are a fast and easy way to visually check whether cleaning has been carried out to a satisfactory standard by means of protein detection. By comparing the color of the swab and solution against the label, the user can easily interpret the results for the presence of allergens. Clean-Trace® ALTEC60 Surface Protein (Allergen) Test Swab is validated for a range of allergenic proteins, including egg, milk, gluten, soy, peanut, almond and buckwheat. Refrigeration is not required -swabs can be stored at room temperature (25°C or 77°F). This easy-to-use device requires minimal training. The results are semi-quantitative with four possible color interpretations. The faster the test turns purple and the stronger the color change the higher the level of contamination on a surface Quick detection and confirmation allows immediate corrective action to take place. A visual reading of a color change indicates the level of cleanliness by detecting as little as 3µg of allergen on surfaces and in solution. No instrumentation is required to interpret the sample results. This product is easily integrated into company HACCP programs to monitor for cleaning effectiveness. Its ease of use, reliable detection and fast, visible results can help in teaching staff the importance of cleaning.

Propenoic Acid Ethylenecarboxylic Acid

Centrifuge Adapters

Adapter A-02

Adapter 12 pieces for microtubes 0.2 ml

Suitable for blood transfusion departments, operating rooms, and emergency rooms, etc. of the hospitals.

Reagents

BRIJ 30

Polyoxyethylene(4) lauryl ether; Dodecyl tetraethylene glycol ether; Tetraethylene glycol dodecyl ether; Tetraethylene glycol lauryl ether; Tetraoxyethylene glycol monododecyl ether

Products Best Selling

Sterile TPP TubeSpin® Bioreactor vessel, 50 ml, with pH and O2 sensor spots, 1 pce.

For the separation and purification of samples of cells, macromolecular proteins, blood, body fluids, DNA/RNA, plasmids, bacteria and viruses.

20 × 0.2 ml microtubes + 12 × 1.5 ml microtubes

The ES-20 is a compact bench–top Shaker–Incubator used for mixing of biological liquids as well as for incubation and cultivation of biological liquids according to the operator set program

Applicable for storing wholeblood, medicines, biological products and other laboratory products that need to be stored at 4℃. Suitable for the storage of blood and blood articles in areas that have power shortages.

LN2 backup cooling system is an independent refrigeration system for a ULT freezer. When there is a loss of power or the temperature of the freezer rises to the high alarm set point, the LN2 backup system can be automatically activated to inject LN2 into the chamber to maintain the freezer temperature. The backup system operates on a rechargeable battery when there is a loss of main power.

A-12, adapter for work with tubes which are 12 mm in external diameter.

Products Favourite

20 × 0.2 ml microtubes + 12 × 1.5 ml microtubes

Sterile TPP TubeSpin® Bioreactor vessel, 50 ml, with pH and O2 sensor spots, 1 pce.

Applicable for blood stations, hospitals, CDC's, scientific research institutes, chemical industry and other related industries. The -30°C Biomedical Freezer can cryopreserve plasma, biological products, components, materials, and other items that need to be kept at low temperature.

This product has multiple variants. The options may be chosen on the product page

LN2 backup cooling system is an independent refrigeration system for a ULT freezer. When there is a loss of power or the temperature of the freezer rises to the high alarm set point, the LN2 backup system can be automatically activated to inject LN2 into the chamber to maintain the freezer temperature. The backup system operates on a rechargeable battery when there is a loss of main power.

A-12, adapter for work with tubes which are 12 mm in external diameter.

The ES-20 is a compact bench–top Shaker–Incubator used for mixing of biological liquids as well as for incubation and cultivation of biological liquids according to the operator set program

For the separation and purification of samples of cells, macromolecular proteins, blood, body fluids, DNA/RNA, plasmids, bacteria and viruses.

Ultrapure water system Labaqua HPLC

SKU: BS-070104-A02 Category: Brand:

Labaqua ultrapure systems are multi-purpose water purification systems. The Labaqua systems produce ultrapure and pure water directly from tap water.

Biosan

Ultrapure water system Labaqua HPLC
Ultrapure water system Labaqua HPLC