High Processing Efficiency

  • Fully automated, non-contact sampling technology to endure the safety of operators, environments, and samples processing
  • 24-hour operation to solve 10 thousand samples daily

Traceable Sample Information

  • Equipped with scanning code module compatible with bar code and two-dimensional code, automatic identification and tracking sample information
  • High-resolution camera distinguishes swab and liquid level, to ensure aspiration accuracy
  • Mixing the samples well

Flexible and Compatible

  • Compatible with 5ml, 10ml and sample tubes with screw cap for multiple brands
  • Supports mixed sample processing
  • Supports the pr ocessing of different sample tubes at one time
  • Compatible with 16/24/32/48/96 well plate f or DNA extraction

Safe and Reliable

  • HEPA filtration system + UV lamp disinfection
  • Aerosol filtration efficiency over 99.995%
  • Efficient visual identification system, capability to flag abnormal samples
Model Net dimensions (W*D*H)(mm) Processing speed Pipetting range Pipetting precision Pipetting accuracy UV Ultraviolet radiator Negative pressure HEPA system
FB-1000 Product 1100*680*1080 1 sample/20 seconds, 96 samples/32 minutes 10μl~1000μl 10μlCV≤5%;100μlCV≤3%;1000μlCV≤1% 10μl±10%;100μl±2%;1000μl±1% 15W Aerosol filtration efficiency 99.995% at 0.3um
FB-1000H Product 1100*680*1080,Workbench 1050*650*900 1 sample/20 seconds, 96 samples/32 minutes 10μl~1000μl 10μlCV≤5%;100μlCV≤3%;1000μlCV≤1% 10μl±10%;100μl±2%;1000μl±1% 15W Aerosol filtration efficiency 99.995% at 0.3um

Documentation

SKUProductTypeLanguageFile
FlyerEnglishDownload
Model

FB-1000, FB-1000H

Related Products

Recently Viewed

DNA and RNA Purification

Dry block thermostat TDB-120

TDB-120 is a traditional Biosan’s dry block thermostat for laboratory analysis. Thermostat is designed for maintaining constant temperature of samples in tubes inserted in the aluminium block sockets. Unprecedented high precision and uniformity of temperature over the block. TDB-120 is widely used for PCR–analysis.

This product has multiple variants. The options may be chosen on the product page

Blocks

Block B-2N

Block for one deep-well plate Nunc® 96/2000 μl

Thermo–Shaker TS-100C Smart provides intensive mixing and temperature control of samples in microtest tubes or PCR plate. This model of Thermo–Shaker differs from TS-100 with a possibility of cooling samples down to +4°C and with control up to 7 units from PC via Bluetooth® technology.

The double door -40℃ biomedical freezer models offer a large capacity storage space with rapid cooling. Integrated design of cold shelf and evaporator provides additional refrigeration efficiency. Designed to store vaccines, blood plasma and many other biological materials. Installations can be found in research institutions and clinical sites in the life science, pharma, biotech, medical and electronics sectors.

This product has multiple variants. The options may be chosen on the product page

Platforms

Clamp FC-50

Clamp 50 ml - Ø50 mm for UP-168

Zinc(II) chloride; Zinc dichloride; Butter of zinc

BASIC BLUE 20, 4-[[4-(Dimethylamino)phenyl][4-(dimethyliminio)cyclohexa-2,5-dien-1-ylidene]methyl]-N,N,N-trimethylanilinium dichloride

Ammonium iron (III) sulphate dodecahydrate

Health Care Products

Air Purification Sterilizer

Bacterial and viruses inactivation rate>99. 9% to reduce the infection rate of the vaccination staff; can reach class 100000 cleanliness after continuously operating for 1 hour, and release healthy negative ions, providing clean air for users to experience forest air quality. Applicable for schools, community hospitals, etc.

Basic Blue 17; Tolonium chloride; Blutene chloride; Basic Blue 17; Gabilin; Menodin

Products Best Selling

Sterile TPP TubeSpin® Bioreactor vessel, 50 ml, with pH and O2 sensor spots, 1 pce.

For the separation and purification of samples of cells, macromolecular proteins, blood, body fluids, DNA/RNA, plasmids, bacteria and viruses.

20 × 0.2 ml microtubes + 12 × 1.5 ml microtubes

The ES-20 is a compact bench–top Shaker–Incubator used for mixing of biological liquids as well as for incubation and cultivation of biological liquids according to the operator set program

Applicable for storing wholeblood, medicines, biological products and other laboratory products that need to be stored at 4℃. Suitable for the storage of blood and blood articles in areas that have power shortages.

LN2 backup cooling system is an independent refrigeration system for a ULT freezer. When there is a loss of power or the temperature of the freezer rises to the high alarm set point, the LN2 backup system can be automatically activated to inject LN2 into the chamber to maintain the freezer temperature. The backup system operates on a rechargeable battery when there is a loss of main power.

A-12, adapter for work with tubes which are 12 mm in external diameter.

Products Favourite

LN2 backup cooling system is an independent refrigeration system for a ULT freezer. When there is a loss of power or the temperature of the freezer rises to the high alarm set point, the LN2 backup system can be automatically activated to inject LN2 into the chamber to maintain the freezer temperature. The backup system operates on a rechargeable battery when there is a loss of main power.

A-12, adapter for work with tubes which are 12 mm in external diameter.

The ES-20 is a compact bench–top Shaker–Incubator used for mixing of biological liquids as well as for incubation and cultivation of biological liquids according to the operator set program

For the separation and purification of samples of cells, macromolecular proteins, blood, body fluids, DNA/RNA, plasmids, bacteria and viruses.

20 × 0.2 ml microtubes + 12 × 1.5 ml microtubes

Sterile TPP TubeSpin® Bioreactor vessel, 50 ml, with pH and O2 sensor spots, 1 pce.

Applicable for blood stations, hospitals, CDC's, scientific research institutes, chemical industry and other related industries. The -30°C Biomedical Freezer can cryopreserve plasma, biological products, components, materials, and other items that need to be kept at low temperature.

This product has multiple variants. The options may be chosen on the product page

Fully-automated Sample Processing System

SKU: N/A Category: Brand:

The a utomated sample processing system supports automatically uncapping, dispensing and recapping at one time. It can complete the aspiration of 96 samples from the original tubes or cryopreservation tubes to the deep-well multiwell plate, cell culture plate or PCR plate in 32 minutes in a single channel pipetting mode.

Haier Biomedical

Fully-automated Sample Processing System
Fully-automated Sample Processing System
Select options