DNA/RNA UV-cleaner box UVT-B-AR is designed for clean operations with DNA samples. UV-Cabinet provide protection against contamination.

Model is a bench-top type, made of metal framework, working surface made of stainless steel.

UV-cleaner boxes are equipped with an open UV lamp installed in the upper hood. UV-radiation from the open lamps disinfects the working area inactivating DNA/RNA fragments during 15–30 min of exposure. A digital timer controls duration of the direct UV irradiation. A daylight lamp provides proper illumination of the working surface.

UV-cleaner boxes are equipped with a flow-type bactericidal UV cleaner–recirculator AR, which provides constant decontamination inside the cabinet during operation. They are recommended for operations with DNA/RNA amplicons.

UV cleaner–recirculator AR consists of a UV lamp, a fan and dust filters organized in a special body so that a user working with a UV-cleaner box is protected against UV light. Recirculator increases the maximum density of UV light making it  sufficiently effective for DNA/RNA inactivation. The UV–recirculator processes 100 UV-cleaner box volumes per hour, creating permanent aseptic conditions of operation inside the UV-cleaner box.

Specially assigned moving tables T-4 (with wheel locks) with a drawer are available on request.

Advantages of Biosan UV-cleaner boxes:

  • Ozone free high density UV decontamination
  • Long living UV lamps (9,000 hours average)
  • Automatic switch off of UV-lamps when the protective screen is opened
  • Bactericidal flow-type recirculator providing permanent decontamination inside UV–cabinet during operation
  • Shockproof glass walls
  • Low noise, low energy consumption
  • Tables for installation of UV-cleaner boxes
  • UV-cleaner boxes with the bactericidal UV cleaner–recirculator AR is the patented Biosan solution

Specification:

Walls material Rear: stainless steel, Sides: steel with chemical resistant powder coating Front: glass (EUROGLASS, Germany)
Working surface material Stainless steel
Open UV-lamp 1 x 25W built‑in bactericidal UV-C, TUV 25W 1SL/25
UV radiation level 18 mW / cm2 / sec
Radiation type UV (λ = 253.7 nm), ozone-free
Digital time setting of direct UV exposure 1 min–24 hrs / non–stop (increment 1 min)
UV-recirculator 1x25W (efficiency >99% per 1 hour)
Daylight lamp (for working area illumination) 1 x TLD-15W
Thickness of side panels 2 mm
Thickness of upper front panel 8 mm
Thickness of screen 4 mm
Optical transmission 95%
UV protection >96%, UV-protection film
Working area 645 × 490 mm
Opening dimensions (fully raised protective screen) 645 × 190 mm
Safety features Automatic open UV-lamp switch off when screen is open
Power outlets inside the unit Inlet for power cords and 1x Built-in socket, max. 1000 W
Overall dimensions (W×D×H) 700 × 580 × 555 mm
Weight (net / gross) 31.2 / 42 kg
Power consumption 67 W
Nominal operating voltage 100-240 V, 50/60Hz
Optional table T-4 (800 × 600 × 770 mm)

Specification

Specification

Accessories

New modular design of laboratory furniture provides flexibility and ease of use.

New modular design of laboratory furniture provides flexibility and ease of use.

Contamination is especially problematic in the highly sensitive PCR technique. Originating from aerosolized fragments, contaminant DNA can lead to cross contamination thus resulting in inaccurate data and as a result misinterpreted analysis.

Contamination is especially problematic in the highly sensitive PCR technique. Originating from aerosolized fragments, contaminant DNA can lead to cross contamination thus resulting in inaccurate data and as a result misinterpreted analysis.

Weight 31,2 kg
Dimensions 700 × 580 × 555 mm
Product class

Basic Plus

Related Products

DNA/RNA UV-cleaner box UVC/T-M-AR is designed for clean operations with DNA samples. UV-cleaner box provide protection against contamination.

Operation principle is based on a constant, forced air circulation through recirculator`s chamber in close vicinity to UV lamps, thus ensuring maximal efficiency of disinfection. The inner mirror surface of recirculator chamber reflects ultraviolet rays thereby increasing the density of UV radiation and enhancing the disinfection effect.

Operation principle is based on a constant, forced air circulation through recirculator`s chamber in close vicinity to UV lamps, thus ensuring maximal efficiency of disinfection. The inner mirror surface of recirculator chamber reflects ultraviolet rays thereby increasing the density of UV radiation and enhancing the disinfection effect.

DNA/RNA UV-cleaner box UVT-S-AR is designed for clean operations with DNA samples. UV-cleaner box provide protection against contamination.

Contamination is especially problematic in the highly sensitive PCR technique. Originating from aerosolized fragments, contaminant DNA can lead to cross contamination thus resulting in inaccurate data and as a result misinterpreted analysis.

Contamination is especially problematic in the highly sensitive PCR technique. Originating from aerosolized fragments, contaminant DNA can lead to cross contamination thus resulting in inaccurate data and as a result misinterpreted analysis.

Recently Viewed

Reagents

ANILINE AR

Aminobenzene; Aminophen; Aniline oil; Benzenamine; Benzene,amino; Phenylamine

Washers, Aspirators

Intelispeed washer IW-8

Intelispeed Washer IW-8 is designed for washing of standard flat-bottom 96 well plates and microstrips. The unit is fully programmable ensuring multi-step solution ripening, aspiration (aspiration, combination of aspiration/liquid dispensing and soaking, as well as soaking cycle during a particular period of time).

4 Aminophenazone; 4-Amino-2,3-dimethyl-1-phenyl-3-pyrazolin-5-one; Ampyrone

Ammonium iron (III) sulphate dodecahydrate

Plasma Blast Freezer

Plasma Blast Freezer

Mainly intended for the quick-frozen treatment of blood plasma or biological samples to a core below -30°C within 1 hour in blood stations or medical institutions.

This product has multiple variants. The options may be chosen on the product page

Products Best Selling

For the separation and purification of samples of cells, macromolecular proteins, blood, body fluids, DNA/RNA, plasmids, bacteria and viruses.

Sterile TPP TubeSpin® Bioreactor vessel, 50 ml, with pH and O2 sensor spots, 1 pce.

20 × 0.2 ml microtubes + 12 × 1.5 ml microtubes

Applicable for storing wholeblood, medicines, biological products and other laboratory products that need to be stored at 4℃. Suitable for the storage of blood and blood articles in areas that have power shortages.

The ES-20 is a compact bench–top Shaker–Incubator used for mixing of biological liquids as well as for incubation and cultivation of biological liquids according to the operator set program

LN2 backup cooling system is an independent refrigeration system for a ULT freezer. When there is a loss of power or the temperature of the freezer rises to the high alarm set point, the LN2 backup system can be automatically activated to inject LN2 into the chamber to maintain the freezer temperature. The backup system operates on a rechargeable battery when there is a loss of main power.

A-12, adapter for work with tubes which are 12 mm in external diameter.

Products Favourite

Applicable for blood stations, hospitals, CDC's, scientific research institutes, chemical industry and other related industries. The -30°C Biomedical Freezer can cryopreserve plasma, biological products, components, materials, and other items that need to be kept at low temperature.

This product has multiple variants. The options may be chosen on the product page

LN2 backup cooling system is an independent refrigeration system for a ULT freezer. When there is a loss of power or the temperature of the freezer rises to the high alarm set point, the LN2 backup system can be automatically activated to inject LN2 into the chamber to maintain the freezer temperature. The backup system operates on a rechargeable battery when there is a loss of main power.

A-12, adapter for work with tubes which are 12 mm in external diameter.

The ES-20 is a compact bench–top Shaker–Incubator used for mixing of biological liquids as well as for incubation and cultivation of biological liquids according to the operator set program

For the separation and purification of samples of cells, macromolecular proteins, blood, body fluids, DNA/RNA, plasmids, bacteria and viruses.

20 × 0.2 ml microtubes + 12 × 1.5 ml microtubes

Sterile TPP TubeSpin® Bioreactor vessel, 50 ml, with pH and O2 sensor spots, 1 pce.

DNA/RNA UV-cleaner box UVT-B-AR

SKU: BS-040109-A06 Category: Brand:

DNA/RNA UV-cleaner box UVT-B-AR is designed for clean operations with DNA samples. UV-Cabinet provide protection against contamination.

Biosan

DNA/RNA UV-cleaner box UVT-B-AR
DNA/RNA UV-cleaner box UVT-B-AR