Assay (GLC) Min 99.9 %
Identification Positive
Density at 20° C 1.322 ÷ 1.328
Refractive index at 20°C 1.4214 ÷ 1.4274
Boiling point 39.6 ÷ 40.1°C
Acidity Max 0.0001
Water (K.F.) Max 0.01 % meq/g
Residue on evaporation Max 0.0002 %
U.V. Transmittance -
At 235 nm Min 40 %
at 240 nm Min 70 %
at 250 nm Min 96 %
at 260 nm Min 99 %
Amylene Max 0.006 %
Alkalinity Max 0.0002
Appearance Clear colourless liquid meq/g

CAS No.

75-09-2

Molecular Formula

CH2CI2

Molecular Weight

84.93

HS Code

2903.1200

Symbol

GHS07, GHS08

Signal Word

Warning

UN No.

1593

IMCO Class No.

6.1

Hazardous Statement

H351

Precaution Statement

P201-P202-P308+P313-P405-P501

Packing

1 L

Recently Viewed

o-Cresolphthalein-3',3''-bis-methyleneiminodiacetic acid; o-Cresolphthalexon; Metal phthalein; Phthalein purple; Xylenylphthalein-bisiminodiacetic acid

Rockers, Shakers and Rotators

Programmable rotator Multi RS-60

Programmable Rotator Multi RS-60 performs several motion types in one module. Microprocessor control allows performing not only Vertical rotation (1) of the platform, but also Reciprocal rotation (2) as well as Vibration (3). These three motion types can be performed separately,  pairwise and in cycles, periodically repeating the sequence of three motion types.

Centrifuge Adapters

Adapter set BN-11/30

Spare adapter set for rotor R-6P. Plastic buckets (POM Kocetal) (6 pcs).

Blocks

Block SC-18

20 × 0.5 ml + 12 × 1.5 ml microtubes

Ammonium iron (III) sulphate dodecahydrate

(S)-Pyrrolidine-2-carboxylic acid

Products Best Selling

Sterile TPP TubeSpin® Bioreactor vessel, 50 ml, with pH and O2 sensor spots, 1 pce.

For the separation and purification of samples of cells, macromolecular proteins, blood, body fluids, DNA/RNA, plasmids, bacteria and viruses.

20 × 0.2 ml microtubes + 12 × 1.5 ml microtubes

The ES-20 is a compact bench–top Shaker–Incubator used for mixing of biological liquids as well as for incubation and cultivation of biological liquids according to the operator set program

New modular design of laboratory furniture provides flexibility and ease of use.

Contamination is especially problematic in the highly sensitive PCR technique. Originating from aerosolized fragments, contaminant DNA can lead to cross contamination thus resulting in inaccurate data and as a result misinterpreted analysis.

DNA/RNA UV-cleaner box UVC/T-M-AR is designed for clean operations with DNA samples. UV-cleaner box provide protection against contamination.

DNA/RNA UV-cleaner box UVT-B-AR is designed for clean operations with DNA samples. UV-Cabinet provide protection against contamination.

LN2 backup cooling system is an independent refrigeration system for a ULT freezer. When there is a loss of power or the temperature of the freezer rises to the high alarm set point, the LN2 backup system can be automatically activated to inject LN2 into the chamber to maintain the freezer temperature. The backup system operates on a rechargeable battery when there is a loss of main power.

Products Favourite

The new CAPPSolo single channel pipettes are built to meet the liquid-transfer needs of the modern laboratory. These dependable work-horses are the ideal micropipette for research, clinical and academic laboratories that require great quality without breaking the bank. Here are some brief highlights of what you can expect from these excellent mechanical pipettes.

This product has multiple variants. The options may be chosen on the product page

Applicable for blood stations, hospitals, CDC's, scientific research institutes, chemical industry and other related industries. The -30°C Biomedical Freezer can cryopreserve plasma, biological products, components, materials, and other items that need to be kept at low temperature.

This product has multiple variants. The options may be chosen on the product page

LN2 backup cooling system is an independent refrigeration system for a ULT freezer. When there is a loss of power or the temperature of the freezer rises to the high alarm set point, the LN2 backup system can be automatically activated to inject LN2 into the chamber to maintain the freezer temperature. The backup system operates on a rechargeable battery when there is a loss of main power.

A-12, adapter for work with tubes which are 12 mm in external diameter.

The ES-20 is a compact bench–top Shaker–Incubator used for mixing of biological liquids as well as for incubation and cultivation of biological liquids according to the operator set program

For the separation and purification of samples of cells, macromolecular proteins, blood, body fluids, DNA/RNA, plasmids, bacteria and viruses.

20 × 0.2 ml microtubes + 12 × 1.5 ml microtubes

Sterile TPP TubeSpin® Bioreactor vessel, 50 ml, with pH and O2 sensor spots, 1 pce.

This product is used in micro centrifugal scenarios (single tube capacity is less than or equal to 2ml)

This product has multiple variants. The options may be chosen on the product page

Cover of a unique sealed structure design provides a two-way guarantee and ensures the sealing property Conical thickened design at the bottom to increase the maximum centrifugal limit Max. centrifugal force: 7000 xg Tolerable temperature range: -80℃-120℃ Clear scale for accurate and convenient data reading Sterile and RNase, DNase, human DNA and Pyrogen Free

This product has multiple variants. The options may be chosen on the product page

The n-Safe Pro cabinets are designed, to provide superior operator and product protection according to EN-12469 and NSF/ANSI 49 The most versatile and popular model in the range, offering high performance, ergonomic design, quiet operation, and touchscreen. Ideal for routine and research labs.  

This product has multiple variants. The options may be chosen on the product page

DICHLOROMETHANE FOR HPLC

SKU: 204181000 Category: Brand:

Methylene chloride

Biochem Chemopharma

DICHLOROMETHANE FOR HPLC
DICHLOROMETHANE FOR HPLC