Assay (TLC) Min 99.0 %
Insoluble matter Passes filter test
Residue on ignition Max 0.05 %
Loss on drying (at 110°C) Max 1 %
Solubility (0.5 M in water; 20°C) Complete,colorless
pH (0.5 M solution in water; 25°C) 5.0 - 6.0
Chloride (Cl) Max 0.005 %
CAS No. | 1135-40-6 |
---|---|
Molecular Formula | C9H19NO3S |
Molecular Weight | 221.3 |
HS Code | 2922.1980 |
Symbol | GHS07 |
Signal Word | Warning |
Hazardous Statement | H302 |
Precaution Statement | P264-P270-P301+P312-P330-P501 |
Safety Statement | 22-24/25 |
Packing | 25 G |
Related Products
Sodium dodecyl sulphate; Dodecyl sodium sulfate; Dodecyl sulfate sodium salt; Lauryl sulfate sodium salt; SDS
Recently Viewed
Consumables
With the tube body made of medical-grade polypropylene and the tube cover made of medical-grade polyethylene, the tubes conform to the USP Class-6 standard; 15ml /50ml conical bottom design, high clarity, black clear scale line on the tube body, and a preset white writing area; Double threaded tube cover, easy to grip for single-handed operation and reliable sealing; Flat cover design; the cover top can be used as a sample information marking area; RNase, DNase Free; Sterilized by gamma rays; sterile and pyrogen-free; Various packaging methods, including sterile racked packing, sterile bag-packed bulk packing, and non-sterile packing, are available.
This product has multiple variants. The options may be chosen on the product pageConsumables
Cover of a unique sealed structure design provides a two-way guarantee and ensures the sealing property Conical thickened design at the bottom to increase the maximum centrifugal limit Max. centrifugal force: 7000 xg Tolerable temperature range: -80℃-120℃ Clear scale for accurate and convenient data reading Sterile and RNase, DNase, human DNA and Pyrogen Free
Dry Block Thermostats
A versatile general purpose system with two removable/interchangeable blocks and a comprehensive specification to suit most dry block heating applications in the laboratory.
This product has multiple variants. The options may be chosen on the product pageSterilization
Typically used for drying and sterilization of laboratory consumables, instruments and samples; as well as heating and curing, drying and dehydration, heat removal, moisture content determination of materials and samples in the fields of medicine, chemical industry, agricultural products as key examples. Other uses include, high temperature heat resistance tests and thermal aging tests of rubber, plastic products and electrical insulation materials. The solution is widely used in medical, enterprise, universities, scientific research institutions, environmental monitoring centers, pharmaceutical, food and drug quality monitoring centers and other related industries.
This product has multiple variants. The options may be chosen on the product pageRotors
Swing-out rotor for conical bottom centrifuge tube. Plastic buckets (POM Kocetal).
Products Best Selling
Sterile TPP TubeSpin® Bioreactor vessel, 50 ml, with pH and O2 sensor spots, 1 pce.
For the separation and purification of samples of cells, macromolecular proteins, blood, body fluids, DNA/RNA, plasmids, bacteria and viruses.
The ES-20 is a compact bench–top Shaker–Incubator used for mixing of biological liquids as well as for incubation and cultivation of biological liquids according to the operator set program
Applicable for storing wholeblood, medicines, biological products and other laboratory products that need to be stored at 4℃. Suitable for the storage of blood and blood articles in areas that have power shortages.
LN2 backup cooling system is an independent refrigeration system for a ULT freezer. When there is a loss of power or the temperature of the freezer rises to the high alarm set point, the LN2 backup system can be automatically activated to inject LN2 into the chamber to maintain the freezer temperature. The backup system operates on a rechargeable battery when there is a loss of main power.
Products Favourite
Applicable for blood stations, hospitals, CDC's, scientific research institutes, chemical industry and other related industries. The -30°C Biomedical Freezer can cryopreserve plasma, biological products, components, materials, and other items that need to be kept at low temperature.
This product has multiple variants. The options may be chosen on the product pageLN2 backup cooling system is an independent refrigeration system for a ULT freezer. When there is a loss of power or the temperature of the freezer rises to the high alarm set point, the LN2 backup system can be automatically activated to inject LN2 into the chamber to maintain the freezer temperature. The backup system operates on a rechargeable battery when there is a loss of main power.
The ES-20 is a compact bench–top Shaker–Incubator used for mixing of biological liquids as well as for incubation and cultivation of biological liquids according to the operator set program
For the separation and purification of samples of cells, macromolecular proteins, blood, body fluids, DNA/RNA, plasmids, bacteria and viruses.
Sterile TPP TubeSpin® Bioreactor vessel, 50 ml, with pH and O2 sensor spots, 1 pce.
CAPS BUFFER FOR BIOCHEMISTRY