The automated liquid handling workstation is designed to provide liquid handling solutions for genomic, cellular, protein and other workflows—in areas such as medical, IVD(In Vitro Diagnosis), drug discovery, biopharma, agriculture and synthetic biology as key examples.

Liquid Transfer

Liquid transfer, such as pipetting from reagent reservoir, Centrifuge tube to 96-well plate, 96-well plate replication etc., mostly in cell culture, compound addition, reagent addition and PCR/qPCR setup.

Continuous Dispensing

Continuous dispensing, such as reagent kit, sub package, reagent addition as key examples.

Serial Dilution

Serial dilutions with changing or unchanging tips, mostly in ELISA, Microbe identification

384-well Liquid Transfer

384-well liquid transfer using special adaptor for 384-well plates.

Precise 96 channel liquid handling with loading or unloading tips automatically

Reliable sealing and versatility between channels ensure precise pipetting.

96 channel pipetting increases speed, 1~20μl head for optimal pipetting as low as 0.5 μL, 5~200μL head suitable for most experiments.

Friendly and powerful operating software

Multiple pipetting modes and parameters are preset. Automatic calculation of the optimal pipetting depth and angle or adjusting the position of pipetting (X/Z axis) as needed.

Free to choose consumables as you need

Consumables can be selected according to the experimental requirements. Automation tips ensure high precision. General tips lower costs. Customization adaptor for non-SBS format consumables.

Small Size

Can be placed in a clean bench or safety cabinet.

Model Net dimensions (W*D*H)(mm) Pipetting range Pipetting precision Plate number
LHW-200S4 600*285*460 5-200μL 200ul separat 5 μl CV< 3%;20μl separat 1μl CV< 3% 4
LHW-200S6 885*285*460 5-200μL 200ul separat 5 μl CV< 3%;20μl separat 1μl CV< 3% 6

Documentation

SKUProductTypeLanguageFile
LHW-200Automatic Liquid Handling WorkstationFlyerEnglishDownload
Dimensions N/A
Model

LHW-200S4, LHW-200S6

Related Products

The system is used to verify the correctness of drug subcontracting and to verify the correctness of drugs packaged by packaging machines based on prescription to ensure the safety of drug distribution. Equipment composition: Equipped with a touch screen for computer; Bag conveying module, smoothing module, vibration module, scanning module, visual module; Equipped with image acquisition device, including light source, high-definition camera, bar code scanner, etc

Recently Viewed

Platforms

Clamp HSC-50

Tight fit clamp 50 ml - Ø50 mm for UP-168

Incubators

HCP-258

The equipment finds extensive use across variety of settings, including the scientific research institutions, university laboratories and production departments, in the realms of environmental conservation, public health and epidemic prevention, agriculture and animal husbandry, drug testing, and aquatic industries. It is highly specialized in cultivation, enabling it to meet the cultivation and preservation of most bacteria, molds, and microorganisms, as well as to serve purposes such as water analysis and biochemical oxygen demand (BOD) determination, and it can also conduct darkroom cultivation of plant tissues.

This product has multiple variants. The options may be chosen on the product page

High-speed mini-centrifuge Microspin 12 Plus is a compact desktop centrifuge designed for biomedical laboratories. Microspin 12 Plus is used for extracting RNA/DNA samples, sedimentation of biological components, biochemical and chemical analysis of microsamples.

Thermo–Shaker TS-100C Smart provides intensive mixing and temperature control of samples in microtest tubes or PCR plate. This model of Thermo–Shaker differs from TS-100 with a possibility of cooling samples down to +4°C and with control up to 7 units from PC via Bluetooth® technology.

Mechanical Pipettes

CAPPTrio Single Channel

CAPPTrio fixed volume pipette is world’s only fixed pipette with multiple interchangeable fixed volumes within one pipette unit! The volume mechanism of this fixed pipette is placed in the small, detachable volume knob on the top of the pipette. CAPPTrio fixed volume pipettes come with 3 fixed volume knobs, allowing you to easily switch from one fixed volume to the other by simply removing the volume knob and putting the other one onto the pipette. CAPPTrio fixed volume micropipette is ideal for routine work. All CAPP fixed volume micropipettes are fully autoclavable expect for the detachable volume knobs. You can easily clean them with commonly used cleaning and disinfection agents.

This product has multiple variants. The options may be chosen on the product page

Biological Safety Cabinet

Standard Biosafety Cabinet-Dual HEPA

Energy efficient Class II microbiological safety cabinet with two DC fans, dual exhaust HEPAs and long lasting LED lights. Suitable for microbiology, biomedicine, biosafety laboratories and other laboratories. It offers three levels of protection – operator, product and environment.

This product has multiple variants. The options may be chosen on the product page

Reagents

CAMPHOR M AR

(±)-Camphor, 1,7,7-Trimethylbicyclo[2.2.1]heptan-2-one

Products Best Selling

Sterile TPP TubeSpin® Bioreactor vessel, 50 ml, with pH and O2 sensor spots, 1 pce.

For the separation and purification of samples of cells, macromolecular proteins, blood, body fluids, DNA/RNA, plasmids, bacteria and viruses.

20 × 0.2 ml microtubes + 12 × 1.5 ml microtubes

The ES-20 is a compact bench–top Shaker–Incubator used for mixing of biological liquids as well as for incubation and cultivation of biological liquids according to the operator set program

Applicable for storing wholeblood, medicines, biological products and other laboratory products that need to be stored at 4℃. Suitable for the storage of blood and blood articles in areas that have power shortages.

LN2 backup cooling system is an independent refrigeration system for a ULT freezer. When there is a loss of power or the temperature of the freezer rises to the high alarm set point, the LN2 backup system can be automatically activated to inject LN2 into the chamber to maintain the freezer temperature. The backup system operates on a rechargeable battery when there is a loss of main power.

A-12, adapter for work with tubes which are 12 mm in external diameter.

Products Favourite

LN2 backup cooling system is an independent refrigeration system for a ULT freezer. When there is a loss of power or the temperature of the freezer rises to the high alarm set point, the LN2 backup system can be automatically activated to inject LN2 into the chamber to maintain the freezer temperature. The backup system operates on a rechargeable battery when there is a loss of main power.

A-12, adapter for work with tubes which are 12 mm in external diameter.

The ES-20 is a compact bench–top Shaker–Incubator used for mixing of biological liquids as well as for incubation and cultivation of biological liquids according to the operator set program

For the separation and purification of samples of cells, macromolecular proteins, blood, body fluids, DNA/RNA, plasmids, bacteria and viruses.

20 × 0.2 ml microtubes + 12 × 1.5 ml microtubes

Sterile TPP TubeSpin® Bioreactor vessel, 50 ml, with pH and O2 sensor spots, 1 pce.

Applicable for blood stations, hospitals, CDC's, scientific research institutes, chemical industry and other related industries. The -30°C Biomedical Freezer can cryopreserve plasma, biological products, components, materials, and other items that need to be kept at low temperature.

This product has multiple variants. The options may be chosen on the product page

Automatic Liquid Handling Workstation

The automated liquid handling workstation is designed to provide liquid handling solutions for genomic, cellular, protein and other workflows—in areas such as medical, IVD(In Vitro Diagnosis), drug discovery, biopharma, agriculture and synthetic biology as key examples.

Haier Biomedical

Automatic Liquid Handling Workstation
Automatic Liquid Handling Workstation