Assay Min. 99.0 %
Weight/ml at 20°C 1.020 - 1.025 g
Ash content Max. 0.02 %
Water (H2O) Max. 0.2 %
Appearance Clear yellow to reddish brown color liquid

CAS No.

62-53-3

Molecular Formula

C6H5NH2

Molecular Weight

93.13

HS Code

2921.4100

Symbol

GHS05, GHS06, GHS08, GHS09

Signal Word

Danger

UN No.

1547

IMCO Class No.

6.1

Hazardous Statement

H301+H311+H331-H410-H351-H318-H341-H317-H372

Precaution Statement

P201-P280-P301+P310-P302+P352-P304+P340-P305+P351+P338-P308+P313-P501

Packing

1 L

Recently Viewed

Reagents

LEAD NITRATE AR

Lead (II) nitrate; Lead dinitrate

Pipette Stands

10 μl filter tips stand

10 μl - 96 pcs in stand

sec-Sodium phosphate; Disodium hydrogen phosphate; Disodium phosphat; Sodium hydrogen phosphate

Centrifuge Adapters

Bucket adapters BA-4/FT

Bucket adapters for 4 conical bottom centrifuge tubes of 15 ml (set of 4 pcs.).

Thermo–Shaker TS-100C Smart provides intensive mixing and temperature control of samples in microtest tubes or PCR plate. This model of Thermo–Shaker differs from TS-100 with a possibility of cooling samples down to +4°C and with control up to 7 units from PC via Bluetooth® technology.

Products Best Selling

Sterile TPP TubeSpin® Bioreactor vessel, 50 ml, with pH and O2 sensor spots, 1 pce.

For the separation and purification of samples of cells, macromolecular proteins, blood, body fluids, DNA/RNA, plasmids, bacteria and viruses.

20 × 0.2 ml microtubes + 12 × 1.5 ml microtubes

The ES-20 is a compact bench–top Shaker–Incubator used for mixing of biological liquids as well as for incubation and cultivation of biological liquids according to the operator set program

Applicable for storing wholeblood, medicines, biological products and other laboratory products that need to be stored at 4℃. Suitable for the storage of blood and blood articles in areas that have power shortages.

LN2 backup cooling system is an independent refrigeration system for a ULT freezer. When there is a loss of power or the temperature of the freezer rises to the high alarm set point, the LN2 backup system can be automatically activated to inject LN2 into the chamber to maintain the freezer temperature. The backup system operates on a rechargeable battery when there is a loss of main power.

A-12, adapter for work with tubes which are 12 mm in external diameter.

Products Favourite

LN2 backup cooling system is an independent refrigeration system for a ULT freezer. When there is a loss of power or the temperature of the freezer rises to the high alarm set point, the LN2 backup system can be automatically activated to inject LN2 into the chamber to maintain the freezer temperature. The backup system operates on a rechargeable battery when there is a loss of main power.

A-12, adapter for work with tubes which are 12 mm in external diameter.

The ES-20 is a compact bench–top Shaker–Incubator used for mixing of biological liquids as well as for incubation and cultivation of biological liquids according to the operator set program

For the separation and purification of samples of cells, macromolecular proteins, blood, body fluids, DNA/RNA, plasmids, bacteria and viruses.

20 × 0.2 ml microtubes + 12 × 1.5 ml microtubes

Sterile TPP TubeSpin® Bioreactor vessel, 50 ml, with pH and O2 sensor spots, 1 pce.

Applicable for blood stations, hospitals, CDC's, scientific research institutes, chemical industry and other related industries. The -30°C Biomedical Freezer can cryopreserve plasma, biological products, components, materials, and other items that need to be kept at low temperature.

This product has multiple variants. The options may be chosen on the product page

ANILINE FOR SYNTHESIS

SKU: 201051000 Category: Brand:

Aminobenzene; Aminophen; Aniline oil; Benzenamine; Benzene,amino; Phenylamine

Biochem Chemopharma

ANILINE FOR SYNTHESIS
ANILINE FOR SYNTHESIS