APPEARANCE REPORT
ASSAY % >= 99
CHLORIDE % <= 0.001
HPLC - UV GRADIENT SUITABILITY PDA (200 - 400 nm) mAU <= 2
IDENTIFICATION PASS/FAIL IN PASS TEST
IONIC IMPURITY - ALUMINUM (Al) ppb <= 20
IONIC IMPURITY - CALCIUM (Ca) ppb <= 50
IONIC IMPURITY - COPPER (Cu) ppb <= 10
IONIC IMPURITY - IRON (Fe) ppb <= 10
IONIC IMPURITY - LEAD (Pb) ppb <= 10
IONIC IMPURITY - MAGNESIUM (Mg) ppb <= 10
IONIC IMPURITY - MANGANESE (Mn) ppb <= 10
IONIC IMPURITY - NICKEL (Ni) ppb <= 10
IONIC IMPURITY - POTASSIUM (K) ppb <= 20
IONIC IMPURITY - SILVER (Ag) ppb <= 10
IONIC IMPURITY - SODIUM (Na) ppb <= 50
IONIC IMPURITY - ZINC (Zn) ppb <= 20
LCMS SUITABILITY - POS. MODE (AS PROPAZINE) PASS/FAIL IN PASS TEST
OPTICAL ABS AT 210 NM ABS. UNITS <= 0.85
OPTICAL ABS AT 220 NM ABS. UNITS <= 0.3
OPTICAL ABS AT 230 NM ABS. UNITS <= 0.05
OPTICAL ABS AT 254 NM ABS. UNITS <= 0.01
OPTICAL ABS AT 280 NM ABS. UNITS <= 0.005
PH OF 0.1% AQUEOUS SOLUTION Inclusive Between 6.0 - 7.0
PROTEASE PASS/FAIL IN NOT DETECTED
RESIDUE AFTER IGNITION % <= 0.005
SULFATE (SO4) % <= 0.005
WATER (H2O) % <= 2
CAS No. | 540-69-2 |
---|---|
Molecular Formula | CH5NO2 |
Molecular Weight | 63.06 |
HS Code | 2915.1200 |
Symbol | GHS07 |
Signal Word | Warning |
Hazardous Statement | H319 |
Precaution Statement | P264-P280-P305+P351+P338-P337+P313 |
Packing | 50 G |
Related Products
3,8-Diamino-5-ethyl-6-phenylphenanthridinium bromide, EtBr, Homidium bromide
Recently Viewed
Automated Solution for Medication Dispensing
The automatic sorting system used in hospital PIVAS (Pharmacy Intravenous Admixture Services) can effectively improve the accuracy of drug dispensing, reduce work intensity, increase work efficiency, ensure medication safety, and enhance pharmaceutical services and hospital management.
Pharmacy Refrigerator
This product is designed to store frozen biomaterials, vaccines, electronic devices and low temperature tests of special materials, in hospitals, epidemic prevention stations, universities, scientific research institutes, electronic chemical industry and other enterprise laboratories.
This product has multiple variants. The options may be chosen on the product pageAllergens
Reveal 3-D for Gluten is Neogen’s new lateral flow gluten test that streamlines qualitative gluten testing and optimizes the users’ experience. This test offers a new testing method for measuring gluten content in both food products and ingredients. This test standardizes the test procedure into a simpler, easy to follow format, which facilitates your training and your process. This test also standardizes the detection limit of gluten, allowing for increased consistency. Combined with our industry-leading time to result, these enhancements allow for real-time decision making and rapid turnaround of product.
Mechanical Pipettes
CAPPSolo multichannel pipettes pack premium features in an affordable package without compromising on quality. These excellent mechanical pipettes would find a home in a variety of labs including academia, diagnostics and research where budgetary constraints often limit the options for procuring high-quality lab equipment. With the new CAPPSolo 8- and 12-channel mechanical pipettes, life science research just got exciting!
This product has multiple variants. The options may be chosen on the product pageReagents
2-Hydroxy-1,2,3-propanetricarboxylic acid monohydrate
Platforms
Universal platform with clamps can accommodate flasks or bottles of different volume sizes. Clamps are not included with platform and need to be ordered separately.
Products Best Selling
Sterile TPP TubeSpin® Bioreactor vessel, 50 ml, with pH and O2 sensor spots, 1 pce.
For the separation and purification of samples of cells, macromolecular proteins, blood, body fluids, DNA/RNA, plasmids, bacteria and viruses.
The ES-20 is a compact bench–top Shaker–Incubator used for mixing of biological liquids as well as for incubation and cultivation of biological liquids according to the operator set program
LN2 backup cooling system is an independent refrigeration system for a ULT freezer. When there is a loss of power or the temperature of the freezer rises to the high alarm set point, the LN2 backup system can be automatically activated to inject LN2 into the chamber to maintain the freezer temperature. The backup system operates on a rechargeable battery when there is a loss of main power.
Applicable for storing wholeblood, medicines, biological products and other laboratory products that need to be stored at 4℃. Suitable for the storage of blood and blood articles in areas that have power shortages.
Products Favourite
LN2 backup cooling system is an independent refrigeration system for a ULT freezer. When there is a loss of power or the temperature of the freezer rises to the high alarm set point, the LN2 backup system can be automatically activated to inject LN2 into the chamber to maintain the freezer temperature. The backup system operates on a rechargeable battery when there is a loss of main power.
The ES-20 is a compact bench–top Shaker–Incubator used for mixing of biological liquids as well as for incubation and cultivation of biological liquids according to the operator set program
For the separation and purification of samples of cells, macromolecular proteins, blood, body fluids, DNA/RNA, plasmids, bacteria and viruses.
Sterile TPP TubeSpin® Bioreactor vessel, 50 ml, with pH and O2 sensor spots, 1 pce.
Applicable for blood stations, hospitals, CDC's, scientific research institutes, chemical industry and other related industries. The -30°C Biomedical Freezer can cryopreserve plasma, biological products, components, materials, and other items that need to be kept at low temperature.
This product has multiple variants. The options may be chosen on the product pageAMMONIUM FORMATE MSCHROM FOR LC-MS CHROMATOGRAPHY
Formic acid ammonium salt