APPEARANCE REPORT
ASSAY % >= 99
CHLORIDE % <= 0.001
HPLC - UV GRADIENT SUITABILITY PDA (200 - 400 nm) mAU <= 2
IDENTIFICATION PASS/FAIL IN PASS TEST
IONIC IMPURITY - ALUMINUM (Al) ppb <= 20
IONIC IMPURITY - CALCIUM (Ca) ppb <= 50
IONIC IMPURITY - COPPER (Cu) ppb <= 10
IONIC IMPURITY - IRON (Fe) ppb <= 10
IONIC IMPURITY - LEAD (Pb) ppb <= 10
IONIC IMPURITY - MAGNESIUM (Mg) ppb <= 10
IONIC IMPURITY - MANGANESE (Mn) ppb <= 10
IONIC IMPURITY - NICKEL (Ni) ppb <= 10
IONIC IMPURITY - POTASSIUM (K) ppb <= 20
IONIC IMPURITY - SILVER (Ag) ppb <= 10
IONIC IMPURITY - SODIUM (Na) ppb <= 50
IONIC IMPURITY - ZINC (Zn) ppb <= 20
LCMS SUITABILITY - POS. MODE (AS PROPAZINE) PASS/FAIL IN PASS TEST
OPTICAL ABS AT 210 NM ABS. UNITS <= 0.85
OPTICAL ABS AT 220 NM ABS. UNITS <= 0.3
OPTICAL ABS AT 230 NM ABS. UNITS <= 0.05
OPTICAL ABS AT 254 NM ABS. UNITS <= 0.01
OPTICAL ABS AT 280 NM ABS. UNITS <= 0.005
PH OF 0.1% AQUEOUS SOLUTION Inclusive Between 6.0 - 7.0
PROTEASE PASS/FAIL IN NOT DETECTED
RESIDUE AFTER IGNITION % <= 0.005
SULFATE (SO4) % <= 0.005
WATER (H2O) % <= 2
CAS No. | 540-69-2 |
---|---|
Molecular Formula | CH5NO2 |
Molecular Weight | 63.06 |
HS Code | 2915.1200 |
Symbol | GHS07 |
Signal Word | Warning |
Hazardous Statement | H319 |
Precaution Statement | P264-P280-P305+P351+P338-P337+P313 |
Packing | 50 G |
Related Products
Recently Viewed
Rockers, Shakers and Rotators
“Sunflower” 3D Mini–Shaker provides adjustable three-dimensional smooth rotation of the platform and is designed for mixing blood samples, for minigel staining and destaining, sample washing, blot hybridization reactions. Mini–Shaker is a compact device with low energy consumption.
Amplification and PCR
COVID-19 is a single-stranded, positive-sense RNA virus that caused a nationwide outbreak of serious respiratory problems across the world. This RNA virus is capable of person-to-person transmission, spreading very rapidly and afecting almost every country. It is genetically highly related to SARS and MERS coronaviruses.
Freeze Dryer
After the samples become freeze-dried preparations, they are more stable, especially for high temperature sensitive drugs, and most of them can be transported and stored at 0-4℃ or even normal temperature after freeze-dried, so the transportation and storage cost and inactivation risk are greatly reduced. Compared with traditional drying methods, the bioactive materials can restore their pre-freeze-dried conformation and biological function after redissolution. Therefore, freeze-drying is the safest method with the least impact on the properties of the drying materials.
Thermo-Shakers
TS-DW Thermo–Shaker is designed for shaking and incubating deep well plates. A multisystem principle, used in the design of the Thermo-Shaker, allows operating it as 3 independent devices: Incubator, Plate shaker and Thermo–Shaker.
Products Best Selling
Sterile TPP TubeSpin® Bioreactor vessel, 50 ml, with pH and O2 sensor spots, 1 pce.
For the separation and purification of samples of cells, macromolecular proteins, blood, body fluids, DNA/RNA, plasmids, bacteria and viruses.
The ES-20 is a compact bench–top Shaker–Incubator used for mixing of biological liquids as well as for incubation and cultivation of biological liquids according to the operator set program
Applicable for storing wholeblood, medicines, biological products and other laboratory products that need to be stored at 4℃. Suitable for the storage of blood and blood articles in areas that have power shortages.
LN2 backup cooling system is an independent refrigeration system for a ULT freezer. When there is a loss of power or the temperature of the freezer rises to the high alarm set point, the LN2 backup system can be automatically activated to inject LN2 into the chamber to maintain the freezer temperature. The backup system operates on a rechargeable battery when there is a loss of main power.
Products Favourite
For the separation and purification of samples of cells, macromolecular proteins, blood, body fluids, DNA/RNA, plasmids, bacteria and viruses.
Sterile TPP TubeSpin® Bioreactor vessel, 50 ml, with pH and O2 sensor spots, 1 pce.
Applicable for blood stations, hospitals, CDC's, scientific research institutes, chemical industry and other related industries. The -30°C Biomedical Freezer can cryopreserve plasma, biological products, components, materials, and other items that need to be kept at low temperature.
This product has multiple variants. The options may be chosen on the product pageLN2 backup cooling system is an independent refrigeration system for a ULT freezer. When there is a loss of power or the temperature of the freezer rises to the high alarm set point, the LN2 backup system can be automatically activated to inject LN2 into the chamber to maintain the freezer temperature. The backup system operates on a rechargeable battery when there is a loss of main power.
The ES-20 is a compact bench–top Shaker–Incubator used for mixing of biological liquids as well as for incubation and cultivation of biological liquids according to the operator set program
AMMONIUM FORMATE MSCHROM FOR LC-MS CHROMATOGRAPHY
Formic acid ammonium salt