APPEARANCE REPORT
ASSAY % >= 99
CHLORIDE % <= 0.001
HPLC - UV GRADIENT SUITABILITY PDA (200 - 400 nm) mAU <= 2
IDENTIFICATION PASS/FAIL IN PASS TEST
IONIC IMPURITY - ALUMINUM (Al) ppb <= 20
IONIC IMPURITY - CALCIUM (Ca) ppb <= 50
IONIC IMPURITY - COPPER (Cu) ppb <= 10
IONIC IMPURITY - IRON (Fe) ppb <= 10
IONIC IMPURITY - LEAD (Pb) ppb <= 10
IONIC IMPURITY - MAGNESIUM (Mg) ppb <= 10
IONIC IMPURITY - MANGANESE (Mn) ppb <= 10
IONIC IMPURITY - NICKEL (Ni) ppb <= 10
IONIC IMPURITY - POTASSIUM (K) ppb <= 20
IONIC IMPURITY - SILVER (Ag) ppb <= 10
IONIC IMPURITY - SODIUM (Na) ppb <= 50
IONIC IMPURITY - ZINC (Zn) ppb <= 20
LCMS SUITABILITY - POS. MODE (AS PROPAZINE) PASS/FAIL IN PASS TEST
OPTICAL ABS AT 210 NM ABS. UNITS <= 0.85
OPTICAL ABS AT 220 NM ABS. UNITS <= 0.3
OPTICAL ABS AT 230 NM ABS. UNITS <= 0.05
OPTICAL ABS AT 254 NM ABS. UNITS <= 0.01
OPTICAL ABS AT 280 NM ABS. UNITS <= 0.005
PH OF 0.1% AQUEOUS SOLUTION Inclusive Between 6.0 - 7.0
PROTEASE PASS/FAIL IN NOT DETECTED
RESIDUE AFTER IGNITION % <= 0.005
SULFATE (SO4) % <= 0.005
WATER (H2O) % <= 2

CAS No.

540-69-2

Molecular Formula

CH5NO2

Molecular Weight

63.06

HS Code

2915.1200

Symbol

GHS07

Signal Word

Warning

Hazardous Statement

H319

Precaution Statement

P264-P280-P305+P351+P338-P337+P313

Packing

50 G

Recently Viewed

S-Bt Smart Biotherm is designed for work in the areas of cell biology (operations with animal cell cultures and tissues), molecular biology (DNA/RNA reaction analysis, hybridization reactions), biotechnology (synthesis of target proteins and other molecules), immunology (synthesis of antibodies and other proteins of immune system).

Citric acid trisodium salt dihydrate

COâ‚‚ Incubator

COâ‚‚ Tube roller CTR-6

CO2 Tube Roller CTR-6 provides regulated rocking and rolling of maximum up to 6 rollers and is designed for use specifically in CO2 incubators. CTR-6 is specifically designed for use in harsh environments such as CO2 and humidity and provides reproducible results for cell culture growth. Possibility to remove rollers makes the unit flexible and allows for performing various procedures and techniques in various cultivation vessels.

BioKits Walnut Assay Kit is used for the detection and quantification of walnut in foods and environmental swabs.

Blocks

Block B-2SL

Block for one deep-well plate Starlab® 96/1200 μl

Plate Thermo–Shakers are designed for shaking and thermostating 2 standard 96–well microplates.

(S)-2-Amino-3-(3-indolyl)propionic acid; L-a-Amino-3-indolepropionic acid

Products Best Selling

Sterile TPP TubeSpin® Bioreactor vessel, 50 ml, with pH and O2 sensor spots, 1 pce.

For the separation and purification of samples of cells, macromolecular proteins, blood, body fluids, DNA/RNA, plasmids, bacteria and viruses.

20 × 0.2 ml microtubes + 12 × 1.5 ml microtubes

The ES-20 is a compact bench–top Shaker–Incubator used for mixing of biological liquids as well as for incubation and cultivation of biological liquids according to the operator set program

Applicable for storing wholeblood, medicines, biological products and other laboratory products that need to be stored at 4℃. Suitable for the storage of blood and blood articles in areas that have power shortages.

LN2 backup cooling system is an independent refrigeration system for a ULT freezer. When there is a loss of power or the temperature of the freezer rises to the high alarm set point, the LN2 backup system can be automatically activated to inject LN2 into the chamber to maintain the freezer temperature. The backup system operates on a rechargeable battery when there is a loss of main power.

A-12, adapter for work with tubes which are 12 mm in external diameter.

Products Favourite

Applicable for blood stations, hospitals, CDC's, scientific research institutes, chemical industry and other related industries. The -30°C Biomedical Freezer can cryopreserve plasma, biological products, components, materials, and other items that need to be kept at low temperature.

This product has multiple variants. The options may be chosen on the product page

LN2 backup cooling system is an independent refrigeration system for a ULT freezer. When there is a loss of power or the temperature of the freezer rises to the high alarm set point, the LN2 backup system can be automatically activated to inject LN2 into the chamber to maintain the freezer temperature. The backup system operates on a rechargeable battery when there is a loss of main power.

A-12, adapter for work with tubes which are 12 mm in external diameter.

The ES-20 is a compact bench–top Shaker–Incubator used for mixing of biological liquids as well as for incubation and cultivation of biological liquids according to the operator set program

For the separation and purification of samples of cells, macromolecular proteins, blood, body fluids, DNA/RNA, plasmids, bacteria and viruses.

20 × 0.2 ml microtubes + 12 × 1.5 ml microtubes

Sterile TPP TubeSpin® Bioreactor vessel, 50 ml, with pH and O2 sensor spots, 1 pce.

AMMONIUM FORMATE MSCHROM FOR LC-MS CHROMATOGRAPHY

SKU: 302370050 Category: Brand:

Formic acid ammonium salt

Biochem Chemopharma

Placeholder
AMMONIUM FORMATE MSCHROM FOR LC-MS CHROMATOGRAPHY