APPEARANCE REPORT
ASSAY % >= 99
CHLORIDE % <= 0.001
HPLC - UV GRADIENT SUITABILITY PDA (200 - 400 nm) mAU <= 2
IDENTIFICATION PASS/FAIL IN PASS TEST
IONIC IMPURITY - ALUMINUM (Al) ppb <= 20
IONIC IMPURITY - CALCIUM (Ca) ppb <= 50
IONIC IMPURITY - COPPER (Cu) ppb <= 10
IONIC IMPURITY - IRON (Fe) ppb <= 10
IONIC IMPURITY - LEAD (Pb) ppb <= 10
IONIC IMPURITY - MAGNESIUM (Mg) ppb <= 10
IONIC IMPURITY - MANGANESE (Mn) ppb <= 10
IONIC IMPURITY - NICKEL (Ni) ppb <= 10
IONIC IMPURITY - POTASSIUM (K) ppb <= 20
IONIC IMPURITY - SILVER (Ag) ppb <= 10
IONIC IMPURITY - SODIUM (Na) ppb <= 50
IONIC IMPURITY - ZINC (Zn) ppb <= 20
LCMS SUITABILITY - POS. MODE (AS PROPAZINE) PASS/FAIL IN PASS TEST
OPTICAL ABS AT 210 NM ABS. UNITS <= 0.85
OPTICAL ABS AT 220 NM ABS. UNITS <= 0.3
OPTICAL ABS AT 230 NM ABS. UNITS <= 0.05
OPTICAL ABS AT 254 NM ABS. UNITS <= 0.01
OPTICAL ABS AT 280 NM ABS. UNITS <= 0.005
PH OF 0.1% AQUEOUS SOLUTION Inclusive Between 6.0 - 7.0
PROTEASE PASS/FAIL IN NOT DETECTED
RESIDUE AFTER IGNITION % <= 0.005
SULFATE (SO4) % <= 0.005
WATER (H2O) % <= 2
CAS No. | 540-69-2 |
---|---|
Molecular Formula | CH5NO2 |
Molecular Weight | 63.06 |
HS Code | 2915.1200 |
Symbol | GHS07 |
Signal Word | Warning |
Hazardous Statement | H319 |
Precaution Statement | P264-P280-P305+P351+P338-P337+P313 |
Packing | 50 G |
Related Products
Sodium dodecyl sulphate; Dodecyl sodium sulfate; Dodecyl sulfate sodium salt; Lauryl sulfate sodium salt; SDS
3,8-Diamino-5-ethyl-6-phenylphenanthridinium bromide, EtBr, Homidium bromide
Recently Viewed
Microcentrifuges - Vortexes
Minicentrifuge-vortex Microspin FV-2400 is specially designed for genetic engineering research (for PCR–diagnostics experiments). Units can be used in microbiological, biochemical, clinical laboratories and industrial biotechnological laboratories. Micro–Spin provides simultaneous mixing and separation of samples, using centrifuge and mixing modules, located on the common spin–module.
o-Cresolphthalein-3',3''-bis-methyleneiminodiacetic acid; o-Cresolphthalexon; Metal phthalein; Phthalein purple; Xylenylphthalein-bisiminodiacetic acid
Reagents
Calcined soda, Carbonic acid disodium salt, Soda ash
Allergens
For use in extracting and testing food samples on Neogen item 8505 Reveal 3-D for Gluten. Sold separately from 8505.
Reagents
Ammonium heptamolybdate tetrahydrate, Molybdic acid ammonium salt tetrahydrate
Pipette Accessories
CAPP offers a wide range of pipette stands. Having CAPPAero single or multichannel pipettes, you can choose between the S-06, which is a carousel stand suitable for up to 6 pipettes, or the C-01 which is a modular stackable pipettor stand.
This product has multiple variants. The options may be chosen on the product pageDrawer
Drawer with non slip silicone mat and soft close function. Can be mounted afterwards.
Products Best Selling
Sterile TPP TubeSpin® Bioreactor vessel, 50 ml, with pH and O2 sensor spots, 1 pce.
For the separation and purification of samples of cells, macromolecular proteins, blood, body fluids, DNA/RNA, plasmids, bacteria and viruses.
The ES-20 is a compact bench–top Shaker–Incubator used for mixing of biological liquids as well as for incubation and cultivation of biological liquids according to the operator set program
Applicable for storing wholeblood, medicines, biological products and other laboratory products that need to be stored at 4℃. Suitable for the storage of blood and blood articles in areas that have power shortages.
LN2 backup cooling system is an independent refrigeration system for a ULT freezer. When there is a loss of power or the temperature of the freezer rises to the high alarm set point, the LN2 backup system can be automatically activated to inject LN2 into the chamber to maintain the freezer temperature. The backup system operates on a rechargeable battery when there is a loss of main power.
Products Favourite
Applicable for blood stations, hospitals, CDC's, scientific research institutes, chemical industry and other related industries. The -30°C Biomedical Freezer can cryopreserve plasma, biological products, components, materials, and other items that need to be kept at low temperature.
This product has multiple variants. The options may be chosen on the product pageLN2 backup cooling system is an independent refrigeration system for a ULT freezer. When there is a loss of power or the temperature of the freezer rises to the high alarm set point, the LN2 backup system can be automatically activated to inject LN2 into the chamber to maintain the freezer temperature. The backup system operates on a rechargeable battery when there is a loss of main power.
The ES-20 is a compact bench–top Shaker–Incubator used for mixing of biological liquids as well as for incubation and cultivation of biological liquids according to the operator set program
For the separation and purification of samples of cells, macromolecular proteins, blood, body fluids, DNA/RNA, plasmids, bacteria and viruses.
Sterile TPP TubeSpin® Bioreactor vessel, 50 ml, with pH and O2 sensor spots, 1 pce.
AMMONIUM FORMATE MSCHROM FOR LC-MS CHROMATOGRAPHY
Formic acid ammonium salt