RESULT NAME UNITS SPECIFICATION
Absorbance @ 210 nm A.U. <= 1.0
Absorbance @ 220 nm A.U. <= 0.2
Absorbance @ 230 nm A.U. <= 0.1
Absorbance @ 254 nm A.U. <= 0.01
Aluminium (Al) ppb = 99.9
Calcium (Ca) ppb <= 10
Colour APHA <= 5
Copper (Cu) ppb <= 5
Identification Must be 'Pass'
Iron (Fe) ppb <= 5
LC Gradient test with PDA (200-400nm) mAU <= 2
LCMS Negative Mode as p-nitrophenol ppb <= 200
LCMS Positive Mode as Propazine ppb <= 200
Lead (Pb) ppb <= 5
Magnesium (Mg) ppb <= 5
Manganese (Mn) ppb <= 5
Nickel (Ni) ppb <= 5
Potassium (K) ppb <= 10
Residue after evaporation (ppm) ppm <= 1.0
Silver (Ag) ppb <= 5
Sodium (Na) ppb <= 50
Titratable acid or base meq/g <= 0.0001
Water % <= 0.05
Zinc (Zn) ppb <= 10
CAS No. | 67-63-0 |
---|---|
Molecular Formula | C3H8O |
Molecular Weight | 60.10 |
HS Code | 2905.1200 |
Symbol | GHS02, GHS07 |
Signal Word | Danger |
UN No. | 1219 |
IMCO Class No. | 3 |
Hazardous Statement | H225-H319-H336 |
Precaution Statement | P210-P280-P304+P340-P305+P351+P338-P370+P378-P403+P233-P235-P501 |
Packing | 1 L |
Related Products
Sodium dodecyl sulphate; Dodecyl sodium sulfate; Dodecyl sulfate sodium salt; Lauryl sulfate sodium salt; SDS
Recently Viewed
Ethylenedinitrilo)tetraacetic acid dipotassium salt, Dipotassium ethylenediaminetetraacetate dihydrate, EDTA dipotassium salt, Edathamil, Potassium ethylenediaminetetraacetate dibasic
Platforms
Flat platform with non-slip silicone mat for Petri dishes, culture flasks, agglutination.
Transport Cooler
Transport Cooler for Biological Products(Passive Cooling)
·Multi-function handle with casters for easy transportation ·Multi dimensional binding of orders and blood, and whole process with cold chain monitoring ·From blood collection vehicle/blood donation house to blood center/blood station from blood center/blood station to hospital
This product has multiple variants. The options may be chosen on the product pageULT Freezers
Haier Biomedical Salvum brand of ULT freezers has been designed to deliver energy savings and reduced carbon footprint. This range uses environmentally safe hydrocarbon refrigerants and high efficiency fan motors to maximize the cooling ability of the system and reduce energy consumption. While providing sample safety, the freezer design makes energy savings possible for laboratories.
This product has multiple variants. The options may be chosen on the product pageReagents
1-Pentadecanecarboxylic acid, C16:0, Cetylic acid, Hexadecanoic acid, NSC 5030, PamOH
Allergens
Reveal® 3-D for Coconut offers results in just 5 minutes and can be used in virtually any environment to screen for coconut in liquid products (like UHT beverages, juices, drink flavours, etc.), clean-in-place rinses and environmental surfaces. The Reveal 3-D line of food allergen tests kits is uniquely designed to guard against over-saturation and false negative results, with results displayed in three visual lines on the lateral flow test strip. A control line assures the test is working properly, and two other lines outline non-detectable, low, and high levels of coconut.
Products Best Selling
Sterile TPP TubeSpin® Bioreactor vessel, 50 ml, with pH and O2 sensor spots, 1 pce.
For the separation and purification of samples of cells, macromolecular proteins, blood, body fluids, DNA/RNA, plasmids, bacteria and viruses.
The ES-20 is a compact bench–top Shaker–Incubator used for mixing of biological liquids as well as for incubation and cultivation of biological liquids according to the operator set program
LN2 backup cooling system is an independent refrigeration system for a ULT freezer. When there is a loss of power or the temperature of the freezer rises to the high alarm set point, the LN2 backup system can be automatically activated to inject LN2 into the chamber to maintain the freezer temperature. The backup system operates on a rechargeable battery when there is a loss of main power.
Applicable for storing wholeblood, medicines, biological products and other laboratory products that need to be stored at 4℃. Suitable for the storage of blood and blood articles in areas that have power shortages.
Products Favourite
LN2 backup cooling system is an independent refrigeration system for a ULT freezer. When there is a loss of power or the temperature of the freezer rises to the high alarm set point, the LN2 backup system can be automatically activated to inject LN2 into the chamber to maintain the freezer temperature. The backup system operates on a rechargeable battery when there is a loss of main power.
The ES-20 is a compact bench–top Shaker–Incubator used for mixing of biological liquids as well as for incubation and cultivation of biological liquids according to the operator set program
For the separation and purification of samples of cells, macromolecular proteins, blood, body fluids, DNA/RNA, plasmids, bacteria and viruses.
Sterile TPP TubeSpin® Bioreactor vessel, 50 ml, with pH and O2 sensor spots, 1 pce.
Applicable for blood stations, hospitals, CDC's, scientific research institutes, chemical industry and other related industries. The -30°C Biomedical Freezer can cryopreserve plasma, biological products, components, materials, and other items that need to be kept at low temperature.
This product has multiple variants. The options may be chosen on the product page2-PROPANOL MSCHROM FOR LC-MS CHROMATOGRAPHY
2-Propanol