RESULT NAME UNITS SPECIFICATION
Absorbance @ 210 nm A.U. <= 1.0
Absorbance @ 220 nm A.U. <= 0.2
Absorbance @ 230 nm A.U. <= 0.1
Absorbance @ 254 nm A.U. <= 0.01
Aluminium (Al) ppb = 99.9
Calcium (Ca) ppb <= 10
Colour APHA <= 5
Copper (Cu) ppb <= 5
Identification Must be 'Pass'
Iron (Fe) ppb <= 5
LC Gradient test with PDA (200-400nm) mAU <= 2
LCMS Negative Mode as p-nitrophenol ppb <= 200
LCMS Positive Mode as Propazine ppb <= 200
Lead (Pb) ppb <= 5
Magnesium (Mg) ppb <= 5
Manganese (Mn) ppb <= 5
Nickel (Ni) ppb <= 5
Potassium (K) ppb <= 10
Residue after evaporation (ppm) ppm <= 1.0
Silver (Ag) ppb <= 5
Sodium (Na) ppb <= 50
Titratable acid or base meq/g <= 0.0001
Water % <= 0.05
Zinc (Zn) ppb <= 10

CAS No.

67-63-0

Molecular Formula

C3H8O

Molecular Weight

60.10

HS Code

2905.1200

Symbol

GHS02, GHS07

Signal Word

Danger

UN No.

1219

IMCO Class No.

3

Hazardous Statement

H225-H319-H336

Precaution Statement

P210-P280-P304+P340-P305+P351+P338-P370+P378-P403+P233-P235-P501

Packing

1 L

Recently Viewed

Liquid Nitrogen Storage Solutions

Liquid Nitrogen Container-Medical Storage Series

Medium Sized Storage Series (Square Racks) features low LN2 consumption and relatively small footprint for medium capacity sample storage. ULT Storage with Extremely Low LN2 Evapouration Loss. Advanced Vacuum Technology and Superinsulation Technology. Compatible for Blood Bag Storage.

This product has multiple variants. The options may be chosen on the product page

Common salt, Halite, Rock salt, Saline, Table salt

Strontium(II) chloride hexahydrate

Mechanical Pipettes

CAPPTrio Single Channel

CAPPTrio fixed volume pipette is world’s only fixed pipette with multiple interchangeable fixed volumes within one pipette unit! The volume mechanism of this fixed pipette is placed in the small, detachable volume knob on the top of the pipette. CAPPTrio fixed volume pipettes come with 3 fixed volume knobs, allowing you to easily switch from one fixed volume to the other by simply removing the volume knob and putting the other one onto the pipette. CAPPTrio fixed volume micropipette is ideal for routine work. All CAPP fixed volume micropipettes are fully autoclavable expect for the detachable volume knobs. You can easily clean them with commonly used cleaning and disinfection agents.

This product has multiple variants. The options may be chosen on the product page

Spark Free Refrigerators and Freezers

Spark Free Refrigerator

Spark free refrigerators are installed typically in many different laboratories and research facilities to store chemical or experimental reagents that are flammable, explosive, evaporative or corrosive. Application Haier spark free refrigerators are ATEX certified in the application range II 3G Ex ic nA II T6, which means the appliances can be found in the whole II zone environment (including II A and II B, II C), a typical environment within many biochemistry laboratories.

This product has multiple variants. The options may be chosen on the product page

Products Best Selling

Sterile TPP TubeSpin® Bioreactor vessel, 50 ml, with pH and O2 sensor spots, 1 pce.

For the separation and purification of samples of cells, macromolecular proteins, blood, body fluids, DNA/RNA, plasmids, bacteria and viruses.

20 × 0.2 ml microtubes + 12 × 1.5 ml microtubes

The ES-20 is a compact bench–top Shaker–Incubator used for mixing of biological liquids as well as for incubation and cultivation of biological liquids according to the operator set program

Applicable for storing wholeblood, medicines, biological products and other laboratory products that need to be stored at 4℃. Suitable for the storage of blood and blood articles in areas that have power shortages.

LN2 backup cooling system is an independent refrigeration system for a ULT freezer. When there is a loss of power or the temperature of the freezer rises to the high alarm set point, the LN2 backup system can be automatically activated to inject LN2 into the chamber to maintain the freezer temperature. The backup system operates on a rechargeable battery when there is a loss of main power.

A-12, adapter for work with tubes which are 12 mm in external diameter.

Products Favourite

Applicable for blood stations, hospitals, CDC's, scientific research institutes, chemical industry and other related industries. The -30°C Biomedical Freezer can cryopreserve plasma, biological products, components, materials, and other items that need to be kept at low temperature.

This product has multiple variants. The options may be chosen on the product page

LN2 backup cooling system is an independent refrigeration system for a ULT freezer. When there is a loss of power or the temperature of the freezer rises to the high alarm set point, the LN2 backup system can be automatically activated to inject LN2 into the chamber to maintain the freezer temperature. The backup system operates on a rechargeable battery when there is a loss of main power.

A-12, adapter for work with tubes which are 12 mm in external diameter.

The ES-20 is a compact bench–top Shaker–Incubator used for mixing of biological liquids as well as for incubation and cultivation of biological liquids according to the operator set program

For the separation and purification of samples of cells, macromolecular proteins, blood, body fluids, DNA/RNA, plasmids, bacteria and viruses.

20 × 0.2 ml microtubes + 12 × 1.5 ml microtubes

Sterile TPP TubeSpin® Bioreactor vessel, 50 ml, with pH and O2 sensor spots, 1 pce.

2-PROPANOL MSCHROM FOR LC-MS CHROMATOGRAPHY

SKU: 216041000 Category: Brand:

2-Propanol

Biochem Chemopharma

2-PROPANOL MSCHROM FOR LC-MS CHROMATOGRAPHY
2-PROPANOL MSCHROM FOR LC-MS CHROMATOGRAPHY