RESULT NAME UNITS SPECIFICATION
Absorbance @ 210 nm A.U. <= 1.0
Absorbance @ 220 nm A.U. <= 0.2
Absorbance @ 230 nm A.U. <= 0.1
Absorbance @ 254 nm A.U. <= 0.01
Aluminium (Al) ppb = 99.9
Calcium (Ca) ppb <= 10
Colour APHA <= 5
Copper (Cu) ppb <= 5
Identification Must be 'Pass'
Iron (Fe) ppb <= 5
LC Gradient test with PDA (200-400nm) mAU <= 2
LCMS Negative Mode as p-nitrophenol ppb <= 200
LCMS Positive Mode as Propazine ppb <= 200
Lead (Pb) ppb <= 5
Magnesium (Mg) ppb <= 5
Manganese (Mn) ppb <= 5
Nickel (Ni) ppb <= 5
Potassium (K) ppb <= 10
Residue after evaporation (ppm) ppm <= 1.0
Silver (Ag) ppb <= 5
Sodium (Na) ppb <= 50
Titratable acid or base meq/g <= 0.0001
Water % <= 0.05
Zinc (Zn) ppb <= 10

CAS No.

67-63-0

Molecular Formula

C3H8O

Molecular Weight

60.10

HS Code

2905.1200

Symbol

GHS02, GHS07

Signal Word

Danger

UN No.

1219

IMCO Class No.

3

Hazardous Statement

H225-H319-H336

Precaution Statement

P210-P280-P304+P340-P305+P351+P338-P370+P378-P403+P233-P235-P501

Packing

1 L

Recently Viewed

Consumables

Centrifuge Tubes

With the tube body made of medical-grade polypropylene and the tube cover made of medical-grade polyethylene, the tubes conform to the USP Class-6 standard; 15ml /50ml conical bottom design, high clarity, black clear scale line on the tube body, and a preset white writing area; Double threaded tube cover, easy to grip for single-handed operation and reliable sealing; Flat cover design; the cover top can be used as a sample information marking area; RNase, DNase Free; Sterilized by gamma rays; sterile and pyrogen-free; Various packaging methods, including sterile racked packing, sterile bag-packed bulk packing, and non-sterile packing, are available.

This product has multiple variants. The options may be chosen on the product page

Platforms

Dimpled mat PDM

Dimpled mat PDM prevents different size tubes from rolling around the platform.

Platforms

Clamp HSC-500

Tight fit clamp 500 ml - Ø105 mm for UP-168.

Biosafety Air - UV - Cleaner Boxes

UV Cleaner–Recirculator UVR-Mi

Operation principle is based on a constant, forced air circulation through recirculator`s chamber in close vicinity to UV lamps, thus ensuring maximal efficiency of disinfection. The inner mirror surface of recirculator chamber reflects ultraviolet rays thereby increasing the density of UV radiation and enhancing the disinfection effect.

4-(2-Hydroxyethyl)piperazine-1-ethanesulfonic acid; N-(2-Hydroxyethyl)piperazine-N'-(2-ethanesulfonic acid)

Wool Grease; Wool Wax; Wool fat

Products Best Selling

Sterile TPP TubeSpin® Bioreactor vessel, 50 ml, with pH and O2 sensor spots, 1 pce.

For the separation and purification of samples of cells, macromolecular proteins, blood, body fluids, DNA/RNA, plasmids, bacteria and viruses.

20 × 0.2 ml microtubes + 12 × 1.5 ml microtubes

The ES-20 is a compact bench–top Shaker–Incubator used for mixing of biological liquids as well as for incubation and cultivation of biological liquids according to the operator set program

LN2 backup cooling system is an independent refrigeration system for a ULT freezer. When there is a loss of power or the temperature of the freezer rises to the high alarm set point, the LN2 backup system can be automatically activated to inject LN2 into the chamber to maintain the freezer temperature. The backup system operates on a rechargeable battery when there is a loss of main power.

Applicable for storing wholeblood, medicines, biological products and other laboratory products that need to be stored at 4℃. Suitable for the storage of blood and blood articles in areas that have power shortages.

A-12, adapter for work with tubes which are 12 mm in external diameter.

Products Favourite

Sterile TPP TubeSpin® Bioreactor vessel, 50 ml, with pH and O2 sensor spots, 1 pce.

Applicable for blood stations, hospitals, CDC's, scientific research institutes, chemical industry and other related industries. The -30°C Biomedical Freezer can cryopreserve plasma, biological products, components, materials, and other items that need to be kept at low temperature.

This product has multiple variants. The options may be chosen on the product page

LN2 backup cooling system is an independent refrigeration system for a ULT freezer. When there is a loss of power or the temperature of the freezer rises to the high alarm set point, the LN2 backup system can be automatically activated to inject LN2 into the chamber to maintain the freezer temperature. The backup system operates on a rechargeable battery when there is a loss of main power.

A-12, adapter for work with tubes which are 12 mm in external diameter.

The ES-20 is a compact bench–top Shaker–Incubator used for mixing of biological liquids as well as for incubation and cultivation of biological liquids according to the operator set program

For the separation and purification of samples of cells, macromolecular proteins, blood, body fluids, DNA/RNA, plasmids, bacteria and viruses.

20 × 0.2 ml microtubes + 12 × 1.5 ml microtubes

2-PROPANOL MSCHROM FOR LC-MS CHROMATOGRAPHY

SKU: 216041000 Category: Brand:

2-Propanol

Biochem Chemopharma

2-PROPANOL MSCHROM FOR LC-MS CHROMATOGRAPHY
2-PROPANOL MSCHROM FOR LC-MS CHROMATOGRAPHY