RESULT NAME UNITS SPECIFICATION
Absorbance @ 210 nm A.U. <= 1.0
Absorbance @ 220 nm A.U. <= 0.2
Absorbance @ 230 nm A.U. <= 0.1
Absorbance @ 254 nm A.U. <= 0.01
Aluminium (Al) ppb = 99.9
Calcium (Ca) ppb <= 10
Colour APHA <= 5
Copper (Cu) ppb <= 5
Identification Must be 'Pass'
Iron (Fe) ppb <= 5
LC Gradient test with PDA (200-400nm) mAU <= 2
LCMS Negative Mode as p-nitrophenol ppb <= 200
LCMS Positive Mode as Propazine ppb <= 200
Lead (Pb) ppb <= 5
Magnesium (Mg) ppb <= 5
Manganese (Mn) ppb <= 5
Nickel (Ni) ppb <= 5
Potassium (K) ppb <= 10
Residue after evaporation (ppm) ppm <= 1.0
Silver (Ag) ppb <= 5
Sodium (Na) ppb <= 50
Titratable acid or base meq/g <= 0.0001
Water % <= 0.05
Zinc (Zn) ppb <= 10

CAS No.

67-63-0

Molecular Formula

C3H8O

Molecular Weight

60.10

HS Code

2905.1200

Symbol

GHS02, GHS07

Signal Word

Danger

UN No.

1219

IMCO Class No.

3

Hazardous Statement

H225-H319-H336

Precaution Statement

P210-P280-P304+P340-P305+P351+P338-P370+P378-P403+P233-P235-P501

Packing

1 L

Recently Viewed

Reagents

L-SERINE LR

(S)-2-Amino-3-hydroxypropionic acid

a-Hydroxy-a-phenylacetophenone, a-Hydroxybenzyl phenyl ketone, 2-Hydroxy-2-phenylacetophenone

Sodium pyrosulfite; Sodium disulfite

Aspirator with trap flask FTA-2i is designed for aspiration or removal of alcohol, buffer and liquid from reaction vessels (e.g. during DNA/RNA purification or other macromolecule reprecipitation techniques).

Bottle Top Dispensers

CAPPForte Bottle Top Dispenser

CAPPForte bottle top dispenser is the ideal choice for handling strong and corrosive chemicals. Made of highly chemical resistant materials, such as PTFE, PFA, Borosilicate and Platinum, CAPPForte bottle top dispenser can be used for processing acids, solvents and bases on standard and sterile applications, as it is also autoclavable at 121° C / 250° F.

This product has multiple variants. The options may be chosen on the product page

Laboratory bench-top centrifuge with refrigeration LMC-4200R provides temperature control of biomaterial during centrifugation. Temperature control of the so-called “cold-shelf” is a gold standard for enzymologists and cell biologists because it ensures conditions necessary for reproducibility of the sample preparation stage. Temperature control absence at this stage can cause unpredictable results. LMC-4200R is a modern centrifuge designed for operation with microtest plates, gel cards and tubes from 10 to 50 ml.

DNA and RNA Purification

Ultrapure water system Labaqua Bio

Labaqua ultrapure systems are multi-purpose water purification systems. The Labaqua systems produce ultrapure and pure water directly from tap water.

This product has multiple variants. The options may be chosen on the product page

THF; Butylene Oxide; Cyclotetramethylene oxide; 1,4-Epoxybutane

Products Best Selling

Sterile TPP TubeSpin® Bioreactor vessel, 50 ml, with pH and O2 sensor spots, 1 pce.

For the separation and purification of samples of cells, macromolecular proteins, blood, body fluids, DNA/RNA, plasmids, bacteria and viruses.

20 × 0.2 ml microtubes + 12 × 1.5 ml microtubes

The ES-20 is a compact bench–top Shaker–Incubator used for mixing of biological liquids as well as for incubation and cultivation of biological liquids according to the operator set program

Applicable for storing wholeblood, medicines, biological products and other laboratory products that need to be stored at 4℃. Suitable for the storage of blood and blood articles in areas that have power shortages.

LN2 backup cooling system is an independent refrigeration system for a ULT freezer. When there is a loss of power or the temperature of the freezer rises to the high alarm set point, the LN2 backup system can be automatically activated to inject LN2 into the chamber to maintain the freezer temperature. The backup system operates on a rechargeable battery when there is a loss of main power.

A-12, adapter for work with tubes which are 12 mm in external diameter.

Products Favourite

Sterile TPP TubeSpin® Bioreactor vessel, 50 ml, with pH and O2 sensor spots, 1 pce.

Applicable for blood stations, hospitals, CDC's, scientific research institutes, chemical industry and other related industries. The -30°C Biomedical Freezer can cryopreserve plasma, biological products, components, materials, and other items that need to be kept at low temperature.

This product has multiple variants. The options may be chosen on the product page

LN2 backup cooling system is an independent refrigeration system for a ULT freezer. When there is a loss of power or the temperature of the freezer rises to the high alarm set point, the LN2 backup system can be automatically activated to inject LN2 into the chamber to maintain the freezer temperature. The backup system operates on a rechargeable battery when there is a loss of main power.

A-12, adapter for work with tubes which are 12 mm in external diameter.

The ES-20 is a compact bench–top Shaker–Incubator used for mixing of biological liquids as well as for incubation and cultivation of biological liquids according to the operator set program

For the separation and purification of samples of cells, macromolecular proteins, blood, body fluids, DNA/RNA, plasmids, bacteria and viruses.

20 × 0.2 ml microtubes + 12 × 1.5 ml microtubes

2-PROPANOL MSCHROM FOR LC-MS CHROMATOGRAPHY

SKU: 216041000 Category: Brand:

2-Propanol

Biochem Chemopharma

2-PROPANOL MSCHROM FOR LC-MS CHROMATOGRAPHY
2-PROPANOL MSCHROM FOR LC-MS CHROMATOGRAPHY