• Accurate and easy-to-use
  • Cost effective microwell format
  • High specificity

Materials Provided

  1. 48 antibody-coated microwells
  2. 48 red-marked transfer wells
  3. 5 yellow-labeled bottles of 0, 5, 10, 20, and 50 ppm gliadin (0, 10, 20, 40 and 100 ppm gluten) controls (0, 12.5, 25, 50, and 125 ng/mL gliadin)
  4. 2 blue-labeled bottles of enzyme-labeled antibody conjugate
  5. 1 green-labeled bottle of K-Blue® Substrate
  6. 1 red-labeled bottle of Red Stop solution
  7. 40 mL of 10 mM PBS-Tween washing reagent in a wide mouth bottle. Each bottle can prepare 1 L in distilled or deionized water (pH 7.4)
  8. 1 foil pouch of 10 mM PBS dry powder containing enough powder to prepare 1 L of dilution solvent
  9. 50 g of extraction additive in 2 specimen cups
  10. Plastic scoop to measure extraction additive

Materials Required But Not Provided

  1. Orbital rotator or shaker to hold 50 cc centrifuge tubes for a 1 g sample, or shaker water bath with clamps adjusted to hold 125 mL (4 oz) extraction bottles for a 2 g sample
  2. Oven or water bath adjustable to 50°C if analyzing heat-processed samples
  3. Scale capable of weighing 1 ± 0.1 g (Neogen item 9427), or scale capable of weighing 0.25 ± 0.01 g if using gliadin cocktail solution (Neogen item 9395)
  4. Pipettor, 50–200 μL adjustable (Neogen item 9276)
  5. Pipettor, 12-channel (Neogen item 9273)
  6. Pipette tips (Neogen item 9410, 9417, 9407)
  7. Three 1 L bottles to prepare washing solution, extract solution, and sample extract dilution solution (Neogen item 9472)
  8. Test tubes to perform sample extract dilution
  9. Timer (Neogen item 8426, 9452)
  10. Microwell reader with a 650 nm filter (Neogen item 9303)
  11. Three reagent boats for 12-channel pipettor (Neogen item 9435)
  12. Microwell strip holder (Neogen item 9402)
  13. Wash bottle (Neogen item 9400)
  14. Paper towels or equivalent absorbent material
  15. Waterproof marker
  16. Distilled or deionized water
  17. Laboratory grade ethanol (190 proof)
  18. Special extraction additive for dark chocolate, cocoa and tannin (Neogen item 8482)

If testing heat treated products:

  1. Gliadin renaturing cocktail solution for heat processed samples (Neogen item 8483, 8483B, 8483S)
Specifications
Brand Veratox®
Analyte Gliadin/Gluten
Platform ELISA
Result Type Quantitative
Limit of Detection 5 ppm gliadin
Testing Time 30.00
Prop 65 Warning
Warning

WARNING: This product can expose you to chemicals including thimerosal, which is known in the State of California to cause birth defects or other reproductive harm. For more information, go to www.P65Warnings.ca.gov.
Quantity per Package 48 tests
Package Weight 0.80 lb

Documentation

SKUProductTypeLanguageFile
8480Veratox® for GliadinMaterial Safety Data SheetEnglishDownload
8480Veratox® for GliadinUser ManualEnglishDownload

Related Products

Reveal 3-D for Gluten is Neogen’s new lateral flow gluten test that streamlines qualitative gluten testing and optimizes the users’ experience. This test offers a new testing method for measuring gluten content in both food products and ingredients. This test standardizes the test procedure into a simpler, easy to follow format, which facilitates your training and your process. This test also standardizes the detection limit of gluten, allowing for increased consistency. Combined with our industry-leading time to result, these enhancements allow for real-time decision making and rapid turnaround of product.

Reveal® 3-D for Soy offers results in just 5 minutes and can be used in virtually any environment to screen environmental swabs and clean-in-place rinses. The Reveal 3-D line of food allergen tests kits is uniquely designed to guard against oversaturation and false negative results, with results displayed in three visual lines on the lateral flow test strip. A control line assures the test is working properly, and two other lines outline nondetectable, low, and high levels of soy.

Reveal® 3-D for Sesame offers results in just five minutes and can be used in virtually any environment to screen environmental swabs and clean-in-place rinses. The Reveal 3-D line of food allergen tests kits is uniquely designed to guard against oversaturation and false negative results, with results displayed in three visual lines on the lateral flow test strip. A control line assures the test is working properly, and two other lines outline nondetectable, low, and high levels of sesame.

The Egg Protein Rapid kit is a qualitative immunochromatographic lateral flow test designed for screening for the presence of egg protein residues in food products, ingredients, clean in place (CIP) final rinse water and environmental swabs. A control line assures the test is working properly, and the other two lines outline nondetectable, low, and high levels of egg protein.

The Gluten Protein Rapid kit is a qualitative immunochromatographic lateral flow test designed for screening for the presence of gluten protein residues in food products, ingredients, clean in place (CIP) final rinse water and environmental swabs. Positive results are visualized by the presence of two lines; the test line and the control line, when gluten protein is present.

Veratox® VIP (Veratox Improvement Platform) for Peanut Allergen offers enhanced quantitative analysis of very low levels of raw and further-processed peanut residues in a wide variety of food products, ingredients, and clean-in-place rinses. This product can also be used to screen environmental swabs.

Veratox® for Soy Allergen is used for the quantitative analysis of soy residue in food products such as cookies, crackers, granola/power bars, ice cream, salad dressings, cereal, liquid products (e.g., juices and milk) and clean-in-place rinses. Can also be used to screen environmental swabs.

The Soy Protein ELISA Kit is a microwell sandwich ELISA, used for the quantitative analysis of low levels of soy residues in food products, ingredients, clean in place (CIP) rinses and environmental swabs in a 96 well format. The quantity of protein in the sample can be extrapolated from the standard curve, constructed from standards of know concentration, and adjusted to consider the sample dilution.

Reveal® 3-D for Coconut offers results in just 5 minutes and can be used in virtually any environment to screen for coconut in liquid products (like UHT beverages, juices, drink flavours, etc.), clean-in-place rinses and environmental surfaces. The Reveal 3-D line of food allergen tests kits is uniquely designed to guard against over-saturation and false negative results, with results displayed in three visual lines on the lateral flow test strip. A control line assures the test is working properly, and two other lines outline non-detectable, low, and high levels of coconut.

Reveal® 3-D for Egg offers results in just 5 minutes and can be used in virtually any environment to screen environmental swabs and clean-in-place rinses. The Reveal 3-D line of food allergen tests kits is uniquely designed to guard against oversaturation and false negative results, with results displayed in three visual lines on the lateral flow test strip. A control line assures the test is working properly, and two other lines outline nondetectable, low, and high levels of egg.

Veratox® for Sesame is used for the quantitative analysis of sesame residue in food products such as spices, bakery products, cereal products, and clean-in-place rinses. It can also be used to screen environmental swabs.

The Egg White Protein ELISA Kit is a microwell sandwich ELISA, used for the quantitative analysis of low levels of egg white residues in food products, ingredients, clean in place (CIP) rinses and environmental swabs in a 96 well format. The quantity of protein in the sample can be extrapolated from the standard curve, constructed from standards of know concentration, and adjusted to consider the sample dilution.

Recently Viewed

Radiation shielded Microbiological Safety Cabinet Class II and Fume Cupboards for handling radioisotopes such as Tc-99. Includes lead protection (1–50 mm), lead display and generator storage.

Benzoic acid sodium salt

Photometers and Densitometers

Photometer DEN-600

DEN-600 is a compact, portable, rechargeable battery powered photometer. DEN-600 comprises of 600 nm wavelength optical system, which enables to apply - 1) OD600 method that estimated total number of cells, 2) McFarland (McF) turbidity measurement method, 3) Bradford protein assay method for protein concentration measurement, 4) other methods that can be adjusted or optimized using 600 nm wavelength.

Liquid Nitrogen Storage Solutions

Liquid Nitrogen Container-Medical Storage Series

Medium Sized Storage Series (Square Racks) features low LN2 consumption and relatively small footprint for medium capacity sample storage. ULT Storage with Extremely Low LN2 Evapouration Loss. Advanced Vacuum Technology and Superinsulation Technology. Compatible for Blood Bag Storage.

This product has multiple variants. The options may be chosen on the product page

Dehydrated Media and Bases

Gelatin Peptone

1-Heptadecanecarboxylic acid; Cetylacetic acid; Octadecanoic acid; Stearophanic acid

Reagents

ANILINE AR

Aminobenzene; Aminophen; Aniline oil; Benzenamine; Benzene,amino; Phenylamine

Tin (II) chloride dihydrate

Products Best Selling

For the separation and purification of samples of cells, macromolecular proteins, blood, body fluids, DNA/RNA, plasmids, bacteria and viruses.

Applicable for storing wholeblood, medicines, biological products and other laboratory products that need to be stored at 4℃. Suitable for the storage of blood and blood articles in areas that have power shortages.

A-12, adapter for work with tubes which are 12 mm in external diameter.

The ES-20 is a compact bench–top Shaker–Incubator used for mixing of biological liquids as well as for incubation and cultivation of biological liquids according to the operator set program

LN2 backup cooling system is an independent refrigeration system for a ULT freezer. When there is a loss of power or the temperature of the freezer rises to the high alarm set point, the LN2 backup system can be automatically activated to inject LN2 into the chamber to maintain the freezer temperature. The backup system operates on a rechargeable battery when there is a loss of main power.

Sterile TPP TubeSpin® Bioreactor vessel, 50 ml, with pH and O2 sensor spots, 1 pce.

20 × 0.2 ml microtubes + 12 × 1.5 ml microtubes

Products Favourite

LN2 backup cooling system is an independent refrigeration system for a ULT freezer. When there is a loss of power or the temperature of the freezer rises to the high alarm set point, the LN2 backup system can be automatically activated to inject LN2 into the chamber to maintain the freezer temperature. The backup system operates on a rechargeable battery when there is a loss of main power.

A-12, adapter for work with tubes which are 12 mm in external diameter.

The ES-20 is a compact bench–top Shaker–Incubator used for mixing of biological liquids as well as for incubation and cultivation of biological liquids according to the operator set program

For the separation and purification of samples of cells, macromolecular proteins, blood, body fluids, DNA/RNA, plasmids, bacteria and viruses.

20 × 0.2 ml microtubes + 12 × 1.5 ml microtubes

Sterile TPP TubeSpin® Bioreactor vessel, 50 ml, with pH and O2 sensor spots, 1 pce.

Applicable for blood stations, hospitals, CDC's, scientific research institutes, chemical industry and other related industries. The -30°C Biomedical Freezer can cryopreserve plasma, biological products, components, materials, and other items that need to be kept at low temperature.

This product has multiple variants. The options may be chosen on the product page

Veratox® for Gliadin

SKU: 8480 Category: Brand:

Veratox for Gliadin is used for the quantitative analysis of prolamins (wheat gliadin, rye secalin, and barley hordein) in ingredients, environmental surfaces, clean-in-place rinses, and finished food products intended to be prolamins (gluten) free. Can also be used to screen environmental swabs.

Neogen

Veratox® for Gliadin
Veratox® for Gliadin